Long-Term Results After Hallux Valgus Correction with Distal Metatarsal Reversed-L (ReveL) Osteotomy: Factors That Influence Recurrence and the Clinical Outcome.
Lizzy Weigelt, Noah Davolio, Carlos Torrez, Florian Haug, Nathalie Kühne, Stephan H Wirth
{"title":"Long-Term Results After Hallux Valgus Correction with Distal Metatarsal Reversed-L (ReveL) Osteotomy: Factors That Influence Recurrence and the Clinical Outcome.","authors":"Lizzy Weigelt, Noah Davolio, Carlos Torrez, Florian Haug, Nathalie Kühne, Stephan H Wirth","doi":"10.2106/JBJS.OA.24.00042","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>This study aimed to evaluate the long-term results of hallux valgus correction with a distal metatarsal reversed-L (ReveL) osteotomy.</p><p><strong>Methods: </strong>Eighty-eight patients (131 feet) were evaluated after a mean follow-up of 14.2 years (range, 10 to 18 years). Weight-bearing foot radiographs were analyzed preoperatively, at 6 weeks postoperatively, and at the final follow-up for the following parameters: hallux valgus angle (HVA), intermetatarsal angle (IMA), first metatarsophalangeal joint (MTPJ) congruence angle, sesamoid position, presence of the round sign, and first MTPJ arthritis. The visual analog scale (VAS) and the Foot and Ankle Outcome Score (FAOS) assessed postoperative pain and function. Univariate and multivariable logistic regression analyses identified risk factors for hallux valgus recurrence and an inferior clinical outcome.</p><p><strong>Results: </strong>All radiographic parameters significantly improved at the 6-week follow-up and the final follow-up (p < 0.001). The recurrence rate (HVA >20°) was 14%. A preoperative HVA of >28° (odds ratio [OR], 9.1; p = 0.02) and a 6-week postoperative HVA of >15° (OR, 4.6; p = 0.03) were independent risk factors for recurrence. At the final follow-up, all FAOS subscales resembled high postoperative function (median, 100 points [range of the interquartile range (IQR), 81 to 100 points]). A preoperative body mass index of >30 kg/m<sup>2</sup> was associated with lower FAOS quality of life (QOL) (p = 0.04), and postoperative hallux varus was associated with lower FAOS activities of daily living (p = 0.048). Patients with first MTPJ arthritis of grade 2 or higher at the final follow-up had significantly lower FAOS subscales (p < 0.01) except for QOL. Hallux valgus recurrence did not influence the long-term outcome. A symptomatic implant was the main cause of revision (15%). In 94% of cases, the patients were satisfied with the hallux appearance and, in 92% of cases, the patients were satisfied with postoperative pain reduction.</p><p><strong>Conclusions: </strong>Hallux valgus correction with a ReveL osteotomy led to high long-term satisfaction rates. A preoperative HVA of >28° and a 6-week postoperative HVA of >15° increased the risk of hallux valgus recurrence. First MTPJ arthritis was the leading cause of inferior clinical results, whereas radiographic hallux valgus recurrence had no impact on the clinical results. First MTPJ arthritis at the final follow-up was associated with an inferior clinical outcome, whereas radiographic hallux valgus recurrence had no impact on the long-term clinical results.</p><p><strong>Level of evidence: </strong>Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.</p>","PeriodicalId":36492,"journal":{"name":"JBJS Open Access","volume":"9 3","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2024-09-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11392477/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JBJS Open Access","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2106/JBJS.OA.24.00042","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: This study aimed to evaluate the long-term results of hallux valgus correction with a distal metatarsal reversed-L (ReveL) osteotomy.
Methods: Eighty-eight patients (131 feet) were evaluated after a mean follow-up of 14.2 years (range, 10 to 18 years). Weight-bearing foot radiographs were analyzed preoperatively, at 6 weeks postoperatively, and at the final follow-up for the following parameters: hallux valgus angle (HVA), intermetatarsal angle (IMA), first metatarsophalangeal joint (MTPJ) congruence angle, sesamoid position, presence of the round sign, and first MTPJ arthritis. The visual analog scale (VAS) and the Foot and Ankle Outcome Score (FAOS) assessed postoperative pain and function. Univariate and multivariable logistic regression analyses identified risk factors for hallux valgus recurrence and an inferior clinical outcome.
Results: All radiographic parameters significantly improved at the 6-week follow-up and the final follow-up (p < 0.001). The recurrence rate (HVA >20°) was 14%. A preoperative HVA of >28° (odds ratio [OR], 9.1; p = 0.02) and a 6-week postoperative HVA of >15° (OR, 4.6; p = 0.03) were independent risk factors for recurrence. At the final follow-up, all FAOS subscales resembled high postoperative function (median, 100 points [range of the interquartile range (IQR), 81 to 100 points]). A preoperative body mass index of >30 kg/m2 was associated with lower FAOS quality of life (QOL) (p = 0.04), and postoperative hallux varus was associated with lower FAOS activities of daily living (p = 0.048). Patients with first MTPJ arthritis of grade 2 or higher at the final follow-up had significantly lower FAOS subscales (p < 0.01) except for QOL. Hallux valgus recurrence did not influence the long-term outcome. A symptomatic implant was the main cause of revision (15%). In 94% of cases, the patients were satisfied with the hallux appearance and, in 92% of cases, the patients were satisfied with postoperative pain reduction.
Conclusions: Hallux valgus correction with a ReveL osteotomy led to high long-term satisfaction rates. A preoperative HVA of >28° and a 6-week postoperative HVA of >15° increased the risk of hallux valgus recurrence. First MTPJ arthritis was the leading cause of inferior clinical results, whereas radiographic hallux valgus recurrence had no impact on the clinical results. First MTPJ arthritis at the final follow-up was associated with an inferior clinical outcome, whereas radiographic hallux valgus recurrence had no impact on the long-term clinical results.
Level of evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.