{"title":"Comparing visual and automated urine dipstick analysis in a general practice population.","authors":"S M L Cox, P Hoitinga, G J Oudhuis, R M Hopstaken, P H M Savelkoul, J W L Cals, E G P M de Bont","doi":"10.1080/02813432.2024.2392776","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Urinary symptoms constitute the primary reason for female patients to consult their general practitioner. The urinary dipstick test serves as a cornerstone for diagnosing urinary tract infections (UTIs), yet traditional visual interpretation may be subject to variability. Automated devices for dipstick urinalysis are routinely used as alternatives, yet the evidence regarding their accuracy remains limited. Therefore we aimed to compare concordance between visual and automated urinary dipstick interpretation and determine their test characteristics for the prediction of bacteriuria.</p><p><strong>Material and methods: </strong>We conducted a prospective validation study including urine samples originating from adult patients in general practice that were sent to the Maastricht Medical Centre + for urinary culture. Urinary dipstick tests were performed on each sample, which were interpreted visually and automatically. We calculated Cohen's κ and percentage agreement and used 2 × 2 tables to calculate test characteristics.</p><p><strong>Results: </strong>We included 302 urine samples. Visual and automated analysis showed almost perfect agreement (κ = 0.82 and κ = 0.86, respectively) for both nitrite and leukocyte esterase, but moderate agreement for erythrocytes (κ = 0.51). Interpretation of clinically relevant (nitrite and/or leukocyte esterase positive) samples showed almost perfect agreement (κ = 0.88). Urinary dipsticks show similar test characteristics with urinary culture as gold standard, with sensitivities of 0.92 and 0.91 and specificities of 0.37 and 0.41 for visual and automated interpretation respectively.</p><p><strong>Conclusion: </strong>Automated and visual dipstick analysis show near perfect agreement and perform similarly in predicting bacteriuria. However, automated analysis requires maintenance and occasionally measurement errors can occur.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-08-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/02813432.2024.2392776","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Urinary symptoms constitute the primary reason for female patients to consult their general practitioner. The urinary dipstick test serves as a cornerstone for diagnosing urinary tract infections (UTIs), yet traditional visual interpretation may be subject to variability. Automated devices for dipstick urinalysis are routinely used as alternatives, yet the evidence regarding their accuracy remains limited. Therefore we aimed to compare concordance between visual and automated urinary dipstick interpretation and determine their test characteristics for the prediction of bacteriuria.

Material and methods: We conducted a prospective validation study including urine samples originating from adult patients in general practice that were sent to the Maastricht Medical Centre + for urinary culture. Urinary dipstick tests were performed on each sample, which were interpreted visually and automatically. We calculated Cohen's κ and percentage agreement and used 2 × 2 tables to calculate test characteristics.

Results: We included 302 urine samples. Visual and automated analysis showed almost perfect agreement (κ = 0.82 and κ = 0.86, respectively) for both nitrite and leukocyte esterase, but moderate agreement for erythrocytes (κ = 0.51). Interpretation of clinically relevant (nitrite and/or leukocyte esterase positive) samples showed almost perfect agreement (κ = 0.88). Urinary dipsticks show similar test characteristics with urinary culture as gold standard, with sensitivities of 0.92 and 0.91 and specificities of 0.37 and 0.41 for visual and automated interpretation respectively.

Conclusion: Automated and visual dipstick analysis show near perfect agreement and perform similarly in predicting bacteriuria. However, automated analysis requires maintenance and occasionally measurement errors can occur.

在全科医生群体中比较目测和自动尿液浸量计分析。
导言:泌尿系统症状是女性患者向全科医生咨询的主要原因。尿液浸量棒测试是诊断尿路感染(UTI)的基石,但传统的目测判读可能会出现偏差。尿液浸量棒检测的自动设备已成为常规替代方法,但有关其准确性的证据仍然有限。因此,我们的目的是比较目测和自动尿液测厚仪判读的一致性,并确定它们在预测细菌尿方面的测试特性:我们进行了一项前瞻性验证研究,研究对象包括全科成年患者的尿液样本,这些样本被送往马斯特里赫特医疗中心 + 进行尿液培养。对每份样本都进行了尿液量尺检测,并通过肉眼自动判读。我们计算了 Cohen's κ 和一致性百分比,并使用 2 × 2 表计算检验特征:我们共采集了 302 份尿样。目测和自动分析结果显示,亚硝酸盐和白细胞酯酶的检测结果几乎完全一致(分别为κ = 0.82和κ = 0.86),但红细胞的检测结果一致性一般(κ = 0.51)。对临床相关(亚硝酸盐和/或白细胞酯酶阳性)样本的解释几乎完全一致(κ = 0.88)。以尿培养为金标准的尿液量尺显示出相似的检测特性,目测和自动判读的灵敏度分别为 0.92 和 0.91,特异性分别为 0.37 和 0.41:结论:自动分析和目测量杯分析在预测菌尿方面显示出近乎完美的一致性和相似的表现。然而,自动分析需要维护,偶尔会出现测量误差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Accounts of Chemical Research
Accounts of Chemical Research 化学-化学综合
CiteScore
31.40
自引率
1.10%
发文量
312
审稿时长
2 months
期刊介绍: Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance. Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信