{"title":"The surgical outcome of sutureless skin closures using Octyl-2-cyanoacrylate (Dermabond™) versus Steri-Strip™.","authors":"Neha Sah, Rohit Punga, Ajay Kumar, Peeyush Shivhare, Akhilesh Kumar Singh, Sonam Sah, Amlendu Shekhar","doi":"10.4103/njms.njms_102_22","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Cosmesis is the primary concern for the patient undergoing facial surgery and there are numbers of well proven materials that are available such as adhesive tapes, subcuticular suture, skin adhesive or glue to achieve better cosmesis. The objective of our study was to assess the surgical outcome of sutureless skin closures using Octyl-2-cyanoacrylate (Dermabond™) versus Steri-Strip™.</p><p><strong>Method: </strong>The present prospective study was conducted in 20 patients. Patients were divided into two groups. After subcutaneous closure of wounds, either Dermabond™ or Steri-Strip™ was placed. The patients were assessed for wound complication (erythema, tenderness, dehiscence or any discharge), scar hypertrophy and cosmetic appearance also time consumed in surgical skin closure was evaluated. Wound assessment, scar hypertrophy and cosmetic appearance were assessed by using Chi-square test. Time closure was assessed by using Mann-whitney U test.</p><p><strong>Result: </strong>Twenty patients belonging to all age group were included in study. Ten patients undergone closure with Dermabond™ and ten with Steri-Strips™. Assessment of wound complications, cosmetic appearance and scar hypertrophy was done. There was no significant difference found between both the groups, but 2 patients had fair cosmetic outcomes at one month and 1 patient had fair scar hypertrophy at 6 month. However, excellent cosmetic outcome in terms of scar hypertrophy at 6 month was significantly more among group II.</p><p><strong>Conclusion: </strong>Octyl-2-cyanoacrylate (Dermabond™) and Steri-Strip™ provide similar outcomes in terms of wound complications. Cosmetic outcomes in terms of scar hypertrophy with steri-strip wound closure seem to be better and more economical.</p>","PeriodicalId":101444,"journal":{"name":"National journal of maxillofacial surgery","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11371292/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"National journal of maxillofacial surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/njms.njms_102_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/24 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: Cosmesis is the primary concern for the patient undergoing facial surgery and there are numbers of well proven materials that are available such as adhesive tapes, subcuticular suture, skin adhesive or glue to achieve better cosmesis. The objective of our study was to assess the surgical outcome of sutureless skin closures using Octyl-2-cyanoacrylate (Dermabond™) versus Steri-Strip™.
Method: The present prospective study was conducted in 20 patients. Patients were divided into two groups. After subcutaneous closure of wounds, either Dermabond™ or Steri-Strip™ was placed. The patients were assessed for wound complication (erythema, tenderness, dehiscence or any discharge), scar hypertrophy and cosmetic appearance also time consumed in surgical skin closure was evaluated. Wound assessment, scar hypertrophy and cosmetic appearance were assessed by using Chi-square test. Time closure was assessed by using Mann-whitney U test.
Result: Twenty patients belonging to all age group were included in study. Ten patients undergone closure with Dermabond™ and ten with Steri-Strips™. Assessment of wound complications, cosmetic appearance and scar hypertrophy was done. There was no significant difference found between both the groups, but 2 patients had fair cosmetic outcomes at one month and 1 patient had fair scar hypertrophy at 6 month. However, excellent cosmetic outcome in terms of scar hypertrophy at 6 month was significantly more among group II.
Conclusion: Octyl-2-cyanoacrylate (Dermabond™) and Steri-Strip™ provide similar outcomes in terms of wound complications. Cosmetic outcomes in terms of scar hypertrophy with steri-strip wound closure seem to be better and more economical.