Mohammad Alomari, Ishaq Wadiwala, Steven Bowers, Enrique F Elli, Mathew Thomas
{"title":"Oxygen Saturation Endoscopic Imaging as a Novel Alternative to Assess Tissue Perfusion During Esophagectomy.","authors":"Mohammad Alomari, Ishaq Wadiwala, Steven Bowers, Enrique F Elli, Mathew Thomas","doi":"10.1177/15533506241290071","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Assessment of gastric conduit perfusion during esophagectomy is crucial to determine its viability and identify the optimal site for anastomosis. Indocyanine green (ICG) fluorescence imaging is commonly used for this purpose, but it is contraindicated in patients with hypersensitivity to ICG, iodine, or shellfish. Oxygen saturation endoscopic imaging (OXEI) is a newer, non-pharmacologic technique for assessing perfusion. We report our experience with OXEI in 3 esophagectomy patients who had contraindications to ICG.</p><p><strong>Methods: </strong>All 3 patients underwent robot-assisted esophagectomies. None of the conduits had ischemic areas identified by white light. Using a 5 mm laparoscopic specialized camera (ELUXEO Vision, FUJIFILM Healthcare Americas Corp., USA), OXEI was deployed for intracorporeal assessment of gastric conduit perfusion after pull-up into the chest. Postoperative outcomes including anastomotic leaks and complications were recorded.</p><p><strong>Results: </strong>In two patients, OXEI revealed ischemic zones, which were resected to ensure optimal conduit viability. In the remaining patient, OXEI indicated robust vascularity throughout the conduit. All three patients experienced uneventful postoperative courses and were discharged within 10 days. There were no instances of anastomotic leaks or other major complications.</p><p><strong>Conclusion: </strong>In our experience, OXEI is a viable method for intraoperative assessment of gastric conduit perfusion in patients with contraindications to ICG. Prospective studies are needed to validate its efficacy in preventing anastomotic complications and to compare it with other methods of perfusion assessment including gross visual and ICG dye in a larger patient population.</p>","PeriodicalId":22095,"journal":{"name":"Surgical Innovation","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Surgical Innovation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15533506241290071","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/10/3 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Assessment of gastric conduit perfusion during esophagectomy is crucial to determine its viability and identify the optimal site for anastomosis. Indocyanine green (ICG) fluorescence imaging is commonly used for this purpose, but it is contraindicated in patients with hypersensitivity to ICG, iodine, or shellfish. Oxygen saturation endoscopic imaging (OXEI) is a newer, non-pharmacologic technique for assessing perfusion. We report our experience with OXEI in 3 esophagectomy patients who had contraindications to ICG.
Methods: All 3 patients underwent robot-assisted esophagectomies. None of the conduits had ischemic areas identified by white light. Using a 5 mm laparoscopic specialized camera (ELUXEO Vision, FUJIFILM Healthcare Americas Corp., USA), OXEI was deployed for intracorporeal assessment of gastric conduit perfusion after pull-up into the chest. Postoperative outcomes including anastomotic leaks and complications were recorded.
Results: In two patients, OXEI revealed ischemic zones, which were resected to ensure optimal conduit viability. In the remaining patient, OXEI indicated robust vascularity throughout the conduit. All three patients experienced uneventful postoperative courses and were discharged within 10 days. There were no instances of anastomotic leaks or other major complications.
Conclusion: In our experience, OXEI is a viable method for intraoperative assessment of gastric conduit perfusion in patients with contraindications to ICG. Prospective studies are needed to validate its efficacy in preventing anastomotic complications and to compare it with other methods of perfusion assessment including gross visual and ICG dye in a larger patient population.
期刊介绍:
Surgical Innovation (SRI) is a peer-reviewed bi-monthly journal focusing on minimally invasive surgical techniques, new instruments such as laparoscopes and endoscopes, and new technologies. SRI prepares surgeons to think and work in "the operating room of the future" through learning new techniques, understanding and adapting to new technologies, maintaining surgical competencies, and applying surgical outcomes data to their practices. This journal is a member of the Committee on Publication Ethics (COPE).