{"title":"Impact of landmark crater creation on improving accuracy of pedicle screw insertion in robot-assisted scoliosis surgery.","authors":"Hiroki Oba, Shota Ikegami, Masashi Uehara, Terue Hatakenaka, Yoshinari Miyaoka, Daisuke Kurogochi, Takuma Fukuzawa, Shinji Sasao, Keisuke Shigenobu, Fumiaki Makiyama, Michihiko Koseki, Masashi Neo, Jun Takahashi","doi":"10.1007/s00586-024-08506-0","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study evaluated the impact of the Landmark Crater (LC) method on pedicle perforation rates in robot-guided surgery for pediatric scoliosis for each pedicle diameter.</p><p><strong>Methods: </strong>Seventy-six scoliosis patients underwent robot-assisted posterior spinal fusion. The cohort consisted of 19 male and 57 female patients, with a mean ± standard deviation age of 17.5 ± 7.7 years and a preoperative Cobb angle of 57.0 ± 18.5°. The LC method is a method in which craters that serves as a landmark are created in advance at the planned PS insertion site of all pedicles within the intraoperative CT imaging area. The patients were divided into the LC group, in which PS insertion was performed using the LC method, and the control group using the conventional PS insertion method. Overall and pedicle perforation rates for each pedicle outer diameter were compared between the groups by Fisher's exact test.</p><p><strong>Results: </strong>The LC group exhibited a significantly lower pedicle major perforation rate than did the control group (2.7% vs. 6.2%, P = 0.001). The perforation rates in pedicles with a pedicle outer diameter > 6 mm, 4-6 mm, 2-4 mm, and < 2 mm were 0.61%, 1.6%, 5.1%, and 21%, in the LC group and 0.75%, 4.1%, 12%, and 50% in the control group, respectively.</p><p><strong>Conclusion: </strong>In robot-assisted surgery for pediatric scoliosis, the LC method enabled significantly lower pedicle perforation rates over the conventional method. Both the LC and conventional methods exhibited higher perforation rates for smaller pedicle diameters.</p>","PeriodicalId":12323,"journal":{"name":"European Spine Journal","volume":" ","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2024-10-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Spine Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00586-024-08506-0","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: This study evaluated the impact of the Landmark Crater (LC) method on pedicle perforation rates in robot-guided surgery for pediatric scoliosis for each pedicle diameter.
Methods: Seventy-six scoliosis patients underwent robot-assisted posterior spinal fusion. The cohort consisted of 19 male and 57 female patients, with a mean ± standard deviation age of 17.5 ± 7.7 years and a preoperative Cobb angle of 57.0 ± 18.5°. The LC method is a method in which craters that serves as a landmark are created in advance at the planned PS insertion site of all pedicles within the intraoperative CT imaging area. The patients were divided into the LC group, in which PS insertion was performed using the LC method, and the control group using the conventional PS insertion method. Overall and pedicle perforation rates for each pedicle outer diameter were compared between the groups by Fisher's exact test.
Results: The LC group exhibited a significantly lower pedicle major perforation rate than did the control group (2.7% vs. 6.2%, P = 0.001). The perforation rates in pedicles with a pedicle outer diameter > 6 mm, 4-6 mm, 2-4 mm, and < 2 mm were 0.61%, 1.6%, 5.1%, and 21%, in the LC group and 0.75%, 4.1%, 12%, and 50% in the control group, respectively.
Conclusion: In robot-assisted surgery for pediatric scoliosis, the LC method enabled significantly lower pedicle perforation rates over the conventional method. Both the LC and conventional methods exhibited higher perforation rates for smaller pedicle diameters.
期刊介绍:
"European Spine Journal" is a publication founded in response to the increasing trend toward specialization in spinal surgery and spinal pathology in general. The Journal is devoted to all spine related disciplines, including functional and surgical anatomy of the spine, biomechanics and pathophysiology, diagnostic procedures, and neurology, surgery and outcomes. The aim of "European Spine Journal" is to support the further development of highly innovative spine treatments including but not restricted to surgery and to provide an integrated and balanced view of diagnostic, research and treatment procedures as well as outcomes that will enhance effective collaboration among specialists worldwide. The “European Spine Journal” also participates in education by means of videos, interactive meetings and the endorsement of educative efforts.
Official publication of EUROSPINE, The Spine Society of Europe