{"title":"A compact motorized end-effector for ankle rehabilitation training.","authors":"Renxiang Wu, Mingyang Luo, Jiaming Fan, Jingting Ma, Naiwen Zhang, Jianjun Li, Qiuyuan Li, Fei Gao, Guo Dan","doi":"10.3389/frobt.2024.1453097","DOIUrl":null,"url":null,"abstract":"<p><p>This paper introduces a compact end-effector ankle rehabilitation robot (CEARR) system for addressing ankle range of motion (ROM) rehabilitation. The CEARR features a bilaterally symmetrical rehabilitation structure, with each side possessing three degrees of freedom (DOF) driven by three independently designed actuators. The working intervals of each actuator are separated by a series connection, ensuring they operate without interference to accommodate the dorsiflexion/plantarflexion (DO/PL), inversion/eversion (IN/EV), and adduction/abduction (AD/AB) DOF requirements for comprehensive ankle rehabilitation. In addition, we integrated an actuator and foldable brackets to accommodate patients in varied postures. We decoded the motor intention based on the surface electromyography (sEMG) and torque signals generated by the subjects' ankle joints in voluntary rehabilitation. Besides, we designed a real-time voluntary-triggered control (VTC) strategy to enhance the rehabilitation effect, in which the root mean square (RMS) of sEMG was utilized to trigger and adjust the CEARR rehabilitation velocity support. We verified the consistency of voluntary movement with CEARR rehabilitation support output for four healthy subjects on a nonlinear sEMG signal with an <math> <mrow><msup><mi>R</mi> <mn>2</mn></msup> </mrow> </math> metric of approximately 0.67. We tested the consistency of triggering velocity trends with a linear torque signal for one healthy individual with an <math> <mrow><msup><mi>R</mi> <mn>2</mn></msup> </mrow> </math> metric of approximately 0.99.</p>","PeriodicalId":47597,"journal":{"name":"Frontiers in Robotics and AI","volume":null,"pages":null},"PeriodicalIF":2.9000,"publicationDate":"2024-08-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11387888/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in Robotics and AI","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3389/frobt.2024.1453097","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"ROBOTICS","Score":null,"Total":0}
引用次数: 0

Abstract

This paper introduces a compact end-effector ankle rehabilitation robot (CEARR) system for addressing ankle range of motion (ROM) rehabilitation. The CEARR features a bilaterally symmetrical rehabilitation structure, with each side possessing three degrees of freedom (DOF) driven by three independently designed actuators. The working intervals of each actuator are separated by a series connection, ensuring they operate without interference to accommodate the dorsiflexion/plantarflexion (DO/PL), inversion/eversion (IN/EV), and adduction/abduction (AD/AB) DOF requirements for comprehensive ankle rehabilitation. In addition, we integrated an actuator and foldable brackets to accommodate patients in varied postures. We decoded the motor intention based on the surface electromyography (sEMG) and torque signals generated by the subjects' ankle joints in voluntary rehabilitation. Besides, we designed a real-time voluntary-triggered control (VTC) strategy to enhance the rehabilitation effect, in which the root mean square (RMS) of sEMG was utilized to trigger and adjust the CEARR rehabilitation velocity support. We verified the consistency of voluntary movement with CEARR rehabilitation support output for four healthy subjects on a nonlinear sEMG signal with an R 2 metric of approximately 0.67. We tested the consistency of triggering velocity trends with a linear torque signal for one healthy individual with an R 2 metric of approximately 0.99.

用于踝关节康复训练的小型电动末端执行器
本文介绍了一种用于踝关节活动范围(ROM)康复的紧凑型末端执行器踝关节康复机器人(CEARR)系统。CEARR 采用双侧对称的康复结构,每侧有三个自由度 (DOF),由三个独立设计的致动器驱动。每个致动器的工作区间通过串联连接分开,确保它们在工作时互不干扰,以满足踝关节综合康复对背屈/跖屈(DO/PL)、内翻/外翻(IN/EV)和内收/外展(AD/AB)DOF 的要求。此外,我们还集成了致动器和可折叠支架,以适应患者的不同姿势。我们根据受试者踝关节在自主康复过程中产生的表面肌电图(sEMG)和扭矩信号,对运动意向进行了解码。此外,我们还设计了一种实时自愿触发控制(VTC)策略,利用肌电图的均方根(RMS)来触发和调整CEARR康复速度支持,以提高康复效果。我们在 R 2 指标约为 0.67 的非线性 sEMG 信号上验证了四名健康受试者的自主运动与 CEARR 康复支持输出的一致性。我们测试了一名健康人使用线性扭矩信号触发速度趋势的一致性,R 2 指标约为 0.99。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.50
自引率
5.90%
发文量
355
审稿时长
14 weeks
期刊介绍: Frontiers in Robotics and AI publishes rigorously peer-reviewed research covering all theory and applications of robotics, technology, and artificial intelligence, from biomedical to space robotics.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信