Novel Flow Cytometry Method Detecting Complement C1q Bound to Blood Type A/B IgG Antibody for Preventing Severe Antibody-Mediated Rejection in ABO-Incompatible Kidney Transplantation.
{"title":"Novel Flow Cytometry Method Detecting Complement C1q Bound to Blood Type A/B IgG Antibody for Preventing Severe Antibody-Mediated Rejection in ABO-Incompatible Kidney Transplantation.","authors":"Tsutomu Ishizuka, Kazuhiro Iwadoh, Hiroshi Kataoka, Junichi Hoshino, Kosaku Nitta, Hideki Ishida","doi":"10.3390/antib13030062","DOIUrl":null,"url":null,"abstract":"<p><p>We aimed to develop a novel method for measuring the complement-binding ability of anti-blood type antibodies (ab-Abs), the flow cytometry method for the complement C1q test (FCM-C1q) for detecting antibody-mediated rejection (AMR) caused by ab-Abs in ABO-incompatible kidney transplantation (ABOI-KTx). FCM-C1q distribution was surveyed in 44 healthy participants and 43 dialysis patients (Cohort A). The relationship between AMR and FCM-C1q levels was examined along with ab-Ab titers by the flow cytometry method for the IgG test (FCM-IgG) in 62 ABOI-KTx patients (Cohort B). FCM-IgG and C1q levels were significantly higher in type O participants than in A/B participants in Cohort A. There were minimal differences in the distribution of FCM-IgG and C1q between dialysis and healthy participants. Sixteen cases were suspected of acute rejections (ARs) in Cohort B, of whom nine had AR clinically. One patient with severe AMR was highly suspected of hyperacute rejection along with another patient with severe AMR. Their postoperative FCM-C1q and FCM-IgG levels were elevated. Another two patients showed high FCM-IgG and C1q levels before KTx, and these levels remained low after KTx with no or mild rejection. In conclusion, our results suggest that a high positivity rate for FCM-C1q may predict moderate to severe AMR caused by ab-Abs and poor prognosis in ABOI-KTx.</p>","PeriodicalId":8188,"journal":{"name":"Antibodies","volume":"13 3","pages":""},"PeriodicalIF":3.0000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11348181/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Antibodies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/antib13030062","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"IMMUNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
We aimed to develop a novel method for measuring the complement-binding ability of anti-blood type antibodies (ab-Abs), the flow cytometry method for the complement C1q test (FCM-C1q) for detecting antibody-mediated rejection (AMR) caused by ab-Abs in ABO-incompatible kidney transplantation (ABOI-KTx). FCM-C1q distribution was surveyed in 44 healthy participants and 43 dialysis patients (Cohort A). The relationship between AMR and FCM-C1q levels was examined along with ab-Ab titers by the flow cytometry method for the IgG test (FCM-IgG) in 62 ABOI-KTx patients (Cohort B). FCM-IgG and C1q levels were significantly higher in type O participants than in A/B participants in Cohort A. There were minimal differences in the distribution of FCM-IgG and C1q between dialysis and healthy participants. Sixteen cases were suspected of acute rejections (ARs) in Cohort B, of whom nine had AR clinically. One patient with severe AMR was highly suspected of hyperacute rejection along with another patient with severe AMR. Their postoperative FCM-C1q and FCM-IgG levels were elevated. Another two patients showed high FCM-IgG and C1q levels before KTx, and these levels remained low after KTx with no or mild rejection. In conclusion, our results suggest that a high positivity rate for FCM-C1q may predict moderate to severe AMR caused by ab-Abs and poor prognosis in ABOI-KTx.
期刊介绍:
Antibodies (ISSN 2073-4468), an international, peer-reviewed open access journal which provides an advanced forum for studies related to antibodies and antigens. It publishes reviews, research articles, communications and short notes. Our aim is to encourage scientists to publish their experimental and theoretical results in as much detail as possible. There is no restriction on the length of the papers. Full experimental and/or methodical details must be provided. Electronic files or software regarding the full details of the calculation and experimental procedure - if unable to be published in a normal way - can be deposited as supplementary material. This journal covers all topics related to antibodies and antigens, topics of interest include (but are not limited to): antibody-producing cells (including B cells), antibody structure and function, antibody-antigen interactions, Fc receptors, antibody manufacturing antibody engineering, antibody therapy, immunoassays, antibody diagnosis, tissue antigens, exogenous antigens, endogenous antigens, autoantigens, monoclonal antibodies, natural antibodies, humoral immune responses, immunoregulatory molecules.