{"title":"Assessing Venous Thrombotic Risks in Extracorporeal Membrane Oxygenation-Supported Patients: A Systematic Review and Meta-Analysis.","authors":"Yan Zhu, Mei-Juan Lan, Jiang-Shu-Yuan Liang, Ling-Yun Cai, Lu-Yao Guo, Pei-Pei Gu, Fei Zeng","doi":"10.1177/10760296241279293","DOIUrl":null,"url":null,"abstract":"<p><p>This study investigates the prevalence and risk factors associated with venous thrombotic events in patients receiving (ECMO) support. Systematic review and meta-analysis of case-control and cohort studies. PubMed, Cochrane Library, Embase, CINAHL, Web of Science, Scopus, and ProQuest databases from inception through November 25, 2023.Case-control and cohort studies focusing on the prevalence and risk factors for venous thrombotic events in patients supported by ECMO. Identification of risk factors and calculation of incidence rates. Nineteen studies encompassing 10,767 participants were identified and included in the analysis. The pooled prevalence of venous thrombotic events among patients receiving ECMO support was 48% [95% confidence interval (CI) 0.37-0.60, I<sup>2 </sup>= 97.18%]. Factors associated with increased incidence rates included longer duration of ECMO support (odds ratio [OR] 1.08, 95% CI 1.07-1.09, I<sup>2 </sup>= 49%), abnormal anti-coagulation monitoring indicators (OR 1.02, 95% CI 1.00-1.04, I<sup>2 = </sup>84%), and type of ECMO cannulation (OR 1.77, 95% CI 1.14-3.34, I<sup>2 </sup>= 64%). The pooled prevalence of venous thrombotic events in patients with ECMO support is high. Increased risk is associated with extended duration of ECMO support, abnormal anti-coagulation monitoring, and specific types of ECMO cannulation.</p>","PeriodicalId":10335,"journal":{"name":"Clinical and Applied Thrombosis/Hemostasis","volume":"30 ","pages":"10760296241279293"},"PeriodicalIF":2.3000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11388296/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical and Applied Thrombosis/Hemostasis","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/10760296241279293","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"HEMATOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

This study investigates the prevalence and risk factors associated with venous thrombotic events in patients receiving (ECMO) support. Systematic review and meta-analysis of case-control and cohort studies. PubMed, Cochrane Library, Embase, CINAHL, Web of Science, Scopus, and ProQuest databases from inception through November 25, 2023.Case-control and cohort studies focusing on the prevalence and risk factors for venous thrombotic events in patients supported by ECMO. Identification of risk factors and calculation of incidence rates. Nineteen studies encompassing 10,767 participants were identified and included in the analysis. The pooled prevalence of venous thrombotic events among patients receiving ECMO support was 48% [95% confidence interval (CI) 0.37-0.60, I2 = 97.18%]. Factors associated with increased incidence rates included longer duration of ECMO support (odds ratio [OR] 1.08, 95% CI 1.07-1.09, I2 = 49%), abnormal anti-coagulation monitoring indicators (OR 1.02, 95% CI 1.00-1.04, I2 = 84%), and type of ECMO cannulation (OR 1.77, 95% CI 1.14-3.34, I2 = 64%). The pooled prevalence of venous thrombotic events in patients with ECMO support is high. Increased risk is associated with extended duration of ECMO support, abnormal anti-coagulation monitoring, and specific types of ECMO cannulation.

评估体外膜氧合患者静脉血栓风险:系统回顾与元分析》。
本研究调查了接受(ECMO)支持的患者静脉血栓事件的发生率和相关风险因素。对病例对照和队列研究进行系统回顾和荟萃分析。PubMed、Cochrane Library、Embase、CINAHL、Web of Science、Scopus 和 ProQuest 数据库(从开始到 2023 年 11 月 25 日)。病例对照和队列研究侧重于 ECMO 支持患者静脉血栓事件的流行率和风险因素。确定风险因素并计算发病率。共确定了 19 项研究,涵盖 10,767 名参与者,并将其纳入分析。在接受 ECMO 支持的患者中,静脉血栓事件的总发生率为 48% [95% 置信区间 (CI) 0.37-0.60,I2 = 97.18%]。与发病率增加相关的因素包括:ECMO 支持时间较长(比值比 [OR] 1.08,95% CI 1.07-1.09,I2 = 49%)、抗凝监测指标异常(OR 1.02,95% CI 1.00-1.04,I2 = 84%)和 ECMO 插管类型(OR 1.77,95% CI 1.14-3.34,I2 = 64%)。接受 ECMO 支持的患者静脉血栓事件的总体发生率较高。风险增加与 ECMO 支持时间延长、抗凝监测异常和特定类型的 ECMO 插管有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.40
自引率
3.40%
发文量
150
审稿时长
2 months
期刊介绍: CATH is a peer-reviewed bi-monthly journal that addresses the practical clinical and laboratory issues involved in managing bleeding and clotting disorders, especially those related to thrombosis, hemostasis, and vascular disorders. CATH covers clinical trials, studies on etiology, pathophysiology, diagnosis and treatment of thrombohemorrhagic disorders.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信