Wearable Perovskite Films for On-Line Monitoring of Radiotracers in Nuclear Medicine

Laura Basiricò, Matteo Verdi, Andrea Ciavatti, Lorenzo Piergallini, Elisa Grassi, Federica Fioroni, Lorenzo Margotti, Nicolò Tosi, Valentina Cicero, Alessandro Montanari, Mauro Iori, Beatrice Fraboni
{"title":"Wearable Perovskite Films for On-Line Monitoring of Radiotracers in Nuclear Medicine","authors":"Laura Basiricò, Matteo Verdi, Andrea Ciavatti, Lorenzo Piergallini, Elisa Grassi, Federica Fioroni, Lorenzo Margotti, Nicolò Tosi, Valentina Cicero, Alessandro Montanari, Mauro Iori, Beatrice Fraboni","doi":"10.1002/admt.202401111","DOIUrl":null,"url":null,"abstract":"On-line in situ monitoring of radiation emitted by radiotracers during intravenous injection is of crucial importance for the safety of patients and personnel involved in nuclear medicine treatments and analysis. The aim of this work is to assess wearable perovskite ionizing radiation detectors for such application. With this purpose pixelated direct detector based on thin films of 2D layered perovskite PEA<sub>2</sub>PbBr<sub>4</sub> are tested for the monitoring of gamma-rays emitted by <sup>18</sup>F radiopharmaceutical under different experimental conditions. The wearable detector is here demonstrated being able to detect in real-time the gamma-rays emitted by annihilation of <sup>18</sup>F radiotracer. Its reliability is assessed by <sup>18</sup>F half-life measurement with a maximum accuracy deviation within 8%. The detector also successes in its validation for the foreseen application, demonstrating able to monitor in real-time the whole injection process and extravasation event.","PeriodicalId":7200,"journal":{"name":"Advanced Materials & Technologies","volume":"15 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-08-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advanced Materials & Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/admt.202401111","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

On-line in situ monitoring of radiation emitted by radiotracers during intravenous injection is of crucial importance for the safety of patients and personnel involved in nuclear medicine treatments and analysis. The aim of this work is to assess wearable perovskite ionizing radiation detectors for such application. With this purpose pixelated direct detector based on thin films of 2D layered perovskite PEA2PbBr4 are tested for the monitoring of gamma-rays emitted by 18F radiopharmaceutical under different experimental conditions. The wearable detector is here demonstrated being able to detect in real-time the gamma-rays emitted by annihilation of 18F radiotracer. Its reliability is assessed by 18F half-life measurement with a maximum accuracy deviation within 8%. The detector also successes in its validation for the foreseen application, demonstrating able to monitor in real-time the whole injection process and extravasation event.

Abstract Image

用于核医学中放射性同位素在线监测的可穿戴 Perovskite 薄膜
对放射性同位素在静脉注射过程中发出的辐射进行在线原位监测,对参与核医学治疗和分析的病人和工作人员的安全至关重要。这项工作的目的是评估用于此类应用的可穿戴式包晶电离辐射探测器。为此,对基于二维层状包晶 PEA2PbBr4 薄膜的像素化直接探测器进行了测试,以监测 18F 放射性药物在不同实验条件下发射的伽马射线。实验证明,这种可穿戴探测器能够实时检测到 18F 放射性示踪剂湮灭所发射的伽马射线。通过 18F 半衰期测量对其可靠性进行了评估,最大精度偏差在 8%以内。该探测器还成功通过了预期应用的验证,证明能够实时监测整个注射过程和外渗事件。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信