Simultaneous measurement of greenhouse gases (CH4, CO2 and N2O) at atmospheric levels using a gas chromatography system

IF 3.2 3区 地球科学 Q2 METEOROLOGY & ATMOSPHERIC SCIENCES
Michal Bucha, Dominika Lewicka-Szczebak, Piotr Wójtowicz
{"title":"Simultaneous measurement of greenhouse gases (CH4, CO2 and N2O) at atmospheric levels using a gas chromatography system","authors":"Michal Bucha, Dominika Lewicka-Szczebak, Piotr Wójtowicz","doi":"10.5194/egusphere-2024-2125","DOIUrl":null,"url":null,"abstract":"<strong>Abstract.</strong> This article presents a simple method for determining greenhouse gases (CH<sub>4</sub>, CO<sub>2</sub>, N<sub>2</sub>O) at ambient atmospheric levels using a chromatographic system. The novelty of the presented method is the application of a Carboxen 1010 PLOT capillary column for separation of trace gases – CH<sub>4</sub>, CO<sub>2</sub> and N<sub>2</sub>O – from air samples and their detection using a barrier discharge ionisation detector (BID). Simultaneously, a parallel molecular sieve column connected to a thermal conductivity detector (TCD) allowed the determination of CH<sub>4</sub>, N<sub>2</sub> and O<sub>2</sub> concentrations from 0.1 to 100 %. The system was equipped with an autosampler transferring the samples without air contamination thanks to a vacuum pump-inert gas flushing option. Method validation was performed using commercial gas standards and undertaking a comparison measurement with a reference method: optical methods applying Picarro isotope and concentration instruments with cavity ring-down spectroscopy for CO<sub>2</sub>, CH<sub>4</sub> and N<sub>2</sub>O. A three-day continuous measurement series of the lowest GHG concentrations in ambient air and tests of typical vial sample measurements with increased GHG concentrations were performed. The advantage of this method is that the system is easy to set up and allows for simultaneous detection and analysis of the main GHGs in their ambient concentrations using one GC column and one detector, thereby omitting the need for an electron capture detector (ECD) containing radiogenic components for N<sub>2</sub>O analysis and a flame ionisation detector (FID) with a methaniser for low-concentration CO<sub>2</sub> samples. The simplification of the system reduces analytical costs, facilitates instrument maintenance and improves measurement robustness.","PeriodicalId":8619,"journal":{"name":"Atmospheric Measurement Techniques","volume":"31 1","pages":""},"PeriodicalIF":3.2000,"publicationDate":"2024-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Atmospheric Measurement Techniques","FirstCategoryId":"89","ListUrlMain":"https://doi.org/10.5194/egusphere-2024-2125","RegionNum":3,"RegionCategory":"地球科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"METEOROLOGY & ATMOSPHERIC SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract. This article presents a simple method for determining greenhouse gases (CH4, CO2, N2O) at ambient atmospheric levels using a chromatographic system. The novelty of the presented method is the application of a Carboxen 1010 PLOT capillary column for separation of trace gases – CH4, CO2 and N2O – from air samples and their detection using a barrier discharge ionisation detector (BID). Simultaneously, a parallel molecular sieve column connected to a thermal conductivity detector (TCD) allowed the determination of CH4, N2 and O2 concentrations from 0.1 to 100 %. The system was equipped with an autosampler transferring the samples without air contamination thanks to a vacuum pump-inert gas flushing option. Method validation was performed using commercial gas standards and undertaking a comparison measurement with a reference method: optical methods applying Picarro isotope and concentration instruments with cavity ring-down spectroscopy for CO2, CH4 and N2O. A three-day continuous measurement series of the lowest GHG concentrations in ambient air and tests of typical vial sample measurements with increased GHG concentrations were performed. The advantage of this method is that the system is easy to set up and allows for simultaneous detection and analysis of the main GHGs in their ambient concentrations using one GC column and one detector, thereby omitting the need for an electron capture detector (ECD) containing radiogenic components for N2O analysis and a flame ionisation detector (FID) with a methaniser for low-concentration CO2 samples. The simplification of the system reduces analytical costs, facilitates instrument maintenance and improves measurement robustness.
利用气相色谱系统同时测量大气中的温室气体(CH4、CO2 和 N2O
摘要本文介绍了一种利用色谱系统测定环境大气中温室气体(CH4、CO2、N2O)含量的简单方法。该方法的新颖之处在于采用 Carboxen 1010 PLOT 毛细管色谱柱分离空气样品中的痕量气体(CH4、CO2 和 N2O),并使用阻挡放电离子化检测器 (BID) 进行检测。与此同时,与热导检测器(TCD)相连的平行分子筛色谱柱可测定 0.1 % 至 100 % 的 CH4、N2 和 O2 浓度。该系统配备了一个自动进样器,通过真空泵-惰性气体冲洗选项传输样品,不会造成空气污染。使用商用气体标准进行了方法验证,并与参考方法进行了对比测量:采用光学方法,使用 Picarro 同位素和浓度仪器以及空腔降环光谱法测量 CO2、CH4 和 N2O。对环境空气中最低温室气体浓度进行了为期三天的连续测量,并对温室气体浓度增加时的典型小瓶样品测量进行了测试。该方法的优点是系统设置简单,使用一个气相色谱柱和一个检测器就能同时检测和分析环境中主要温室气体的浓度,从而省去了用于分析一氧化二氮的含有辐射成分的电子捕获检测器(ECD)和用于分析低浓度二氧化碳样品的带有甲烷化器的火焰离子化检测器(FID)。系统的简化降低了分析成本,方便了仪器维护,提高了测量的稳定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Atmospheric Measurement Techniques
Atmospheric Measurement Techniques METEOROLOGY & ATMOSPHERIC SCIENCES-
CiteScore
7.10
自引率
18.40%
发文量
331
审稿时长
3 months
期刊介绍: Atmospheric Measurement Techniques (AMT) is an international scientific journal dedicated to the publication and discussion of advances in remote sensing, in-situ and laboratory measurement techniques for the constituents and properties of the Earth’s atmosphere. The main subject areas comprise the development, intercomparison and validation of measurement instruments and techniques of data processing and information retrieval for gases, aerosols, and clouds. The manuscript types considered for peer-reviewed publication are research articles, review articles, and commentaries.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信