Phelipi N Schuck, Xiuyuan H Wang, Emily B Tanzi, Sally Xie, Yi Li, Sadek A Nehmeh
{"title":"Reproducibility of [<sup>18</sup>F]MK-6240 kinetics in brain studies with shortened dynamic PET protocol in healthy/cognitively normal subjects.","authors":"Phelipi N Schuck, Xiuyuan H Wang, Emily B Tanzi, Sally Xie, Yi Li, Sadek A Nehmeh","doi":"10.1186/s40658-024-00679-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>[<sup>18</sup>F]MK-6240 is a neurofibrillary tangles PET radiotracer that has been broadly used in aging and Alzheimer's disease (AD) studies. Majority of [<sup>18</sup>F]MK-6240 PET studies use dynamic acquisitions longer than 60 min to assess the tracer kinetic parameters. As of today, no consensus has been established on the optimum dynamic PET scan time. In this study, we assess the reproducibility of [<sup>18</sup>F]MK-6240 quantitative metrics using shortest dynamic PET protocols in cognitively normal subjects. PET metrics were measured through two-tissue compartment model (2TCM) and Logan model to estimate VT and DVR, as well as SUVR from 90 to 120 min (SUVR<sub>90 - 120 min</sub>) post-tracer injection for brain regions. 2TCM was carried out using the 120 min dynamic coffee break dataset (first scan from 0 to 60 min p.i., second scan from 90 to 120 min p.i.) and then repeated after stepwise shortening it by 5 min. The dynamic scan length that reproduced the 120 min dynamic scans-based VT to within 10% error was defined as the shortest acquisition time (SAT). The SAT SUVR<sub>90 - 120 min</sub> was deduced from the SAT dataset by extrapolation of each image pixel time-activity curve to 120 min. The reproducibility of the 120 min dynamic scans-based VT<sub>2TCM</sub>, DVR<sub>2TCM</sub>, DVR<sub>Logan</sub>, and SUVR using the SAT was assessed using Passing-Bablock analysis. The limits of reproducibility of each PET metrics were determined using Bland-Altman analysis.</p><p><strong>Results: </strong>A dynamic SAT of 40 min yielded < 10% error in [<sup>18</sup>F]MK-6240 VT<sub>2TCM</sub>'s for all brain regions, compared to those measured using the 120 min datasets. SAT-based analysis did not show statistically significant systemic or proportional biases in VT<sub>2TCM</sub>, DVR<sub>2TCM</sub>, DVR<sub>Logan</sub>, or SUVR compared to those deduced from the full dynamic dataset of 120 min. A mean difference between the 120 min- and SAT-based analysis of less than 4%, 10%, 15%, and 20% existed in the VT<sub>2TCM</sub>, DVR<sub>2TCM</sub>, DVR<sub>Logan</sub>, and SUVR respectively.</p><p><strong>Conclusion: </strong>Kinetic modeling of [<sup>18</sup>F]MK-6240 PET can be accurately performed using dynamic scan times as short as 40 min. This can facilitate studies with [<sup>18</sup>F]MK-6240 PET and improve patients accrual. Further work would be necessary to confirm the reproducibility of these results for patients in dementia spectra.</p>","PeriodicalId":11559,"journal":{"name":"EJNMMI Physics","volume":"11 1","pages":"79"},"PeriodicalIF":3.0000,"publicationDate":"2024-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11436579/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"EJNMMI Physics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40658-024-00679-3","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
Background: [18F]MK-6240 is a neurofibrillary tangles PET radiotracer that has been broadly used in aging and Alzheimer's disease (AD) studies. Majority of [18F]MK-6240 PET studies use dynamic acquisitions longer than 60 min to assess the tracer kinetic parameters. As of today, no consensus has been established on the optimum dynamic PET scan time. In this study, we assess the reproducibility of [18F]MK-6240 quantitative metrics using shortest dynamic PET protocols in cognitively normal subjects. PET metrics were measured through two-tissue compartment model (2TCM) and Logan model to estimate VT and DVR, as well as SUVR from 90 to 120 min (SUVR90 - 120 min) post-tracer injection for brain regions. 2TCM was carried out using the 120 min dynamic coffee break dataset (first scan from 0 to 60 min p.i., second scan from 90 to 120 min p.i.) and then repeated after stepwise shortening it by 5 min. The dynamic scan length that reproduced the 120 min dynamic scans-based VT to within 10% error was defined as the shortest acquisition time (SAT). The SAT SUVR90 - 120 min was deduced from the SAT dataset by extrapolation of each image pixel time-activity curve to 120 min. The reproducibility of the 120 min dynamic scans-based VT2TCM, DVR2TCM, DVRLogan, and SUVR using the SAT was assessed using Passing-Bablock analysis. The limits of reproducibility of each PET metrics were determined using Bland-Altman analysis.
Results: A dynamic SAT of 40 min yielded < 10% error in [18F]MK-6240 VT2TCM's for all brain regions, compared to those measured using the 120 min datasets. SAT-based analysis did not show statistically significant systemic or proportional biases in VT2TCM, DVR2TCM, DVRLogan, or SUVR compared to those deduced from the full dynamic dataset of 120 min. A mean difference between the 120 min- and SAT-based analysis of less than 4%, 10%, 15%, and 20% existed in the VT2TCM, DVR2TCM, DVRLogan, and SUVR respectively.
Conclusion: Kinetic modeling of [18F]MK-6240 PET can be accurately performed using dynamic scan times as short as 40 min. This can facilitate studies with [18F]MK-6240 PET and improve patients accrual. Further work would be necessary to confirm the reproducibility of these results for patients in dementia spectra.
期刊介绍:
EJNMMI Physics is an international platform for scientists, users and adopters of nuclear medicine with a particular interest in physics matters. As a companion journal to the European Journal of Nuclear Medicine and Molecular Imaging, this journal has a multi-disciplinary approach and welcomes original materials and studies with a focus on applied physics and mathematics as well as imaging systems engineering and prototyping in nuclear medicine. This includes physics-driven approaches or algorithms supported by physics that foster early clinical adoption of nuclear medicine imaging and therapy.