Quantitation of Host Cell Proteins by Capillary LC/IMS/MS/MS in Combination with Rapid Digestion on Immobilized Trypsin Column Under Native Conditions.

Q3 Physics and Astronomy
Mass spectrometry Pub Date : 2024-01-01 Epub Date: 2024-09-14 DOI:10.5702/massspectrometry.A0152
Ryota Tomioka, Kosuke Ogata, Yasushi Ishihama
{"title":"Quantitation of Host Cell Proteins by Capillary LC/IMS/MS/MS in Combination with Rapid Digestion on Immobilized Trypsin Column Under Native Conditions.","authors":"Ryota Tomioka, Kosuke Ogata, Yasushi Ishihama","doi":"10.5702/massspectrometry.A0152","DOIUrl":null,"url":null,"abstract":"<p><p>Host cell protein (HCP) impurities are considered a critical quality attribute of biopharmaceuticals because of their potential to compromise safety and efficacy, and LC/MS-based analytical methods have been developed to identify and quantify individual proteins instead of employing enzyme-linked immunosorbent assay to assess total HCP levels. Native digestion enables highly sensitive detection of HCPs but requires overnight incubation to generate peptides, limiting the throughput of sample preparation. In this study, we developed an approach employing native digestion on a trypsin-immobilized column to improve the sensitivity and throughput. We examined suitable databases for the identification of HCPs derived from Chinese hamster ovary (CHO) cells and selected RefSeq's Chinese Hamster as the optimal database. Then, we investigated methods to identify HCPs with greater efficiency than that of denatured in-solution digestion. Native in-column digestion not only reduced the digestion time from overnight to 10 min but also increased the number of quantified HCPs from 154 to 226. In addition to this rapid digestion methodology, we developed high-throughput LC/MS/MS with a monolithic silica column and parallel reaction monitoring-parallel accumulation-serial fragmentation. The optimized system was validated with synthetic peptides derived from high-risk HCPs, confirming excellent linearity, precision, accuracy, and low limit of detection (LOD) and limit of quantification (LOQ) (1-3 ppm). The optimized digestion and analysis method enabled high-throughput quantification of HCPs, and is expected to be useful for quality control and characterization of HCPs in antibody drugs.</p>","PeriodicalId":18243,"journal":{"name":"Mass spectrometry","volume":"13 1","pages":"A0152"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11409222/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Mass spectrometry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5702/massspectrometry.A0152","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/14 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"Physics and Astronomy","Score":null,"Total":0}
引用次数: 0

Abstract

Host cell protein (HCP) impurities are considered a critical quality attribute of biopharmaceuticals because of their potential to compromise safety and efficacy, and LC/MS-based analytical methods have been developed to identify and quantify individual proteins instead of employing enzyme-linked immunosorbent assay to assess total HCP levels. Native digestion enables highly sensitive detection of HCPs but requires overnight incubation to generate peptides, limiting the throughput of sample preparation. In this study, we developed an approach employing native digestion on a trypsin-immobilized column to improve the sensitivity and throughput. We examined suitable databases for the identification of HCPs derived from Chinese hamster ovary (CHO) cells and selected RefSeq's Chinese Hamster as the optimal database. Then, we investigated methods to identify HCPs with greater efficiency than that of denatured in-solution digestion. Native in-column digestion not only reduced the digestion time from overnight to 10 min but also increased the number of quantified HCPs from 154 to 226. In addition to this rapid digestion methodology, we developed high-throughput LC/MS/MS with a monolithic silica column and parallel reaction monitoring-parallel accumulation-serial fragmentation. The optimized system was validated with synthetic peptides derived from high-risk HCPs, confirming excellent linearity, precision, accuracy, and low limit of detection (LOD) and limit of quantification (LOQ) (1-3 ppm). The optimized digestion and analysis method enabled high-throughput quantification of HCPs, and is expected to be useful for quality control and characterization of HCPs in antibody drugs.

在原生条件下通过毛细管液相色谱/质谱/质谱联用固定化胰蛋白酶柱快速消化法定量宿主细胞蛋白质
宿主细胞蛋白(HCP)杂质被认为是生物制药的一个关键质量属性,因为它们有可能影响生物制药的安全性和有效性,因此人们开发了基于 LC/MS 的分析方法来鉴定和量化单个蛋白质,而不是采用酶联免疫吸附测定法来评估 HCP 的总含量。原位消化可实现高灵敏度的 HCP 检测,但需要过夜孵育才能生成肽,从而限制了样品制备的通量。在本研究中,我们开发了一种在胰蛋白酶固定化柱上进行原位消化的方法,以提高灵敏度和处理量。我们研究了用于鉴定中国仓鼠卵巢(CHO)细胞中 HCPs 的合适数据库,并选择 RefSeq 的中国仓鼠作为最佳数据库。然后,我们研究了比变性溶液消化效率更高的 HCPs 鉴定方法。柱内原生消解不仅将消解时间从过夜缩短到 10 分钟,还将定量的 HCPs 数量从 154 个增加到 226 个。除了这种快速消解方法外,我们还开发了高通量 LC/MS/MS,该系统采用整体硅胶柱和平行反应监测-平行累积-串联碎裂技术。我们用来自高风险 HCP 的合成肽对优化后的系统进行了验证,结果表明该系统线性度、精密度、准确度极佳,而且检出限 (LOD) 和定量限 (LOQ) 都很低(1-3 ppm)。优化的消化和分析方法实现了高通量 HCPs 定量,有望用于抗体药物中 HCPs 的质量控制和表征。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Mass spectrometry
Mass spectrometry Physics and Astronomy-Instrumentation
CiteScore
1.90
自引率
0.00%
发文量
3
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信