Amir behjat, Abdollah Saboori, Manuela Galati, Luca Iuliano
{"title":"The electrochemical behaviour of Ti-48Al-2Cr-2Nb produced by electron beam powder bed fusion process","authors":"Amir behjat, Abdollah Saboori, Manuela Galati, Luca Iuliano","doi":"10.1016/j.intermet.2024.108472","DOIUrl":null,"url":null,"abstract":"<div><p>Titanium aluminides (TiAl) are distinguished by their exceptional strength-to-weight ratio, making them ideal for aerospace and medical applications. Notably, TiAl alloys offer a unique combination of high-temperature resistance and corrosion resilience, contributing to their growing prominence in advanced engineering and biomedical fields. Although initially developed for aerospace applications, TiAl alloys have demonstrated promising potential as implant materials over time. Hence, this research focuses on producing γ-TiAl alloy through electron beam powder bed fusion (EB-PBF) technology, utilising a powder with a composition of Ti-48Al-2Cr-2Nb. For comparative purposes, the corrosion characteristics of Ti6Al4V produced via EB-PBF were also evaluated under identical conditions. The findings indicate that the EB-PBF γ-TiAl exhibits exceptional resistance to corrosion. This is supported by the significantly high polarisation resistance and corrosion potential values, as well as the notably low corrosion current value. However, based on the analysis of the polarisation and impedance curves, it can be observed that the γ-TiAl sample displayed a less protective passive film formation. This occurrence can be attributed to the presence of aluminium ions within the passive layer, resulting in the formation of unstable oxides. As a consequence, it can be inferred that γ-TiAl exhibits inferior resistance to pitting corrosion when compared to Ti6Al4V alloy. The point defect model and Mott-Schottky test further revealed that the γ-TiAl alloy exhibited increased oxygen vacancies. Additionally, the presence of aluminium ions as impurities or dopants led to their substitution for titanium ions, creating cationic vacancies within the passive film. The accumulation of excessive cation vacancies ultimately led to the initiation of pitting corrosion.</p></div>","PeriodicalId":331,"journal":{"name":"Intermetallics","volume":"175 ","pages":"Article 108472"},"PeriodicalIF":4.3000,"publicationDate":"2024-09-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0966979524002917/pdfft?md5=4a36388d7a8693ea2a1eeeb489815b66&pid=1-s2.0-S0966979524002917-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Intermetallics","FirstCategoryId":"88","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0966979524002917","RegionNum":2,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Titanium aluminides (TiAl) are distinguished by their exceptional strength-to-weight ratio, making them ideal for aerospace and medical applications. Notably, TiAl alloys offer a unique combination of high-temperature resistance and corrosion resilience, contributing to their growing prominence in advanced engineering and biomedical fields. Although initially developed for aerospace applications, TiAl alloys have demonstrated promising potential as implant materials over time. Hence, this research focuses on producing γ-TiAl alloy through electron beam powder bed fusion (EB-PBF) technology, utilising a powder with a composition of Ti-48Al-2Cr-2Nb. For comparative purposes, the corrosion characteristics of Ti6Al4V produced via EB-PBF were also evaluated under identical conditions. The findings indicate that the EB-PBF γ-TiAl exhibits exceptional resistance to corrosion. This is supported by the significantly high polarisation resistance and corrosion potential values, as well as the notably low corrosion current value. However, based on the analysis of the polarisation and impedance curves, it can be observed that the γ-TiAl sample displayed a less protective passive film formation. This occurrence can be attributed to the presence of aluminium ions within the passive layer, resulting in the formation of unstable oxides. As a consequence, it can be inferred that γ-TiAl exhibits inferior resistance to pitting corrosion when compared to Ti6Al4V alloy. The point defect model and Mott-Schottky test further revealed that the γ-TiAl alloy exhibited increased oxygen vacancies. Additionally, the presence of aluminium ions as impurities or dopants led to their substitution for titanium ions, creating cationic vacancies within the passive film. The accumulation of excessive cation vacancies ultimately led to the initiation of pitting corrosion.
期刊介绍:
This journal is a platform for publishing innovative research and overviews for advancing our understanding of the structure, property, and functionality of complex metallic alloys, including intermetallics, metallic glasses, and high entropy alloys.
The journal reports the science and engineering of metallic materials in the following aspects:
Theories and experiments which address the relationship between property and structure in all length scales.
Physical modeling and numerical simulations which provide a comprehensive understanding of experimental observations.
Stimulated methodologies to characterize the structure and chemistry of materials that correlate the properties.
Technological applications resulting from the understanding of property-structure relationship in materials.
Novel and cutting-edge results warranting rapid communication.
The journal also publishes special issues on selected topics and overviews by invitation only.