{"title":"[Design and simulation study of positive pressure ventilation system in a simulated human biological lung].","authors":"Qincheng Yan, Quanyu Wu, Weimin Zhang, Lingjiao Pan, Xiaojie Liu, Weige Tao","doi":"10.7507/1001-5515.202401063","DOIUrl":null,"url":null,"abstract":"<p><p>Simulation of the human biological lung is a crucial method for medical professionals to learn and practice the use of new pulmonary interventional diagnostic and therapeutic devices. The study on ventilation effects of the simulation under positive pressure ventilation mode provide valuable guidance for clinical ventilation treatment. This study focused on establishing an electrical simulation ventilation model, which aims to address the complexities in parameter configuration and slow display of air pressure and airflow waveforms in simulating the human biological lung under positive pressure ventilation mode. A simulated ventilation experiment was conducted under pressure-regulated volume control (PRVC) positive pressure ventilation mode, and the resulting ventilation waveform was compared with that of normal adults. The experimental findings indicated that the average error of the main reference index moisture value was 9.8% under PRVC positive pressure ventilation mode, effectively simulating the ventilatory effect observed in normal adults. So the established electrical simulation ventilation model is feasible, and provides a foundation for further research on the simulation of human biological lung positive pressure ventilation experimental platform.</p>","PeriodicalId":39324,"journal":{"name":"生物医学工程学杂志","volume":"41 4","pages":"775-781"},"PeriodicalIF":0.0000,"publicationDate":"2024-08-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11366460/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"生物医学工程学杂志","FirstCategoryId":"1087","ListUrlMain":"https://doi.org/10.7507/1001-5515.202401063","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Simulation of the human biological lung is a crucial method for medical professionals to learn and practice the use of new pulmonary interventional diagnostic and therapeutic devices. The study on ventilation effects of the simulation under positive pressure ventilation mode provide valuable guidance for clinical ventilation treatment. This study focused on establishing an electrical simulation ventilation model, which aims to address the complexities in parameter configuration and slow display of air pressure and airflow waveforms in simulating the human biological lung under positive pressure ventilation mode. A simulated ventilation experiment was conducted under pressure-regulated volume control (PRVC) positive pressure ventilation mode, and the resulting ventilation waveform was compared with that of normal adults. The experimental findings indicated that the average error of the main reference index moisture value was 9.8% under PRVC positive pressure ventilation mode, effectively simulating the ventilatory effect observed in normal adults. So the established electrical simulation ventilation model is feasible, and provides a foundation for further research on the simulation of human biological lung positive pressure ventilation experimental platform.