{"title":"Exposure to ionizing radiation of medical staff performing vascular and interventional radiology procedures.","authors":"Michał Biegała, Teresa Jakubowska, Joanna Domienik-Andrzejewska","doi":"10.13075/ijomeh.1896.02462","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Vascular and interventional radiology procedures are characterized by high exposure of personnel to ionizing radiation. This study assessed the exposure of medical personnel to ionizing radiation during vascular radiology and mechanical thrombectomy procedures.</p><p><strong>Material and methods: </strong>During vascular radiology procedures, the exposure of 4 groups of workers participating in the procedures was analyzed, i.e., the main operating physician, an assistant physician, a sterile nurse, and a nurse. Measurements of exposure to ionizing radiation were performed using thermoluminescent dosimetry.</p><p><strong>Results: </strong>The registered effective dose during 1 treatment in individual groups is, respectively: mean (M) ± standard deviation (SD) 75±15 μSv, 24±5 μSv, 13±3 μSv, and 8±2 μSv. During mechanical thrombectomy, the operating physician receives an effective dose of M±SD 9±2 μSv. The equivalent doses for the lenses for the operating physician and the doctor assisting during vascular radiology procedures are M±SD 1419±285 μSv and 987±198 μSv, respectively, and for the hands, including the left and right hands, M±SD 4605±930 μSv, 1420±284 μSv, 1898±380 μSv, 1371±274 μSv.</p><p><strong>Conclusions: </strong>If the principles of optimizing radiological protection are not applied during vascular radiology procedures, the permissible dose limits and operational limits equivalent to doses to lenses and hands may be exceeded. Exposure during vascular radiology procedures is comparable to exposure during nuclear medicine procedures in terms of the use of glucose labeled with radioactive fluorine. Int J Occup Med Environ Health. 2024;37(4):403-10.</p>","PeriodicalId":14173,"journal":{"name":"International journal of occupational medicine and environmental health","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-11-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of occupational medicine and environmental health","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.13075/ijomeh.1896.02462","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/9/11 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"PUBLIC, ENVIRONMENTAL & OCCUPATIONAL HEALTH","Score":null,"Total":0}
引用次数: 0
Abstract
Objectives: Vascular and interventional radiology procedures are characterized by high exposure of personnel to ionizing radiation. This study assessed the exposure of medical personnel to ionizing radiation during vascular radiology and mechanical thrombectomy procedures.
Material and methods: During vascular radiology procedures, the exposure of 4 groups of workers participating in the procedures was analyzed, i.e., the main operating physician, an assistant physician, a sterile nurse, and a nurse. Measurements of exposure to ionizing radiation were performed using thermoluminescent dosimetry.
Results: The registered effective dose during 1 treatment in individual groups is, respectively: mean (M) ± standard deviation (SD) 75±15 μSv, 24±5 μSv, 13±3 μSv, and 8±2 μSv. During mechanical thrombectomy, the operating physician receives an effective dose of M±SD 9±2 μSv. The equivalent doses for the lenses for the operating physician and the doctor assisting during vascular radiology procedures are M±SD 1419±285 μSv and 987±198 μSv, respectively, and for the hands, including the left and right hands, M±SD 4605±930 μSv, 1420±284 μSv, 1898±380 μSv, 1371±274 μSv.
Conclusions: If the principles of optimizing radiological protection are not applied during vascular radiology procedures, the permissible dose limits and operational limits equivalent to doses to lenses and hands may be exceeded. Exposure during vascular radiology procedures is comparable to exposure during nuclear medicine procedures in terms of the use of glucose labeled with radioactive fluorine. Int J Occup Med Environ Health. 2024;37(4):403-10.
期刊介绍:
The Journal is dedicated to present the contemporary research in occupational and environmental health from all over the world. It publishes works concerning: occupational and environmental: medicine, epidemiology, hygiene and toxicology; work physiology and ergonomics, musculoskeletal problems; psychosocial factors at work, work-related mental problems, aging, work ability and return to work; working hours, shift work; reproductive factors and endocrine disruptors; radiation, ionizing and non-ionizing health effects; agricultural hazards; work safety and injury and occupational health service; climate change and its effects on health; omics, genetics and epigenetics in occupational and environmental health; health effects of exposure to nanoparticles and nanotechnology products; human biomarkers in occupational and environmental health, intervention studies, clinical sciences’ achievements with potential to improve occupational and environmental health.