Influence of Visual Field on Visual Acuity and Contrast Sensitivity in Open-Angle Glaucoma Eyes with Monofocal and Extended Depth-of-Focus Intraocular Lenses.

IF 2.6 3区 医学 Q2 OPHTHALMOLOGY
Hiroko Bissen-Miyajima, Yuka Ota, Keiichiro Minami, Yoko Taira, Ryo Takemura
{"title":"Influence of Visual Field on Visual Acuity and Contrast Sensitivity in Open-Angle Glaucoma Eyes with Monofocal and Extended Depth-of-Focus Intraocular Lenses.","authors":"Hiroko Bissen-Miyajima, Yuka Ota, Keiichiro Minami, Yoko Taira, Ryo Takemura","doi":"10.1007/s40123-024-01035-5","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The aim of this prospective and comparative study was to investigate the association of perimetry parameters on visual acuity and contrast sensitivity in primary open-angle glaucoma (POAG) eyes with diffractive extended depth-of-focus (EDoF) and monofocal intraocular lenses (IOLs).</p><p><strong>Methods: </strong>In cataract eyes with medicinally controlled POAG with no defects in the central visual field and mean deviation (MD) values of - 10 dB or better, EDoF and monofocal IOLs with the same platform except for echelette optics for EDoF were implanted in 22 and 24 eyes, respectively. Corrected distance visual acuity (CDVA), contrast sensitivity at 3 to 18 cycles per degree (cpd), and automated perimetry using 30-2 and 10-2 Swedish Interactive Threshold Algorithm programs were examined 3 months postoperatively. The influences of perimetry parameters including MD, foveal sensitivity (FS), and the means of the central four points (central MD and central FS) on CDVA and contrast sensitivity were evaluated using linear and multiple regression analyses.</p><p><strong>Results: </strong>In POAG eyes with EDoF IOLs, contrast sensitivities at 12 and 18 cpd were associated with 30-2 and 10-2 perimetry parameters. In POAG eyes with monofocal IOLs, associations of 30-2 parameters were found in CDVA and 3-cpd contrast sensitivity.</p><p><strong>Conclusions: </strong>The visual function of POAG eyes with EDoF IOLs was associated with perimetry parameters in high spatial frequency contrast sensitivity, which was different from that of POAG eyes with monofocal IOL.</p><p><strong>Trial registration: </strong>Japan Registry for Clinical Research: jRCTs032200218.</p>","PeriodicalId":19623,"journal":{"name":"Ophthalmology and Therapy","volume":null,"pages":null},"PeriodicalIF":2.6000,"publicationDate":"2024-09-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmology and Therapy","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s40123-024-01035-5","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: The aim of this prospective and comparative study was to investigate the association of perimetry parameters on visual acuity and contrast sensitivity in primary open-angle glaucoma (POAG) eyes with diffractive extended depth-of-focus (EDoF) and monofocal intraocular lenses (IOLs).

Methods: In cataract eyes with medicinally controlled POAG with no defects in the central visual field and mean deviation (MD) values of - 10 dB or better, EDoF and monofocal IOLs with the same platform except for echelette optics for EDoF were implanted in 22 and 24 eyes, respectively. Corrected distance visual acuity (CDVA), contrast sensitivity at 3 to 18 cycles per degree (cpd), and automated perimetry using 30-2 and 10-2 Swedish Interactive Threshold Algorithm programs were examined 3 months postoperatively. The influences of perimetry parameters including MD, foveal sensitivity (FS), and the means of the central four points (central MD and central FS) on CDVA and contrast sensitivity were evaluated using linear and multiple regression analyses.

Results: In POAG eyes with EDoF IOLs, contrast sensitivities at 12 and 18 cpd were associated with 30-2 and 10-2 perimetry parameters. In POAG eyes with monofocal IOLs, associations of 30-2 parameters were found in CDVA and 3-cpd contrast sensitivity.

Conclusions: The visual function of POAG eyes with EDoF IOLs was associated with perimetry parameters in high spatial frequency contrast sensitivity, which was different from that of POAG eyes with monofocal IOL.

Trial registration: Japan Registry for Clinical Research: jRCTs032200218.

