Comparison of coating stability and surface characterization of different esthetic NiTi arch wires – An in vivo study

IF 0.5 Q4 DENTISTRY, ORAL SURGERY & MEDICINE
Syed Shahid Hilal, P. Teja, S. Mittal, S. Teja, Stuti Gulati, Rohini Sharma
{"title":"Comparison of coating stability and surface characterization of different esthetic NiTi arch wires – An in vivo study","authors":"Syed Shahid Hilal, P. Teja, S. Mittal, S. Teja, Stuti Gulati, Rohini Sharma","doi":"10.25259/apos_75_2024","DOIUrl":null,"url":null,"abstract":"\n\nThe article aimed to compare the coating stability and surface characterization of different esthetic nickel-titanium (NiTi) archwires.\n\n\n\nA total of 48 esthetic NiTi archwires were categorized into four groups based on the type of coating material that was selected and studied (Groups: I. Epoxy coated, II. Polymer coated, III. Teflon coated, and IV. Rhodium coated). These wires were ligated in patients undergoing fixed mechanotherapy in the department. The surface details and coating stability were studied in the wires removed from patient’s mouth after 21 days using 3D profilometer, scanning electron microscope (SEM), and stereomicroscope.\n\n\n\nA maximum percentage of coating loss was observed in Group II (epoxy coated) and the minimum in Group III (polymer coated). Maximum surface roughness was observed in Group II (epoxy coated) and minimum in Group III (polymer coated).\n\n\n\nThe average coating thickness of as received wires was observed to be 0.002” in dimension. All the wires had low esthetic values, as they presented a non-durable coating after oral exposure. On visual examination of SEM image, all four group esthetic wires showed variations ranging from microcracks and large sized striations to overall destruction of coating regularity.\n","PeriodicalId":42593,"journal":{"name":"APOS Trends in Orthodontics","volume":null,"pages":null},"PeriodicalIF":0.5000,"publicationDate":"2024-08-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"APOS Trends in Orthodontics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25259/apos_75_2024","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

The article aimed to compare the coating stability and surface characterization of different esthetic nickel-titanium (NiTi) archwires. A total of 48 esthetic NiTi archwires were categorized into four groups based on the type of coating material that was selected and studied (Groups: I. Epoxy coated, II. Polymer coated, III. Teflon coated, and IV. Rhodium coated). These wires were ligated in patients undergoing fixed mechanotherapy in the department. The surface details and coating stability were studied in the wires removed from patient’s mouth after 21 days using 3D profilometer, scanning electron microscope (SEM), and stereomicroscope. A maximum percentage of coating loss was observed in Group II (epoxy coated) and the minimum in Group III (polymer coated). Maximum surface roughness was observed in Group II (epoxy coated) and minimum in Group III (polymer coated). The average coating thickness of as received wires was observed to be 0.002” in dimension. All the wires had low esthetic values, as they presented a non-durable coating after oral exposure. On visual examination of SEM image, all four group esthetic wires showed variations ranging from microcracks and large sized striations to overall destruction of coating regularity.
不同美学镍钛弓丝涂层稳定性和表面特征的比较 - 体内研究
文章旨在比较不同美学镍钛(NiTi)弓丝的涂层稳定性和表面特征。根据所选涂层材料的类型和研究内容,将总共 48 件美学镍钛弓丝分为四组(组别:I. 环氧树脂涂层;II:I. 环氧树脂涂层,II.聚合物涂层,III.聚四氟乙烯涂层,以及 IV.铑涂层)。这些钢丝是在该科接受固定机械疗法的患者身上结扎的。使用三维轮廓仪、扫描电子显微镜(SEM)和体视显微镜研究了 21 天后从患者口中取出的钢丝的表面细节和涂层稳定性。第二组(环氧树脂涂层)的表面粗糙度最大,第三组(聚合物涂层)的表面粗糙度最小。所有钢丝的美学价值都很低,因为它们在口腔暴露后呈现出不耐久的涂层。通过扫描电子显微镜(SEM)图像的目视检查,所有四组美观钢丝都出现了不同程度的变化,有的出现微裂纹和大尺寸条纹,有的则整体破坏了涂层的规则性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
APOS Trends in Orthodontics
APOS Trends in Orthodontics DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
0.80
自引率
0.00%
发文量
47
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信