{"title":"Time-synchronized 2-deoxy-2-[18F]fluoro-D-glucose PET/MRI with MR-active trigger and Bayesian penalized likelihood reconstruction: Diagnostic utility for locoregional extension of endometrial cancer","authors":"","doi":"10.1016/j.ejrad.2024.111678","DOIUrl":null,"url":null,"abstract":"<div><h3>PURPOSE</h3><p>Minimal misregistration of fused PET and MRI images can be achieved with simultaneous positron emission tomography/magnetic resonance imaging (PET/MRI). However, the acquisition of multiple MRI sequences during a single PET emission scan may impair fusion precision of each sequence. This study evaluated the diagnostic utility of time-synchronized PET/MRI using an MR active trigger and a Bayesian penalized likelihood reconstruction algorithm (BPL) to assess the locoregional extension of endometrial cancer.</p></div><div><h3>METHODS</h3><p>Fifty-five patients with endometrial cancer who underwent pelvic 2-deoxy-2-[<sup>18</sup>F]fluoro-D-glucose PET/MRI were retrospectively evaluated. The PET emission time for the BPL reconstruction was determined by the MR active trigger of each MR sequence. The concordance rates of image interpretation with pathological T-staging, diagnostic performance for deep myometrial invasion (MI), and diagnostic confidence levels were evaluated by two readers and compared between time-synchronized, overlapping (conventional and simultaneous, but not time-synchronized), and sequential (not simultaneous) PET/MRI and MRI with diffusion-weighted imaging. Misregistration of the PET/MRI-fused images was determined by evaluating the differences in bladder dimensions.</p></div><div><h3>RESULTS</h3><p>The T classification by time-synchronized PET/MRI was the most concordant with the pathological T classification for the two readers. Time-synchronized PET/MRI had a significantly higher diagnostic performance for deep MI and higher confidence level scores than overlapping PET/MRI for the novice reader (<em>p</em> = 0.033 and <em>p</em> = 0.038, respectively). The differences in bladder dimension on sequential PET/MRI were significantly larger than those on overlapping and time-synchronized PET/MRI (<em>p</em> <0.001).</p></div><div><h3>CONCLUSION</h3><p>Time-synchronized PET/MRI is superior to conventional PET/MRI for assessing the locoregional extension of endometrial cancer.</p></div>","PeriodicalId":12063,"journal":{"name":"European Journal of Radiology","volume":null,"pages":null},"PeriodicalIF":3.2000,"publicationDate":"2024-08-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S0720048X24003942/pdfft?md5=776d58d9a486ed225646a1cf5d34fdc2&pid=1-s2.0-S0720048X24003942-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Radiology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0720048X24003942","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
Abstract
PURPOSE
Minimal misregistration of fused PET and MRI images can be achieved with simultaneous positron emission tomography/magnetic resonance imaging (PET/MRI). However, the acquisition of multiple MRI sequences during a single PET emission scan may impair fusion precision of each sequence. This study evaluated the diagnostic utility of time-synchronized PET/MRI using an MR active trigger and a Bayesian penalized likelihood reconstruction algorithm (BPL) to assess the locoregional extension of endometrial cancer.
METHODS
Fifty-five patients with endometrial cancer who underwent pelvic 2-deoxy-2-[18F]fluoro-D-glucose PET/MRI were retrospectively evaluated. The PET emission time for the BPL reconstruction was determined by the MR active trigger of each MR sequence. The concordance rates of image interpretation with pathological T-staging, diagnostic performance for deep myometrial invasion (MI), and diagnostic confidence levels were evaluated by two readers and compared between time-synchronized, overlapping (conventional and simultaneous, but not time-synchronized), and sequential (not simultaneous) PET/MRI and MRI with diffusion-weighted imaging. Misregistration of the PET/MRI-fused images was determined by evaluating the differences in bladder dimensions.
RESULTS
The T classification by time-synchronized PET/MRI was the most concordant with the pathological T classification for the two readers. Time-synchronized PET/MRI had a significantly higher diagnostic performance for deep MI and higher confidence level scores than overlapping PET/MRI for the novice reader (p = 0.033 and p = 0.038, respectively). The differences in bladder dimension on sequential PET/MRI were significantly larger than those on overlapping and time-synchronized PET/MRI (p <0.001).
CONCLUSION
Time-synchronized PET/MRI is superior to conventional PET/MRI for assessing the locoregional extension of endometrial cancer.