视野对配戴单焦和延展焦距眼内透镜的开角型青光眼患者视力和对比敏感度的影响
前言:这项前瞻性对比研究旨在探讨原发性开角型青光眼(POAG)患者配戴衍射型延焦深度(EDoF)和单焦点人工晶体(IOLs)后,周边视力参数与视力和对比敏感度的关系:在 22 只和 24 只药物控制的白内障 POAG 眼中,分别植入了中心视野无缺陷且平均偏差 (MD) 值为 - 10 dB 或更高的 EDoF 和单焦点 IOL,EDoF 采用了相同的平台,但 EDoF 采用了 echelette 光学镜片。术后 3 个月,对矫正远视力 (CDVA)、每度 3 到 18 个周期 (cpd) 的对比敏感度以及使用 30-2 和 10-2 瑞典交互式阈值算法程序进行的自动验光进行了检查。使用线性和多元回归分析评估了包括MD、眼窝灵敏度(FS)和中心四点平均值(中心MD和中心FS)在内的视力参数对CDVA和对比灵敏度的影响:结果:在使用 EDoF IOL 的 POAG 眼睛中,12 和 18 cpd 的对比敏感度与 30-2 和 10-2 的验光参数相关。在配戴单焦点人工晶体的 POAG 眼睛中,30-2 参数与 CDVA 和 3 cpd 对比敏感度相关:结论:配戴 EDoF IOL 的 POAG 眼睛的视觉功能与高空间频率对比敏感度的测光参数有关,这与配戴单焦点 IOL 的 POAG 眼睛的视觉功能不同:日本临床研究注册中心:jRCTs032200218。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Ophthalmology and Therapy
Ophthalmology and Therapy OPHTHALMOLOGY-
CiteScore
4.20
自引率
3.00%
发文量
157
审稿时长
6 weeks
期刊介绍: Aims and Scope Ophthalmology and Therapy is an international, open access, peer-reviewed (single-blind), and rapid publication journal. The scope of the journal is broad and will consider all scientifically sound research from preclinical, clinical (all phases), observational, real-world, and health outcomes research around the use of ophthalmological therapies, devices, and surgical techniques. The journal is of interest to a broad audience of pharmaceutical and healthcare professionals and publishes original research, reviews, case reports/series, trial protocols and short communications such as commentaries and editorials. Ophthalmology and Therapy will consider all scientifically sound research be it positive, confirmatory or negative data. Submissions are welcomed whether they relate to an international and/or a country-specific audience, something that is crucially important when researchers are trying to target more specific patient populations. This inclusive approach allows the journal to assist in the dissemination of quality research, which may be considered of insufficient interest by other journals. Rapid Publication The journal’s publication timelines aim for a rapid peer review of 2 weeks. If an article is accepted it will be published 3–4 weeks from acceptance. The rapid timelines are achieved through the combination of a dedicated in-house editorial team, who manage article workflow, and an extensive Editorial and Advisory Board who assist with peer review. This allows the journal to support the rapid dissemination of research, whilst still providing robust peer review. Combined with the journal’s open access model this allows for the rapid, efficient communication of the latest research and reviews, fostering the advancement of ophthalmic therapies. Open Access All articles published by Ophthalmology and Therapy are open access. Personal Service The journal’s dedicated in-house editorial team offer a personal “concierge service” meaning authors will always have an editorial contact able to update them on the status of their manuscript. The editorial team check all manuscripts to ensure that articles conform to the most recent COPE, GPP and ICMJE publishing guidelines. This supports the publication of ethically sound and transparent research. Digital Features and Plain Language Summaries Ophthalmology and Therapy offers a range of additional features designed to increase the visibility, readership and educational value of the journal’s content. Each article is accompanied by key summary points, giving a time-efficient overview of the content to a wide readership. Articles may be accompanied by plain language summaries to assist readers who have some knowledge of, but not in-depth expertise in, the area to understand the scientific content and overall implications of the article. The journal also provides the option to include various types of digital features including animated abstracts, video abstracts, slide decks, audio slides, instructional videos, infographics, podcasts and animations. All additional features are peer reviewed to the same high standard as the article itself. If you consider that your paper would benefit from the inclusion of a digital feature, please let us know. Our editorial team are able to create high-quality slide decks and infographics in-house, and video abstracts through our partner Research Square, and would be happy to assist in any way we can. For further information about digital features, please contact the journal editor (see ‘Contact the Journal’ for email address), and see the ‘Guidelines for digital features and plain language summaries’ document under ‘Submission guidelines’. For examples of digital features please visit our showcase page https://springerhealthcare.com/expertise/publishing-digital-features/ Publication Fees Upon acceptance of an article, authors will be required to pay the mandatory Rapid Service Fee of €5250/$6000/£4300. The journal will consider fee discounts and waivers for developing countries and this is decided on a case by case basis. Peer Review Process Upon submission, manuscripts are assessed by the editorial team to ensure they fit within the aims and scope of the journal and are also checked for plagiarism. All suitable submissions are then subject to a comprehensive single-blind peer review. Reviewers are selected based on their relevant expertise and publication history in the subject area. The journal has an extensive pool of editorial and advisory board members who have been selected to assist with peer review based on the afore-mentioned criteria. At least two extensive reviews are required to make the editorial decision, with the exception of some article types such as Commentaries, Editorials, and Letters which are generally reviewed by one member of the Editorial Board. Where reviewer recommendations are conflicted, the editorial board will be contacted for further advice and a presiding decision. Manuscripts are then either accepted, rejected or authors are required to make major or minor revisions (both reviewer comments and editorial comments may need to be addressed). Once a revised manuscript is re-submitted, it is assessed along with the responses to reviewer comments and if it has been adequately revised it will be accepted for publication. Accepted manuscripts are then copyedited and typeset by the production team before online publication. Appeals against decisions following peer review are considered on a case-by-case basis and should be sent to the journal editor. Preprints We encourage posting of preprints of primary research manuscripts on preprint servers, authors’ or institutional websites, and open communications between researchers whether on community preprint servers or preprint commenting platforms. Posting of preprints is not considered prior publication and will not jeopardize consideration in our journals. Authors should disclose details of preprint posting during the submission process or at any other point during consideration in one of our journals. Once the manuscript is published, it is the author’s responsibility to ensure that the preprint record is updated with a publication reference, including the DOI and a URL link to the published version of the article on the journal website. Please follow the link for further information on preprint sharing: https://www.springer.com/gp/authors-editors/journal-author/journal-author-helpdesk/submission/1302#c16721550 Copyright Ophthalmology and Therapy''s content is published open access under the Creative Commons Attribution-Noncommercial License, which allows users to read, copy, distribute, and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited. The author assigns the exclusive right to any commercial use of the article to Springer. For more information about the Creative Commons Attribution-Noncommercial License, click here: http://creativecommons.org/licenses/by-nc/4.0. Contact For more information about the journal, including pre-submission enquiries, please contact christopher.vautrinot@springer.com.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信