Catherine Ratliff, Andrew Barton, Jan Hitchcock, Mikel Gray
{"title":"Assessing and Managing Medical Adhesive-Related Skin Injury in Patients with a Peripherally Inserted Central Catheter: A Case Series.","authors":"Catherine Ratliff, Andrew Barton, Jan Hitchcock, Mikel Gray","doi":"10.1097/WON.0000000000001117","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Medical adhesive-related skin injuries (MARSIs) are prevalent adverse effects associated with use of medical devices and increasingly recognized as potentially avoidable. Despite advances in preventive measures, MARSI events still occur, and individualized care must be designed to meet patient needs.</p><p><strong>Cases: </strong>This article describes three cases where skin injuries occurred because of application, removal, and ongoing use of a medical adhesive device; all three cases occurred underneath dressings used to secure and protect the skin adjacent to a peripherally inserted central catheter (PICC). The first case describes evaluation and management of a skin tear in an elderly female with multiple comorbid conditions, and Case 2 describes assessment and care of contact irritant dermatitis occurring under a PICC dressing. In both cases, specialist nurses with knowledge of MARSI assessed and managed the skin underneath the medical adhesive device in a manner that allowed maintenance of the PICC and continuation of therapy. In contrast, Case 3 describes a female with irritant contact dermatitis underneath a PICC dressing that was responding to care by the nurse specialists of a vascular access team. In this case, the patient presented to their facility's emergency department with severe itching. The vascular access team initially was not consulted, and the PICC line was removed, although inspection revealed dry skin without signs of infection.</p><p><strong>Conclusions: </strong>Medical adhesive-related skin injury is a clinically relevant and useful construct that identifies a variety of prevalent conditions associated with the use of medical adhesive device such as tapes and PICC dressings. These cases, in particular Cases 1 and 2, illustrate that the MARSI construct provides a framework for assessing and managing medical skin injuries with the possibility of preserving the PICC and the ongoing therapy these patients were receiving.</p>","PeriodicalId":49950,"journal":{"name":"Journal of Wound Ostomy and Continence Nursing","volume":"51 5S Suppl 5","pages":"S18-S23"},"PeriodicalIF":1.7000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Wound Ostomy and Continence Nursing","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/WON.0000000000001117","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/20 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"NURSING","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Medical adhesive-related skin injuries (MARSIs) are prevalent adverse effects associated with use of medical devices and increasingly recognized as potentially avoidable. Despite advances in preventive measures, MARSI events still occur, and individualized care must be designed to meet patient needs.
Cases: This article describes three cases where skin injuries occurred because of application, removal, and ongoing use of a medical adhesive device; all three cases occurred underneath dressings used to secure and protect the skin adjacent to a peripherally inserted central catheter (PICC). The first case describes evaluation and management of a skin tear in an elderly female with multiple comorbid conditions, and Case 2 describes assessment and care of contact irritant dermatitis occurring under a PICC dressing. In both cases, specialist nurses with knowledge of MARSI assessed and managed the skin underneath the medical adhesive device in a manner that allowed maintenance of the PICC and continuation of therapy. In contrast, Case 3 describes a female with irritant contact dermatitis underneath a PICC dressing that was responding to care by the nurse specialists of a vascular access team. In this case, the patient presented to their facility's emergency department with severe itching. The vascular access team initially was not consulted, and the PICC line was removed, although inspection revealed dry skin without signs of infection.
Conclusions: Medical adhesive-related skin injury is a clinically relevant and useful construct that identifies a variety of prevalent conditions associated with the use of medical adhesive device such as tapes and PICC dressings. These cases, in particular Cases 1 and 2, illustrate that the MARSI construct provides a framework for assessing and managing medical skin injuries with the possibility of preserving the PICC and the ongoing therapy these patients were receiving.
期刊介绍:
The Journal of Wound, Ostomy and Continence Nursing (JWOCN), the official journal of the Wound, Ostomy and Continence Nurses Society™ (WOCN®), is the premier publication for wound, ostomy and continence practice and research. The Journal’s mission is to publish current best evidence and original research to guide the delivery of expert health care.