Non-invasive technology to assess hydration status in advanced cancer to explore relationships between fluid status and symptoms: an observational study using bioelectrical impedance analysis.

IF 2.5 2区 医学 Q2 HEALTH CARE SCIENCES & SERVICES
Amara Callistus Nwosu, Sarah Stanley, Catriona R Mayland, Stephen Mason, Alexandra McDougall, John E Ellershaw
{"title":"Non-invasive technology to assess hydration status in advanced cancer to explore relationships between fluid status and symptoms: an observational study using bioelectrical impedance analysis.","authors":"Amara Callistus Nwosu, Sarah Stanley, Catriona R Mayland, Stephen Mason, Alexandra McDougall, John E Ellershaw","doi":"10.1186/s12904-024-01542-z","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Oral fluid intake decreases in advanced cancer in the dying phase of illness. There is inadequate evidence to support the assessment, and management, of hydration in the dying. Bioelectrical impedance analysis (BIA) is a body composition assessment tool. BIA has the potential to inform clinal management in advanced cancer, by examining the relationships between hydration status and clinical variables.</p><p><strong>Aim: </strong>BIA was used to determine the association between hydration status, symptoms, clinical signs, quality-of-life and survival in advanced cancer, including those who are dying (i.e. in the last week of life).</p><p><strong>Materials and methods: </strong>We conducted a prospective observational study of people with advanced cancer in three centres. Advance consent methodology was used to conduct hydration assessments in the dying. Total body water was estimated using the BIA Impedance index (Height - H (m)<sup>2</sup> /Resistance - R (Ohms)). Backward regression was used to identify factors (physical signs, symptoms, quality of life) that predicted H<sup>2</sup>/R. Participants in the last 7 days of life were further assessed with BIA to assess hydration changes, and its relationship with clinical outcomes.</p><p><strong>Results: </strong>One hundred and twenty-five people participated (males n = 74 (59.2%), females, n = 51 (40.8%)). We used backward regression analysis to describe a statistical model to predict hydration status in advanced cancer. The model demonstrated that 'less hydration' (lower H<sup>2</sup>/R) was associated with female sex (Beta = -0.39, p < 0.001), increased appetite (Beta = -0.12, p = 0.09), increased dehydration assessment scale score (dry mouth, dry axilla, sunken eyes - Beta = -0.19, p = 0.006), and increased breathlessness (Beta = -0.15, p = 0.03). 'More hydration' (higher H<sup>2</sup>/R) was associated with oedema (Beta = 0.49, p < 0.001). In dying participants (n = 18, 14.4%), hydration status (H<sup>2</sup>/R) was not significantly different compared to their baseline measurements (n = 18, M = 49.6, SD = 16.0 vs. M = 51.0, SD = 12.1; t(17) = 0.64, p = 0.53) and was not significantly associated with agitation (r<sub>s</sub> = -0.85, p = 0.74), pain (r<sub>s</sub> = 0.31, p = 0.23) or respiratory tract secretions (r<sub>s</sub> = -0.34, p = 0.19).</p><p><strong>Conclusions: </strong>This is the first study to use bioimpedance to report a model (using clinical factors) to predict hydration status in advanced cancer. Our data demonstrates the feasibility of using an advance consent method to conduct research in dying people. This method can potentially improve the evidence base (and hence, quality of care) for the dying. Future BIA research can involve hydration assessment of cancers (according to type and stage) and associated variables (e.g., stage of illness, ethnicity and gender). Further work can use BIA to identify clinically relevant outcomes for hydration studies and establish a core outcome set to evaluate how hydration affects symptoms and quality-of-life in cancer.</p>","PeriodicalId":48945,"journal":{"name":"BMC Palliative Care","volume":"23 1","pages":"209"},"PeriodicalIF":2.5000,"publicationDate":"2024-08-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11331739/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Palliative Care","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12904-024-01542-z","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"HEALTH CARE SCIENCES & SERVICES","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Oral fluid intake decreases in advanced cancer in the dying phase of illness. There is inadequate evidence to support the assessment, and management, of hydration in the dying. Bioelectrical impedance analysis (BIA) is a body composition assessment tool. BIA has the potential to inform clinal management in advanced cancer, by examining the relationships between hydration status and clinical variables.

Aim: BIA was used to determine the association between hydration status, symptoms, clinical signs, quality-of-life and survival in advanced cancer, including those who are dying (i.e. in the last week of life).

