An evaluation of atmospheric absorption models at millimetre and sub-millimetre wavelengths using airborne observations

IF 3.2 3区 地球科学 Q2 METEOROLOGY & ATMOSPHERIC SCIENCES
Stuart Fox, Vinia Mattioli, Emma Turner, Alan Vance, Domenico Cimini, Donatello Gallucci
{"title":"An evaluation of atmospheric absorption models at millimetre and sub-millimetre wavelengths using airborne observations","authors":"Stuart Fox, Vinia Mattioli, Emma Turner, Alan Vance, Domenico Cimini, Donatello Gallucci","doi":"10.5194/amt-17-4957-2024","DOIUrl":null,"url":null,"abstract":"Abstract. Accurate gas absorption models at millimetre and sub-millimetre wavelengths are required to make best use of observations from instruments on board the next generation of EUMETSAT polar-orbiting weather satellites, including the Ice Cloud Imager (ICI), which measures at frequencies up to 664 GHz. In this study, airborne observations of clear-sky scenes between 89 and 664 GHz are used to perform radiative closure calculations for both upward- and downward-looking viewing directions in order to evaluate two state-of-the-art absorption models, both of which are integrated into the Atmospheric Radiative Transfer Simulator (ARTS). Differences of 20 K are seen in some individual comparisons, with the largest discrepancies occurring where the brightness temperature is highly sensitive to the atmospheric water vapour profile. However, these differences are within the expected uncertainty due to the observed water vapour variability, highlighting the importance of understanding the spatial and temporal distribution of water vapour when performing such comparisons. The errors can be significantly reduced by averaging across multiple flights, which reduces the impact of uncertainties in individual atmospheric profiles. For upward-looking views, which have the greatest sensitivity to the absorption model, the mean differences between observed and simulated brightness temperatures are generally close to, or within, the estimated spectroscopic uncertainty. For downward-looking views, which more closely match the satellite viewing geometry, the mean differences were generally less than 1.5 K, with the exception of window channels at 89 and 157 GHz, which are significantly influenced by surface properties. These results suggest that both of the absorption models considered are sufficiently accurate for use with ICI.","PeriodicalId":8619,"journal":{"name":"Atmospheric Measurement Techniques","volume":"217 1","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2024-08-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Atmospheric Measurement Techniques","FirstCategoryId":"89","ListUrlMain":"https://doi.org/10.5194/amt-17-4957-2024","RegionNum":3,"RegionCategory":"地球科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"METEOROLOGY & ATMOSPHERIC SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract. Accurate gas absorption models at millimetre and sub-millimetre wavelengths are required to make best use of observations from instruments on board the next generation of EUMETSAT polar-orbiting weather satellites, including the Ice Cloud Imager (ICI), which measures at frequencies up to 664 GHz. In this study, airborne observations of clear-sky scenes between 89 and 664 GHz are used to perform radiative closure calculations for both upward- and downward-looking viewing directions in order to evaluate two state-of-the-art absorption models, both of which are integrated into the Atmospheric Radiative Transfer Simulator (ARTS). Differences of 20 K are seen in some individual comparisons, with the largest discrepancies occurring where the brightness temperature is highly sensitive to the atmospheric water vapour profile. However, these differences are within the expected uncertainty due to the observed water vapour variability, highlighting the importance of understanding the spatial and temporal distribution of water vapour when performing such comparisons. The errors can be significantly reduced by averaging across multiple flights, which reduces the impact of uncertainties in individual atmospheric profiles. For upward-looking views, which have the greatest sensitivity to the absorption model, the mean differences between observed and simulated brightness temperatures are generally close to, or within, the estimated spectroscopic uncertainty. For downward-looking views, which more closely match the satellite viewing geometry, the mean differences were generally less than 1.5 K, with the exception of window channels at 89 and 157 GHz, which are significantly influenced by surface properties. These results suggest that both of the absorption models considered are sufficiently accurate for use with ICI.
利用机载观测对毫米和亚毫米波长大气吸收模型进行评估
摘要。要充分利用欧洲气象卫星应用组织下一代极轨气象卫星(包括频率高达 664 千兆赫的冰云成像仪)所搭载仪器的观测结果,就必须建立精确的毫米和亚毫米波长气体吸收模型。在这项研究中,利用对 89 和 664 GHz 之间晴空场景的机载观测,对向上和向下观测方向进行了辐射闭合计算,以评估两种最先进的吸收模型,这两种模型都已集成到大气辐射传输模拟器(ARTS)中。在一些单独的比较中,发现了 20 千卡的差异,其中最大的差异出现在亮度温度对大气水蒸气剖面高度敏感的地方。不过,由于观测到的水蒸气变化,这些差异都在预期的不确定性范围内,这突出表明了在进行此类比较时了解水蒸气时空分布的重要性。通过对多个飞行进行平均,可以大大减少误差,从而降低单个大气剖面不确定性的影响。对于对吸收模式最敏感的向上观测视角,观测和模拟亮度温度之间的平均差异通常接近或在估计的光谱不确定性范围内。对于更接近卫星观测几何形状的向下观测视图,平均差异一般小于 1.5 K,但 89 和 157 GHz 窗口通道除外,因为它们受表面特性的影响很大。这些结果表明,所考虑的两个吸收模型都足够准确,可用于 ICI。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Atmospheric Measurement Techniques
Atmospheric Measurement Techniques METEOROLOGY & ATMOSPHERIC SCIENCES-
CiteScore
7.10
自引率
18.40%
发文量
331
审稿时长
3 months
期刊介绍: Atmospheric Measurement Techniques (AMT) is an international scientific journal dedicated to the publication and discussion of advances in remote sensing, in-situ and laboratory measurement techniques for the constituents and properties of the Earth’s atmosphere. The main subject areas comprise the development, intercomparison and validation of measurement instruments and techniques of data processing and information retrieval for gases, aerosols, and clouds. The manuscript types considered for peer-reviewed publication are research articles, review articles, and commentaries.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信