Transcatheter mitral valve implantation using TENDYNE valve for the treatment of residual severe mitral regurgitation post-transcatheter mitral valve edge-to-edge repair: a case report.

Pub Date : 2024-09-23 eCollection Date: 2024-10-01 DOI:10.1093/ehjcr/ytae515
Mohammed Ali Abunab, Bandar Naim Alamri, Muhammad Azam Shah, Halia Zain Alshehri
{"title":"Transcatheter mitral valve implantation using TENDYNE valve for the treatment of residual severe mitral regurgitation post-transcatheter mitral valve edge-to-edge repair: a case report.","authors":"Mohammed Ali Abunab, Bandar Naim Alamri, Muhammad Azam Shah, Halia Zain Alshehri","doi":"10.1093/ehjcr/ytae515","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Functional mitral regurgitation (MR) in patients with heart failure can be treated medically or by transcatheter edge-to-edge repair (TEER) if medical therapy fails. Patients who are not suitable for TEER or surgical intervention might benefit from transcatheter mitral valve implantation using the TENDYNE valve.</p><p><strong>Case summary: </strong>A 58-year-old male with a history of heart failure was admitted frequently with acute heart failure and functional MR, treated medically without significant improvement. He underwent mitral TEER therapy using MitraClip. A few months later, he was admitted with acute decompensated heart failure. Echocardiography showed severe MR with a detached clip from the posterior leaflet. He underwent redo mitral TEER using MitraClip as an option for treating single leaflet device detachment. He was readmitted with the same symptoms and his echocardiography showed detachment of both clips from the posterior leaflet. The patient underwent TMVI using the TENDYNE valve being not suitable for another attempt of mitral TEER. On follow-up, he was asymptomatic and echocardiography showed normal functioning mitral bioprosthesis with a mean gradient of 4 mm/Hg and no paravalvular leak.</p><p><strong>Discussion: </strong>Transcatheter mitral valve implantation using TENDYNE valve is an option for treating patients with functional MR and detached MitraClips.</p>","PeriodicalId":0,"journal":{"name":"","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2024-09-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11463334/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/ehjcr/ytae515","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Functional mitral regurgitation (MR) in patients with heart failure can be treated medically or by transcatheter edge-to-edge repair (TEER) if medical therapy fails. Patients who are not suitable for TEER or surgical intervention might benefit from transcatheter mitral valve implantation using the TENDYNE valve.

Case summary: A 58-year-old male with a history of heart failure was admitted frequently with acute heart failure and functional MR, treated medically without significant improvement. He underwent mitral TEER therapy using MitraClip. A few months later, he was admitted with acute decompensated heart failure. Echocardiography showed severe MR with a detached clip from the posterior leaflet. He underwent redo mitral TEER using MitraClip as an option for treating single leaflet device detachment. He was readmitted with the same symptoms and his echocardiography showed detachment of both clips from the posterior leaflet. The patient underwent TMVI using the TENDYNE valve being not suitable for another attempt of mitral TEER. On follow-up, he was asymptomatic and echocardiography showed normal functioning mitral bioprosthesis with a mean gradient of 4 mm/Hg and no paravalvular leak.

Discussion: Transcatheter mitral valve implantation using TENDYNE valve is an option for treating patients with functional MR and detached MitraClips.

分享
查看原文
使用 TENDYNE 瓣膜进行经导管二尖瓣植入术,治疗经导管二尖瓣边缘对边缘修复术后残余的严重二尖瓣反流:病例报告。
背景:心力衰竭患者的功能性二尖瓣反流(MR)可通过药物治疗,或在药物治疗无效时通过经导管边缘到边缘修补术(TEER)治疗。病例摘要:一名有心力衰竭病史的 58 岁男性因急性心力衰竭和功能性二尖瓣反流频繁入院,经药物治疗无明显改善。他使用 MitraClip 接受了二尖瓣 TEER 治疗。几个月后,他因急性失代偿性心力衰竭入院。超声心动图显示他有严重的 MR,且后叶夹脱落。他接受了重做二尖瓣 TEER,使用 MitraClip 作为治疗单叶装置脱落的一种选择。他因同样的症状再次入院,超声心动图显示两个夹子都从后叶脱落。由于不适合再次尝试二尖瓣 TEER,患者接受了使用 TENDYNE 瓣膜的二尖瓣置换术。随访时,他没有任何症状,超声心动图显示二尖瓣生物瓣功能正常,平均梯度为4毫米/汞柱,无瓣旁漏:讨论:使用TENDYNE瓣膜进行经导管二尖瓣植入术是治疗功能性MR和MitraClips脱落患者的一种选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信