Is an all‐phase ITV (internal target volume) a gold standard in the target definition of hepatocellular carcinoma?

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS
Rishabh Kumar, Anil Gupta, Bhaskar Vishwanathan, Rose Kamal, Deepak Thaper
{"title":"Is an all‐phase ITV (internal target volume) a gold standard in the target definition of hepatocellular carcinoma?","authors":"Rishabh Kumar, Anil Gupta, Bhaskar Vishwanathan, Rose Kamal, Deepak Thaper","doi":"10.1002/acm2.14532","DOIUrl":null,"url":null,"abstract":"BackgroundStereotactic ablative body radiation (SABR) is a well‐recognized treatment option for hepatocellular carcinoma (HCC). Due to the inherent motion of liver tumors, effective motion management is crucial for successful SABR. In the motion‐encompassing motion management technique, all 10 respiratory phase image datasets are delineated and designated as the internal target volume (ITV). Some treatment centers use single or combination image sets to delineate the target volume. This study determines which specialty image set most closely matches an all‐phase ITV contour on a synchronized contrast‐enhanced 4DCT.Materials and methodsSynchronized 4DCT contrast and delayed scans were acquired for 10 patients in the study. The maximum intensity projection (MiP), average intensity projection (AvgIP), and minimum intensity projection (MinIP) images were generated. The ITV delineation was done in all 10 phases (ITV_all_phase). The ITV_2phase combines the peak inhale and exhale phase, ITV_2 M combines MiP and MinIP, and ITV_3 M combines MiP, MinIP, and AvgIP. All ITVs were compared to ITV_all_phase with Dice similarity index (DSI) and volumes.ResultsUsing ITV_all_phase as the reference, the DSI and the mean ITV volumes for the different ITVs were as follows: ITV_all_phase (1 and 116.69 cc), ITV_2phase (0.87 and 105.27 cc), MiP (0.76 and 98.24 cc), AvgIP (0.72 and 94.54 cc), ITV_MinIP (0.67 and 81.08 cc), ITV_2 M (0.84 and 106.26 cc), and ITV_3 M (0.86 and 112.51 cc).ConclusionThe study demonstrates that in the motion‐encompassing technique of motion management, the target volume generated by delineating all phases of 4DCT provides the most accurate representation for patients with HCC. Specialty image sets and their combinations, while sometimes close, tend to result in less accurate targeting. Hence, the all‐phase 4DCT method should be preferred to avoid geographical misses and ensure optimal treatment outcomes. However, our conclusion may be limited by the technique we employed.","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/acm2.14532","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

Abstract

BackgroundStereotactic ablative body radiation (SABR) is a well‐recognized treatment option for hepatocellular carcinoma (HCC). Due to the inherent motion of liver tumors, effective motion management is crucial for successful SABR. In the motion‐encompassing motion management technique, all 10 respiratory phase image datasets are delineated and designated as the internal target volume (ITV). Some treatment centers use single or combination image sets to delineate the target volume. This study determines which specialty image set most closely matches an all‐phase ITV contour on a synchronized contrast‐enhanced 4DCT.Materials and methodsSynchronized 4DCT contrast and delayed scans were acquired for 10 patients in the study. The maximum intensity projection (MiP), average intensity projection (AvgIP), and minimum intensity projection (MinIP) images were generated. The ITV delineation was done in all 10 phases (ITV_all_phase). The ITV_2phase combines the peak inhale and exhale phase, ITV_2 M combines MiP and MinIP, and ITV_3 M combines MiP, MinIP, and AvgIP. All ITVs were compared to ITV_all_phase with Dice similarity index (DSI) and volumes.ResultsUsing ITV_all_phase as the reference, the DSI and the mean ITV volumes for the different ITVs were as follows: ITV_all_phase (1 and 116.69 cc), ITV_2phase (0.87 and 105.27 cc), MiP (0.76 and 98.24 cc), AvgIP (0.72 and 94.54 cc), ITV_MinIP (0.67 and 81.08 cc), ITV_2 M (0.84 and 106.26 cc), and ITV_3 M (0.86 and 112.51 cc).ConclusionThe study demonstrates that in the motion‐encompassing technique of motion management, the target volume generated by delineating all phases of 4DCT provides the most accurate representation for patients with HCC. Specialty image sets and their combinations, while sometimes close, tend to result in less accurate targeting. Hence, the all‐phase 4DCT method should be preferred to avoid geographical misses and ensure optimal treatment outcomes. However, our conclusion may be limited by the technique we employed.
全阶段 ITV(内部靶体积)是肝细胞癌目标定义的金标准吗?
背景立体定向烧蚀体放射治疗(SABR)是公认的肝细胞癌(HCC)治疗方法。由于肝脏肿瘤固有的运动特性,有效的运动管理对 SABR 的成功至关重要。在运动包络运动管理技术中,所有 10 个呼吸相位图像数据集都被划定并指定为内部靶体积(ITV)。一些治疗中心使用单一或组合图像集来划定目标容积。本研究确定了哪种专业图像集最接近同步对比增强 4DCT 上的全相 ITV 轮廓。生成最大强度投影(MiP)、平均强度投影(AvgIP)和最小强度投影(MinIP)图像。所有 10 个阶段(ITV_all_phase)都进行了 ITV 划分。ITV_2phase 结合了吸气和呼气的峰值阶段,ITV_2 M 结合了 MiP 和 MinIP,ITV_3 M 结合了 MiP、MinIP 和 AvgIP。结果以 ITV_all_phase 为参照,不同 ITV 的 DSI 和平均 ITV 容量如下:ITV_all_phase(1 和 116.69 毫升)、ITV_2phase(0.87 和 105.27 毫升)、MiP(0.76 和 98.24 毫升)、AvgIP(0.72 和 94.54 毫升)、ITV_MinIP(0.67 和 81.08 毫升)、ITV_2 M(0.84 和 106.26 毫升)以及 ITV_3 M(0.86 和 112.51 毫升)。结论该研究表明,在运动管理的运动包络技术中,通过划定 4DCT 的所有阶段而生成的目标体积能最准确地显示 HCC 患者的情况。专业图像集及其组合虽然有时很接近,但往往导致目标定位不够准确。因此,应首选全相位 4DCT 方法,以避免地理漏诊,确保最佳治疗效果。不过,我们的结论可能会受到我们所采用的技术的限制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信