Zahra Ahmadi Ganjeh, Brian Zapien-Campos, Erik Traneus, Stefan Both, Peter Dendooven
{"title":"RayStation/GATE Monte Carlo simulation framework for verification of proton therapy based on the<sup>12</sup>N imaging.","authors":"Zahra Ahmadi Ganjeh, Brian Zapien-Campos, Erik Traneus, Stefan Both, Peter Dendooven","doi":"10.1088/1361-6560/ad7d5c","DOIUrl":null,"url":null,"abstract":"<p><p><i>Objective</i>.<sup>12</sup>N, having a half-life of 11 ms, is a highly effective positron emitter that can potentially provide near real-time feedback in proton therapy. There is currently no framework for comparing and validating positron emission imaging of<sup>12</sup>N. This work describes the development and validation of a Monte Carlo (MC) framework to calculate the images of<sup>12</sup>N, as well as long-lived isotopes, originating from activation by protons.<i>Approach</i>. The available dual-panel Biograph mCT PET scanner was modeled in GATE and validated by comparing the simulated sensitivity map with the measured one. The distributions of<sup>12</sup>N and long-lived isotopes were calculated by RayStation and used as the input of GATE simulations. The RayStation/GATE combination was verified using proton beam irradiations of homogeneous phantoms. A 120 MeV pulsed pencil beam with 10<sup>8</sup>protons per pulse was used. Two-dimensional images were created from the GATE output and compared with the images based on the measurements and the 1D longitudinal projection of the full 2D image was used to calculate the<sup>12</sup>N activity range.<i>Main results</i>. The simulated sensitivity in the center of the FoV (5.44%) agrees well with the measured one (5.41%). The simulated and measured 2D sensitivity maps agree in good detail. The relative difference between the measured and simulated positron activity range for both<sup>12</sup>N and long-lived isotopes is less than 1%. The broadening of the<sup>12</sup>N images relative to those of the longer-lived isotopes can be understood in terms of the large positron range of<sup>12</sup>N.<i>Significance</i>. We developed and validated a MC framework based on RayStation/GATE to support the in-beam PET method for quality assurance of proton therapy. The inclusion of the very short-lived isotope<sup>12</sup>N makes the framework useful for developing near real-time verification. This represents a significant step towards translating<sup>12</sup>N real-time in vivo verification to the clinic.</p>","PeriodicalId":20185,"journal":{"name":"Physics in medicine and biology","volume":null,"pages":null},"PeriodicalIF":3.3000,"publicationDate":"2024-09-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physics in medicine and biology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1088/1361-6560/ad7d5c","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Objective.12N, having a half-life of 11 ms, is a highly effective positron emitter that can potentially provide near real-time feedback in proton therapy. There is currently no framework for comparing and validating positron emission imaging of12N. This work describes the development and validation of a Monte Carlo (MC) framework to calculate the images of12N, as well as long-lived isotopes, originating from activation by protons.Approach. The available dual-panel Biograph mCT PET scanner was modeled in GATE and validated by comparing the simulated sensitivity map with the measured one. The distributions of12N and long-lived isotopes were calculated by RayStation and used as the input of GATE simulations. The RayStation/GATE combination was verified using proton beam irradiations of homogeneous phantoms. A 120 MeV pulsed pencil beam with 108protons per pulse was used. Two-dimensional images were created from the GATE output and compared with the images based on the measurements and the 1D longitudinal projection of the full 2D image was used to calculate the12N activity range.Main results. The simulated sensitivity in the center of the FoV (5.44%) agrees well with the measured one (5.41%). The simulated and measured 2D sensitivity maps agree in good detail. The relative difference between the measured and simulated positron activity range for both12N and long-lived isotopes is less than 1%. The broadening of the12N images relative to those of the longer-lived isotopes can be understood in terms of the large positron range of12N.Significance. We developed and validated a MC framework based on RayStation/GATE to support the in-beam PET method for quality assurance of proton therapy. The inclusion of the very short-lived isotope12N makes the framework useful for developing near real-time verification. This represents a significant step towards translating12N real-time in vivo verification to the clinic.
期刊介绍:
The development and application of theoretical, computational and experimental physics to medicine, physiology and biology. Topics covered are: therapy physics (including ionizing and non-ionizing radiation); biomedical imaging (e.g. x-ray, magnetic resonance, ultrasound, optical and nuclear imaging); image-guided interventions; image reconstruction and analysis (including kinetic modelling); artificial intelligence in biomedical physics and analysis; nanoparticles in imaging and therapy; radiobiology; radiation protection and patient dose monitoring; radiation dosimetry