Kevin J. Chung, Abhijit J. Chaudhari, Lorenzo Nardo, Terry Jones, Moon S. Chen, Ramsey D. Badawi, Simon R. Cherry, Guobao Wang
{"title":"Quantitative Total-Body Imaging of Blood Flow with High Temporal Resolution Early Dynamic 18F-Fluorodeoxyglucose PET Kinetic Modeling","authors":"Kevin J. Chung, Abhijit J. Chaudhari, Lorenzo Nardo, Terry Jones, Moon S. Chen, Ramsey D. Badawi, Simon R. Cherry, Guobao Wang","doi":"10.1101/2024.08.30.24312867","DOIUrl":null,"url":null,"abstract":"Quantitative total-body PET imaging of blood flow can be performed with freely diffusible flow radiotracers such as <sup>15</sup>O-water and <sup>11</sup>C-butanol, but their short half-lives necessitate close access to a cyclotron. Past efforts to measure blood flow with the widely available radiotracer <sup>18</sup>F-fluorodeoxyglucose (FDG) were limited to tissues with high <sup>18</sup>F-FDG extraction fraction. In this study, we developed an early-dynamic <sup>18</sup>F-FDG PET method with high temporal resolution kinetic modeling to assess total-body blood flow based on deriving the vascular transit time of <sup>18</sup>F-FDG and conducted a pilot comparison study against a <sup>11</sup>C-butanol reference.","PeriodicalId":501358,"journal":{"name":"medRxiv - Radiology and Imaging","volume":"30 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"medRxiv - Radiology and Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1101/2024.08.30.24312867","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Quantitative total-body PET imaging of blood flow can be performed with freely diffusible flow radiotracers such as 15O-water and 11C-butanol, but their short half-lives necessitate close access to a cyclotron. Past efforts to measure blood flow with the widely available radiotracer 18F-fluorodeoxyglucose (FDG) were limited to tissues with high 18F-FDG extraction fraction. In this study, we developed an early-dynamic 18F-FDG PET method with high temporal resolution kinetic modeling to assess total-body blood flow based on deriving the vascular transit time of 18F-FDG and conducted a pilot comparison study against a 11C-butanol reference.