Kayla Shine, Rachael Cowherd, Alexandra Rowin, Raksha Soora, Michelle Meglin
{"title":"Validity of Endometrial Cavity Length on 3D Pelvic Ultrasound before Endometrial Ablation.","authors":"Kayla Shine, Rachael Cowherd, Alexandra Rowin, Raksha Soora, Michelle Meglin","doi":"10.14423/SMJ.0000000000001736","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>This study aimed to compare endometrial cavity length measurements obtained by preoperative three-dimensional (3D) reconstruction of coronal images on pelvic ultrasound with intraoperative endometrial cavity measurements obtained in advance of Minerva endometrial ablation.</p><p><strong>Methods: </strong>This was a retrospective cohort study of 41 individuals who underwent a Minerva endometrial ablation between August 1, 2018 and March 15, 2022 at a single academic medical center. Patients were excluded if they had an in-clinic ablation or no ultrasound with 3D uterine volume within 180 days before surgery. Physician sonologists measured the endometrial cavity length using 3D coronal reconstruction of the cavity. Two measurements were obtained by separate physicians who were blinded to intraoperative values. Intraoperative endometrial cavity lengths were obtained from operative reports. A Bland-Altman plot was used to evaluate the agreement of intraoperative and ultrasound measurements.</p><p><strong>Results: </strong>The mean intraoperative endometrial cavity length (50.7 ± 7.8 mm) was greater than the mean endometrial cavity length by 3D coronal reconstruction of pelvic ultrasound (36.1 ± 6.2 mm, <i>P</i> < 0.0001). The average difference between intraoperative and ultrasound measurements of cavity length was 14.6 ± 9.0 mm. The agreement between measurements was poor (Lin's concordance correlation coefficient 0.06). Using a Bland-Altman plot, the limits of agreement (-3.1 to 32 mm) exceeded the a priori acceptable limits of agreement (-10 to 10 mm).</p><p><strong>Conclusions: </strong>Our findings suggest that preoperative coronal endometrial cavity length measurements by ultrasound are not a valid substitute for intraoperative measurements before Minerva ablation.</p>","PeriodicalId":22043,"journal":{"name":"Southern Medical Journal","volume":"117 10","pages":"599-602"},"PeriodicalIF":1.0000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Southern Medical Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.14423/SMJ.0000000000001736","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: This study aimed to compare endometrial cavity length measurements obtained by preoperative three-dimensional (3D) reconstruction of coronal images on pelvic ultrasound with intraoperative endometrial cavity measurements obtained in advance of Minerva endometrial ablation.
Methods: This was a retrospective cohort study of 41 individuals who underwent a Minerva endometrial ablation between August 1, 2018 and March 15, 2022 at a single academic medical center. Patients were excluded if they had an in-clinic ablation or no ultrasound with 3D uterine volume within 180 days before surgery. Physician sonologists measured the endometrial cavity length using 3D coronal reconstruction of the cavity. Two measurements were obtained by separate physicians who were blinded to intraoperative values. Intraoperative endometrial cavity lengths were obtained from operative reports. A Bland-Altman plot was used to evaluate the agreement of intraoperative and ultrasound measurements.
Results: The mean intraoperative endometrial cavity length (50.7 ± 7.8 mm) was greater than the mean endometrial cavity length by 3D coronal reconstruction of pelvic ultrasound (36.1 ± 6.2 mm, P < 0.0001). The average difference between intraoperative and ultrasound measurements of cavity length was 14.6 ± 9.0 mm. The agreement between measurements was poor (Lin's concordance correlation coefficient 0.06). Using a Bland-Altman plot, the limits of agreement (-3.1 to 32 mm) exceeded the a priori acceptable limits of agreement (-10 to 10 mm).
Conclusions: Our findings suggest that preoperative coronal endometrial cavity length measurements by ultrasound are not a valid substitute for intraoperative measurements before Minerva ablation.
期刊介绍:
As the official journal of the Birmingham, Alabama-based Southern Medical Association (SMA), the Southern Medical Journal (SMJ) has for more than 100 years provided the latest clinical information in areas that affect patients'' daily lives. Now delivered to individuals exclusively online, the SMJ has a multidisciplinary focus that covers a broad range of topics relevant to physicians and other healthcare specialists in all relevant aspects of the profession, including medicine and medical specialties, surgery and surgery specialties; child and maternal health; mental health; emergency and disaster medicine; public health and environmental medicine; bioethics and medical education; and quality health care, patient safety, and best practices. Each month, articles span the spectrum of medical topics, providing timely, up-to-the-minute information for both primary care physicians and specialists. Contributors include leaders in the healthcare field from across the country and around the world. The SMJ enables physicians to provide the best possible care to patients in this age of rapidly changing modern medicine.