Materials and methods: We conducted a prospective observational study of people with advanced cancer in three centres. Advance consent methodology was used to conduct hydration assessments in the dying. Total body water was estimated using the BIA Impedance index (Height - H (m)2 /Resistance - R (Ohms)). Backward regression was used to identify factors (physical signs, symptoms, quality of life) that predicted H2/R. Participants in the last 7 days of life were further assessed with BIA to assess hydration changes, and its relationship with clinical outcomes.

Results: One hundred and twenty-five people participated (males n = 74 (59.2%), females, n = 51 (40.8%)). We used backward regression analysis to describe a statistical model to predict hydration status in advanced cancer. The model demonstrated that 'less hydration' (lower H2/R) was associated with female sex (Beta = -0.39, p < 0.001), increased appetite (Beta = -0.12, p = 0.09), increased dehydration assessment scale score (dry mouth, dry axilla, sunken eyes - Beta = -0.19, p = 0.006), and increased breathlessness (Beta = -0.15, p = 0.03). 'More hydration' (higher H2/R) was associated with oedema (Beta = 0.49, p < 0.001). In dying participants (n = 18, 14.4%), hydration status (H2/R) was not significantly different compared to their baseline measurements (n = 18, M = 49.6, SD = 16.0 vs. M = 51.0, SD = 12.1; t(17) = 0.64, p = 0.53) and was not significantly associated with agitation (rs = -0.85, p = 0.74), pain (rs = 0.31, p = 0.23) or respiratory tract secretions (rs = -0.34, p = 0.19).

Conclusions: This is the first study to use bioimpedance to report a model (using clinical factors) to predict hydration status in advanced cancer. Our data demonstrates the feasibility of using an advance consent method to conduct research in dying people. This method can potentially improve the evidence base (and hence, quality of care) for the dying. Future BIA research can involve hydration assessment of cancers (according to type and stage) and associated variables (e.g., stage of illness, ethnicity and gender). Further work can use BIA to identify clinically relevant outcomes for hydration studies and establish a core outcome set to evaluate how hydration affects symptoms and quality-of-life in cancer.

采用无创技术评估晚期癌症患者的水合状态,以探索体液状态与症状之间的关系:一项使用生物电阻抗分析的观察性研究。
背景:晚期癌症患者在病危阶段的口服液摄入量会减少。目前还没有足够的证据支持对临终患者进行水合评估和管理。生物电阻抗分析 (BIA) 是一种身体成分评估工具。目的: 使用生物电阻抗分析确定晚期癌症患者(包括生命垂危者(即生命的最后一周))的水合状态、症状、临床体征、生活质量和存活率之间的关系:我们在三个中心对晚期癌症患者进行了前瞻性观察研究。采用事先征得同意的方法对临终患者进行水合评估。使用 BIA 阻抗指数(高度 - H (m)2 / 电阻 - R (欧姆))估算体内总水分。采用后向回归法确定预测 H2/R 的因素(体征、症状、生活质量)。通过 BIA 对生命最后 7 天的参与者进行进一步评估,以评估水合变化及其与临床结果的关系:125 名参与者(男性 n = 74(59.2%),女性 n = 51(40.8%))。我们使用反向回归分析法描述了一个预测晚期癌症患者水合状态的统计模型。该模型表明,"较少水合"(较低 H2/R)与女性性别相关(Beta = -0.39,p 2/R),与水肿相关(Beta = 0.49,p 2/R),但与基线测量值相比无显著差异(n = 18,M = 49.6, SD = 16.0 vs. M = 51.0, SD = 12.1; t(17) = 0.64, p = 0.53),并且与躁动(rs = -0.85, p = 0.74)、疼痛(rs = 0.31, p = 0.23)或呼吸道分泌物(rs = -0.34, p = 0.19)无明显关联:这是第一项使用生物阻抗报告晚期癌症患者水合状态预测模型(使用临床因素)的研究。我们的数据证明了使用预先同意的方法对临终者进行研究的可行性。这种方法有可能改善临终者的证据基础(从而提高护理质量)。未来的 BIA 研究可以涉及癌症(根据类型和阶段)和相关变量(如疾病阶段、种族和性别)的水合评估。进一步的工作可以使用 BIA 确定水合研究的临床相关结果,并建立一套核心结果来评估水合如何影响癌症患者的症状和生活质量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
BMC Palliative Care
BMC Palliative Care HEALTH CARE SCIENCES & SERVICES-
CiteScore
4.60
自引率
9.70%
发文量
201
审稿时长
21 weeks
期刊介绍: BMC Palliative Care is an open access journal publishing original peer-reviewed research articles in the clinical, scientific, ethical and policy issues, local and international, regarding all aspects of hospice and palliative care for the dying and for those with profound suffering related to chronic illness.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信