810. ROBOTIC ASSISTED CISTERNA CHYLI EMBOLIZATION FOR ABDOMINAL CHYLE LEAKAGE AFTER IVOR LEWIS ESOPHAGECTOMY

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS
Laurens Denissen, Jody Valk, Thomas Jardinet, Michiel de Maat
{"title":"810. ROBOTIC ASSISTED CISTERNA CHYLI EMBOLIZATION FOR ABDOMINAL CHYLE LEAKAGE AFTER IVOR LEWIS ESOPHAGECTOMY","authors":"Laurens Denissen, Jody Valk, Thomas Jardinet, Michiel de Maat","doi":"10.1093/dote/doae057.404","DOIUrl":null,"url":null,"abstract":"Background High output chyle leakage is a challenging complication following esophagectomy, carrying substantial morbidity and even mortality. Initial conservative management with parenteral feeding is commonly advised resulting in lengthy episodes of hospitalization and prolonged chest tube placement. Here, we present a case post Ivor-Lewis esophagectomy with high-output chyle leakage where we localized the leakage site to be at the cysterna chyli and subsequently treated it operatively combining robotics, fluorescence and embolization with glue. Methods A 74-year-old male underwent robotic-assisted minimally invasive Ivor Lewis esophagectomy for distal esophageal adenocarcinoma. Postoperatively, chylous fluid was drained from the chest up to 700-1300cc per day despite parenteral feeding. Lipiodol lymphangiography identified extravasation of contrast at the cysterna chyli and correct clipping of the thoracic duct. Due to failure of conservative management, on postoperative day 14, robotic-assisted exploration of the truncal region with intranodal injection of indocyanine green was performed. Results This innovative procedure revealed the leakage site medially of the coeliac trunc at the cysterna chyli. Lymphatic sealing was achieved via percutaneous endoluminal embolization using a microcatheter and Histoacryl® injections, resulting in an abrupt resolution of the leak and discharge with oral MCT diet on day 5 after reoperation. Conclusion This case demonstrated the feasibility and efficacy of an innovative multimodal technique combining the dexterity and fluorescence of robotic surgery with a laparoscopic application of an interventional radiology embolization technique. Because of the risk of venous emboli, we note that this technique should only be applied in cases of abdominal chyle leakage when the thoracic duct is interrupted. https://www.dropbox.com/scl/fi/sktltdc1be41jfq4dk3lt/Video-Presentation-ISDE-2024-Robotic-Embolisation-Abdominal-Chyle-leakage-Def.mp4?rlkey=1wni1dpnjg4swiajcjdfa6isn&st=wx30jbi7&dl=0","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-09-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/dote/doae057.404","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

Abstract

Background High output chyle leakage is a challenging complication following esophagectomy, carrying substantial morbidity and even mortality. Initial conservative management with parenteral feeding is commonly advised resulting in lengthy episodes of hospitalization and prolonged chest tube placement. Here, we present a case post Ivor-Lewis esophagectomy with high-output chyle leakage where we localized the leakage site to be at the cysterna chyli and subsequently treated it operatively combining robotics, fluorescence and embolization with glue. Methods A 74-year-old male underwent robotic-assisted minimally invasive Ivor Lewis esophagectomy for distal esophageal adenocarcinoma. Postoperatively, chylous fluid was drained from the chest up to 700-1300cc per day despite parenteral feeding. Lipiodol lymphangiography identified extravasation of contrast at the cysterna chyli and correct clipping of the thoracic duct. Due to failure of conservative management, on postoperative day 14, robotic-assisted exploration of the truncal region with intranodal injection of indocyanine green was performed. Results This innovative procedure revealed the leakage site medially of the coeliac trunc at the cysterna chyli. Lymphatic sealing was achieved via percutaneous endoluminal embolization using a microcatheter and Histoacryl® injections, resulting in an abrupt resolution of the leak and discharge with oral MCT diet on day 5 after reoperation. Conclusion This case demonstrated the feasibility and efficacy of an innovative multimodal technique combining the dexterity and fluorescence of robotic surgery with a laparoscopic application of an interventional radiology embolization technique. Because of the risk of venous emboli, we note that this technique should only be applied in cases of abdominal chyle leakage when the thoracic duct is interrupted. https://www.dropbox.com/scl/fi/sktltdc1be41jfq4dk3lt/Video-Presentation-ISDE-2024-Robotic-Embolisation-Abdominal-Chyle-leakage-Def.mp4?rlkey=1wni1dpnjg4swiajcjdfa6isn&st=wx30jbi7&dl=0
810.机器人辅助糜烂栓塞术治疗伊沃-路易斯食管切除术后的腹腔糜烂渗漏
背景 高输出量糜烂性渗漏是食管切除术后的一种棘手并发症,具有很高的发病率甚至死亡率。最初的保守治疗通常建议使用肠外喂养,结果导致长时间住院和胸管置入时间延长。在此,我们介绍了一例 Ivor-Lewis 食管切除术后高输出糜烂性渗漏病例,我们将渗漏部位定位在糜烂膀胱,随后结合机器人、荧光和胶水栓塞进行了手术治疗。方法 一位 74 岁的男性因食管远端腺癌接受了机器人辅助微创 Ivor Lewis 食管切除术。术后,尽管进行了肠外喂养,但每天从胸部排出的乳糜液仍高达 700-1300cc 。脂肪碘淋巴管造影发现造影剂在糜烂宫颈处外渗,并对胸导管进行了正确的剪切。由于保守治疗无效,在术后第 14 天,患者在机器人辅助下对躯干区域进行了探查,并在结节内注射了吲哚菁绿。结果 这一创新手术发现了位于糜烂囊内侧的腹腔截尾内侧漏点。通过使用微导管进行经皮腔内栓塞和注射 Histoacryl® 实现了淋巴密封,结果渗漏突然消失,并在再次手术后第 5 天通过口服 MCT 饮食出院。结论 本病例展示了一种创新的多模式技术的可行性和有效性,该技术结合了机器人手术的灵巧性和荧光性,以及介入放射学栓塞技术的腹腔镜应用。由于存在静脉栓塞的风险,我们注意到该技术仅适用于胸导管中断的腹腔糜烂渗漏病例。https://www.dropbox.com/scl/fi/sktltdc1be41jfq4dk3lt/Video-Presentation-ISDE-2024-Robotic-Embolisation-Abdominal-Chyle-leakage-Def.mp4?rlkey=1wni1dpnjg4swiajcjdfa6isn&st=wx30jbi7&dl=0
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信