Joshua P Metlay, Ralph Gonzales, Timothy J Judson, Yuchiao Chang, Justin Margolin, Samir Oza, Blair A Parry, Michelle D Tagerman, Emily Hayden
{"title":"Accuracy of Patient-Collected Vital Signs.","authors":"Joshua P Metlay, Ralph Gonzales, Timothy J Judson, Yuchiao Chang, Justin Margolin, Samir Oza, Blair A Parry, Michelle D Tagerman, Emily Hayden","doi":"10.1089/tmj.2023.0548","DOIUrl":null,"url":null,"abstract":"<p><p><b>Introduction:</b> Telehealth has emerged as an important clinical setting for managing acute respiratory tract infections (ARIs), potentially reducing emergency department and urgent care overcrowding, and reducing nosocomial transmission. Many current algorithms for ARI management incorporate information on patient vital signs. However, the accuracy of vital signs collected by patients using readily available home devices and techniques has not been studied. <b>Methods:</b> A cross-sectional sample of patients seen for urgent conditions at a hospital emergency and urgent care center were given instructions and low-cost, readily available devices to collect their vital signs. A trained research coordinator collected a parallel set of vital signs using standard hospital equipment, serving as the gold standard. We analyzed the performance of patient-collected vital signs compared with vital signs collected by a trained research coordinator. <b>Results:</b> A total of 300 patients completed the study. Patient-collected vital signs were highly specific for traditional levels of abnormalities (HR >100 beats per min, RR >24 breaths per min, temperature >100.4 degrees Fahrenheit, oxygen saturation <94 percent); however, sensitivity was poor for elevated heart rate by pulse estimation (25%) and elevated respiratory rate (60%). Heart rate and oxygen saturation by pulse oximeter and oral temperature had higher sensitivity. <b>Conclusions:</b> Vital signs measured and provided by patients are not uniformly accurate, particularly when using manual techniques rather than automated devices. Telehealth algorithms that rely on these values could provide incorrect triage and management advice.</p>","PeriodicalId":54434,"journal":{"name":"Telemedicine and e-Health","volume":" ","pages":"2747-2751"},"PeriodicalIF":2.8000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Telemedicine and e-Health","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1089/tmj.2023.0548","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/8/16 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"HEALTH CARE SCIENCES & SERVICES","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: Telehealth has emerged as an important clinical setting for managing acute respiratory tract infections (ARIs), potentially reducing emergency department and urgent care overcrowding, and reducing nosocomial transmission. Many current algorithms for ARI management incorporate information on patient vital signs. However, the accuracy of vital signs collected by patients using readily available home devices and techniques has not been studied. Methods: A cross-sectional sample of patients seen for urgent conditions at a hospital emergency and urgent care center were given instructions and low-cost, readily available devices to collect their vital signs. A trained research coordinator collected a parallel set of vital signs using standard hospital equipment, serving as the gold standard. We analyzed the performance of patient-collected vital signs compared with vital signs collected by a trained research coordinator. Results: A total of 300 patients completed the study. Patient-collected vital signs were highly specific for traditional levels of abnormalities (HR >100 beats per min, RR >24 breaths per min, temperature >100.4 degrees Fahrenheit, oxygen saturation <94 percent); however, sensitivity was poor for elevated heart rate by pulse estimation (25%) and elevated respiratory rate (60%). Heart rate and oxygen saturation by pulse oximeter and oral temperature had higher sensitivity. Conclusions: Vital signs measured and provided by patients are not uniformly accurate, particularly when using manual techniques rather than automated devices. Telehealth algorithms that rely on these values could provide incorrect triage and management advice.
期刊介绍:
Telemedicine and e-Health is the leading peer-reviewed journal for cutting-edge telemedicine applications for achieving optimal patient care and outcomes. It places special emphasis on the impact of telemedicine on the quality, cost effectiveness, and access to healthcare. Telemedicine applications play an increasingly important role in health care. They offer indispensable tools for home healthcare, remote patient monitoring, and disease management, not only for rural health and battlefield care, but also for nursing home, assisted living facilities, and maritime and aviation settings.
Telemedicine and e-Health offers timely coverage of the advances in technology that offer practitioners, medical centers, and hospitals new and innovative options for managing patient care, electronic records, and medical billing.