Collaborative Study for the Calibration of the Ph.Eur. Prekallikrein Activator in Albumin Biological Reference Preparation batches 8, 9 and 10.

Q4 Medicine
Pharmeuropa bio & scientific notes Pub Date : 2024-01-01
C Kefeder, S Eichmeir, D Le Tallec, S Jouette
{"title":"Collaborative Study for the Calibration of the Ph.Eur. Prekallikrein Activator in Albumin Biological Reference Preparation batches 8, 9 and 10.","authors":"C Kefeder, S Eichmeir, D Le Tallec, S Jouette","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>An international collaborative study was organised by the European Directorate for the Quality of Medicines & HealthCare (EDQM, Council of Europe) to calibrate replacement batches for the current European Pharmacopoeia (Ph. Eur.) Prekallikrein Activator (PKA) in albumin Biological Reference Preparation (BRP) whose stocks were dwindling. The study was run in the framework of the Biological Standardisation Programme (BSP) of the Council of Europe and the European Union (EU) Commission. Twenty-four laboratories from official medicines control authorities and manufacturers in Europe and outside Europe took part in the study. Three candidate replacement batches were produced with albumin solutions artificially spiked with a PKA concentrate to increase their PKA level. Participants were requested to evaluate the candidate batches against the 3rd World Health Organization (WHO) International Standard (IS) for Prekallikrein activator in albumin (16/364) using their routine assay method. The Ph. Eur. PKA in albumin BRP batch 7 (BRP7) was also included in the test panel to ensure the continuity of the consecutive BRP batches. The 3 candidate replacement batches were considered suitable for their intended use as BRPs. The study confirmed the stability of the PKA content of the current BRP7. Thermal stress study on the candidate batches confirmed the stability of their PKA activity. In December 2023, the Ph. Eur. Commission officially adopted the 3 candidate batches as Ph. Eur. PKA in albumin BRP batches 8, 9 and 10 with assigned potencies of 37 IU/vial, 33 IU/vial and 34 IU/vial, respectively. The activity of the 3 new batches of Ph. Eur. PKA in albumin BRP will be regularly monitored.</p>","PeriodicalId":39192,"journal":{"name":"Pharmeuropa bio & scientific notes","volume":"2024 ","pages":"193-220"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pharmeuropa bio & scientific notes","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

An international collaborative study was organised by the European Directorate for the Quality of Medicines & HealthCare (EDQM, Council of Europe) to calibrate replacement batches for the current European Pharmacopoeia (Ph. Eur.) Prekallikrein Activator (PKA) in albumin Biological Reference Preparation (BRP) whose stocks were dwindling. The study was run in the framework of the Biological Standardisation Programme (BSP) of the Council of Europe and the European Union (EU) Commission. Twenty-four laboratories from official medicines control authorities and manufacturers in Europe and outside Europe took part in the study. Three candidate replacement batches were produced with albumin solutions artificially spiked with a PKA concentrate to increase their PKA level. Participants were requested to evaluate the candidate batches against the 3rd World Health Organization (WHO) International Standard (IS) for Prekallikrein activator in albumin (16/364) using their routine assay method. The Ph. Eur. PKA in albumin BRP batch 7 (BRP7) was also included in the test panel to ensure the continuity of the consecutive BRP batches. The 3 candidate replacement batches were considered suitable for their intended use as BRPs. The study confirmed the stability of the PKA content of the current BRP7. Thermal stress study on the candidate batches confirmed the stability of their PKA activity. In December 2023, the Ph. Eur. Commission officially adopted the 3 candidate batches as Ph. Eur. PKA in albumin BRP batches 8, 9 and 10 with assigned potencies of 37 IU/vial, 33 IU/vial and 34 IU/vial, respectively. The activity of the 3 new batches of Ph. Eur. PKA in albumin BRP will be regularly monitored.

校准 Ph.Eur.白蛋白生物参考制剂第 8、9 和 10 批次中的前胰激肽原激活剂。
欧洲药品和保健质量管理局(EDQM,欧洲委员会)组织了一项国际合作研究,以校准库存日益减少的现行欧洲药典(Ph. Eur.)白蛋白生物参考制剂(BRP)中的预激肽原激活剂(PKA)的替代批次。这项研究是在欧洲委员会和欧盟(EU)委员会生物标准化计划(BSP)框架内进行的。来自欧洲和欧洲以外的官方药品控制机构和制造商的 24 家实验室参加了这项研究。三个候选替代批次的白蛋白溶液被人为添加了 PKA 浓缩物,以提高其 PKA 含量。要求参与者使用其常规检测方法,根据世界卫生组织(WHO)关于白蛋白中预胰激肽原激活剂的第 3 版国际标准(IS)(16/364)对候选批次进行评估。欧洲药典白蛋白中的 PKA 第 7 批 BRP(BRP7)也被纳入了检测小组,以确保连续 BRP 批次的连续性。3 个候选替代批次被认为适合用作 BRP。研究证实了当前 BRP7 中 PKA 含量的稳定性。对候选批次进行的热应力研究证实了其 PKA 活性的稳定性。2023 年 12 月,欧洲药典委员会正式通过了这 3 个候选批次。2023 年 12 月,欧洲药典委员会正式通过这 3 个候选批次为欧洲药典(Ph. Eur.PKA in albumin BRP 的第 8、9 和 10 批产品,效价分别为 37 IU/vial、33 IU/vial 和 34 IU/vial。这 3 批新的 Ph. Eur.将定期监测白蛋白 BRP 中 PKA 的活性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Pharmeuropa bio & scientific notes
Pharmeuropa bio & scientific notes Medicine-Medicine (all)
CiteScore
0.70
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信