X.L. Zhang , Z.Y.H. He , Z.F. Cheng , W. Yan , Y.B. Dong , Y. Liu , W. Deng , B.Z. Fu , Z.B. Shi , Y.P. Zhang , Y.J. Shi
{"title":"X-ray imaging crystal spectrometer (XICS) diagnostic on the HL-3 tokamak","authors":"X.L. Zhang , Z.Y.H. He , Z.F. Cheng , W. Yan , Y.B. Dong , Y. Liu , W. Deng , B.Z. Fu , Z.B. Shi , Y.P. Zhang , Y.J. Shi","doi":"10.1016/j.fusengdes.2024.114674","DOIUrl":null,"url":null,"abstract":"<div><div>The construction of an X-ray imaging crystal spectrometer (XICS) diagnostic system on the HL-3 tokamak plays a crucial role in measuring core plasma parameter profiles, including ion temperature, electron temperature, rotational velocity, and impurity radiation profiles. This diagnostic system has been specifically designed to provide detailed and accurate data essential for understanding the behavior and characteristics of tokamak plasma. The resonance spectral line (<em>w</em> line of Ar XVII at 3.9494 Å) and its satellites of helium-like argon ions were chosen on the basis of the HL-3 parameter range. A spherically bent quartz crystal (1012) with a lattice constant of 2d = 4.562 Å, a curvature radius of Rc = 3.0 m, and a size of 10 cm (high) × 5 cm (wide) was mounted on an adjustable displacement platform in the XICS system. The position was adjusted in three dimensions (vertical, inclined, rotation) to effectively record the spectra of the helium-like argon ions. The XICS has a tangential angle of 49° for the toroidal direction in the magnetic axis. This layout accounts for 65.6 % of the toroidal rotation velocity component. The XICS system was set at an 11° poloidal angle in the mid-plane to cover a plasma range of 10 cm above to 50 cm below the mid-plane, which corresponds to the <em>q</em> = 1 surface of the HL-3 plasma (elongation κ > 1.8). This XICS layout produced a spectrum with poloidal and toroidal rotational contributions, requiring decoupling through data processing. In general, because the contribution of the poloidal rotation velocity is much smaller than that of the toroidal rotation velocity, it can be ignored. The XICS system offers a spatial resolution of ∼1.5 cm and a temporal resolution of 5–10 ms on the basis of a high-performance PILATUS3 × 900 K detector. The spectral resolution is <span><math><mrow><mi>λ</mi><mo>/</mo><mstyle><mi>Δ</mi></mstyle><mi>λ</mi><mo>∼</mo><mn>4</mn><mspace></mspace><mo>×</mo><msup><mn>10</mn><mn>4</mn></msup></mrow></math></span>, which satisfies the experimental measurement requirements. Preliminary results of ion and electron temperature profiles were obtained for the HL-3 tokamak.</div></div>","PeriodicalId":55133,"journal":{"name":"Fusion Engineering and Design","volume":"208 ","pages":"Article 114674"},"PeriodicalIF":1.9000,"publicationDate":"2024-09-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fusion Engineering and Design","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0920379624005258","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"NUCLEAR SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
The construction of an X-ray imaging crystal spectrometer (XICS) diagnostic system on the HL-3 tokamak plays a crucial role in measuring core plasma parameter profiles, including ion temperature, electron temperature, rotational velocity, and impurity radiation profiles. This diagnostic system has been specifically designed to provide detailed and accurate data essential for understanding the behavior and characteristics of tokamak plasma. The resonance spectral line (w line of Ar XVII at 3.9494 Å) and its satellites of helium-like argon ions were chosen on the basis of the HL-3 parameter range. A spherically bent quartz crystal (1012) with a lattice constant of 2d = 4.562 Å, a curvature radius of Rc = 3.0 m, and a size of 10 cm (high) × 5 cm (wide) was mounted on an adjustable displacement platform in the XICS system. The position was adjusted in three dimensions (vertical, inclined, rotation) to effectively record the spectra of the helium-like argon ions. The XICS has a tangential angle of 49° for the toroidal direction in the magnetic axis. This layout accounts for 65.6 % of the toroidal rotation velocity component. The XICS system was set at an 11° poloidal angle in the mid-plane to cover a plasma range of 10 cm above to 50 cm below the mid-plane, which corresponds to the q = 1 surface of the HL-3 plasma (elongation κ > 1.8). This XICS layout produced a spectrum with poloidal and toroidal rotational contributions, requiring decoupling through data processing. In general, because the contribution of the poloidal rotation velocity is much smaller than that of the toroidal rotation velocity, it can be ignored. The XICS system offers a spatial resolution of ∼1.5 cm and a temporal resolution of 5–10 ms on the basis of a high-performance PILATUS3 × 900 K detector. The spectral resolution is , which satisfies the experimental measurement requirements. Preliminary results of ion and electron temperature profiles were obtained for the HL-3 tokamak.
期刊介绍:
The journal accepts papers about experiments (both plasma and technology), theory, models, methods, and designs in areas relating to technology, engineering, and applied science aspects of magnetic and inertial fusion energy. Specific areas of interest include: MFE and IFE design studies for experiments and reactors; fusion nuclear technologies and materials, including blankets and shields; analysis of reactor plasmas; plasma heating, fuelling, and vacuum systems; drivers, targets, and special technologies for IFE, controls and diagnostics; fuel cycle analysis and tritium reprocessing and handling; operations and remote maintenance of reactors; safety, decommissioning, and waste management; economic and environmental analysis of components and systems.