Determination of anamorelin concentration in human plasma using a simple high-performance liquid chromatography-ultraviolet detection method.

IF 1.9 Q3 PHARMACOLOGY & PHARMACY
Drug Discoveries and Therapeutics Pub Date : 2024-09-19 Epub Date: 2024-08-25 DOI:10.5582/ddt.2024.01049
Takeo Yasu, Nanami Iwatuki, Yoshito Gando, Yasuhiko Matumoto, Masahiro Masuo, Mikio Shirota, Masayoshi Kobayashi
{"title":"Determination of anamorelin concentration in human plasma using a simple high-performance liquid chromatography-ultraviolet detection method.","authors":"Takeo Yasu, Nanami Iwatuki, Yoshito Gando, Yasuhiko Matumoto, Masahiro Masuo, Mikio Shirota, Masayoshi Kobayashi","doi":"10.5582/ddt.2024.01049","DOIUrl":null,"url":null,"abstract":"<p><p>Anamorelin, a non-peptide ghrelin analog and growth hormone secretagogue, is a novel oral drug used to treat cancer cachexia. Patients with cancer cachexia frequently use several drugs and anamorelin is a substrate of cytochrome P450 (CYP) 3A4; therefore, drug-drug interactions with CYP3A4 inhibitors and inducers pose a clinical problem. In this study, we aimed to determine the concentration of anamorelin in human plasma using a simple high-performance liquid chromatography-ultraviolet (HPLC-UV)-based method. The analysis involved extracting a 200-μL plasma sample and protein precipitation using solid-phase extraction. Anamorelin was isocratically separated using a mobile phase consisting of 0.5% potassium dihydrogen phosphate (pH 4.5) and acetonitrile (61:39, v/v) on a Capcell Pack C18 MG II column (250 mm × 4.6 mm) at a flow rate of 1.0 mL/min and monitored at a detection wavelength of 220 nm. The calibration curve was linear within a plasma concentration range of 12.5-1,500 ng/mL, with a coefficient of determination of 0.9999. The intra- and inter-day coefficients of variation were 0.37-6.71% and 2.05-4.77%, respectively. The accuracy of the assay and recovery were 85.25-112.94% and > 86.58%, respectively. This proposed HPLC-UV method is simple and can be applied in clinical settings.</p>","PeriodicalId":47494,"journal":{"name":"Drug Discoveries and Therapeutics","volume":" ","pages":"260-264"},"PeriodicalIF":1.9000,"publicationDate":"2024-09-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Drug Discoveries and Therapeutics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5582/ddt.2024.01049","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/25 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0

Abstract

Anamorelin, a non-peptide ghrelin analog and growth hormone secretagogue, is a novel oral drug used to treat cancer cachexia. Patients with cancer cachexia frequently use several drugs and anamorelin is a substrate of cytochrome P450 (CYP) 3A4; therefore, drug-drug interactions with CYP3A4 inhibitors and inducers pose a clinical problem. In this study, we aimed to determine the concentration of anamorelin in human plasma using a simple high-performance liquid chromatography-ultraviolet (HPLC-UV)-based method. The analysis involved extracting a 200-μL plasma sample and protein precipitation using solid-phase extraction. Anamorelin was isocratically separated using a mobile phase consisting of 0.5% potassium dihydrogen phosphate (pH 4.5) and acetonitrile (61:39, v/v) on a Capcell Pack C18 MG II column (250 mm × 4.6 mm) at a flow rate of 1.0 mL/min and monitored at a detection wavelength of 220 nm. The calibration curve was linear within a plasma concentration range of 12.5-1,500 ng/mL, with a coefficient of determination of 0.9999. The intra- and inter-day coefficients of variation were 0.37-6.71% and 2.05-4.77%, respectively. The accuracy of the assay and recovery were 85.25-112.94% and > 86.58%, respectively. This proposed HPLC-UV method is simple and can be applied in clinical settings.

用简单的高效液相色谱-紫外检测法测定人体血浆中的阿那曲林浓度。
阿那莫林是一种非肽胃泌素类似物和生长激素分泌剂,是一种用于治疗癌症恶病质的新型口服药物。癌症恶病质患者经常使用多种药物,而阿那莫瑞林是细胞色素 P450 (CYP) 3A4 的底物,因此,与 CYP3A4 抑制剂和诱导剂的药物相互作用是一个临床问题。在本研究中,我们采用一种基于高效液相色谱-紫外(HPLC-UV)的简单方法测定了人血浆中阿那莫林的浓度。分析过程包括提取 200μL 的血浆样本,并使用固相萃取法沉淀蛋白质。采用 Capcell Pack C18 MG II 色谱柱(250 mm × 4.6 mm),以 0.5% 磷酸二氢钾(pH 4.5)和乙腈(61:39, v/v)为流动相进行等度分离,流速为 1.0 mL/min,检测波长为 220 nm。校准曲线在 12.5-1,500 纳克/毫升的血浆浓度范围内呈线性关系,测定系数为 0.9999。日内和日间变异系数分别为 0.37-6.71% 和 2.05-4.77%。测定准确度和回收率分别为 85.25-112.94% 和大于 86.58%。该高效液相色谱-紫外法操作简单,可应用于临床。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Drug Discoveries and Therapeutics
Drug Discoveries and Therapeutics PHARMACOLOGY & PHARMACY-
CiteScore
3.20
自引率
3.20%
发文量
51
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信