{"title":"Feasibility and Accuracy of Ultrasound-Guided Core Needle Biopsy for Nipple Lesions: A Pilot Study.","authors":"Sophia R O'Brien, Damien Medrano, Julia Birnbaum, Elizabeth S McDonald, Emily F Conant, Susan P Weinstein, Oluwadamilola M Fayanju, Samantha P Zuckerman, Christine E Edmonds","doi":"10.1093/jbi/wbae033","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Due to the superficial location, suspicious findings of the nipple-areolar complex (NAC) are not amenable to stereotactic or MRI-guided sampling and have historically necessitated surgical biopsy or skin-punch biopsy. There are limited reports of US-guided core biopsy of the nipple (US-CBN).</p><p><strong>Objective: </strong>We report our nearly 3-year pilot experience with US-CBN at an academic breast imaging center.</p><p><strong>Methods: </strong>An institutional review board-exempt and HIPAA-compliant retrospective review was performed. We assessed patient demographics, breast imaging characteristics, procedural data, pathology, and outcomes.</p><p><strong>Results: </strong>Nine female patients aged 27 to 64 underwent US-CBN from January 2021 to October 2023. Initial imaging abnormalities included abnormal MRI enhancement, mammographic calcifications, and sonographic masses. After initial or second-look US, all imaging findings had sonographic correlates for biopsy specimens, the majority of which were sonographic masses (8/9). US-CBN was performed by 6 breast radiologists using a variety of devices. All biopsy specimen results were concordant with sonographic abnormalities, although 1 was considered discordant from the initial abnormality seen on MRI. There were no complications, and discomfort during the procedure was well-treated. Two patients (22%, 2/9) were diagnosed with malignancy.</p><p><strong>Conclusion: </strong>This pilot study demonstrated that US-CBN can be performed by a breast radiologist for definitive diagnosis of suspicious nipple abnormalities seen on breast imaging, avoiding surgery, and maintaining nipple integrity. In our population, 22% (2/9) of US-CBNs revealed malignancy.</p>","PeriodicalId":43134,"journal":{"name":"Journal of Breast Imaging","volume":null,"pages":null},"PeriodicalIF":2.0000,"publicationDate":"2024-09-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Breast Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1093/jbi/wbae033","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Background: Due to the superficial location, suspicious findings of the nipple-areolar complex (NAC) are not amenable to stereotactic or MRI-guided sampling and have historically necessitated surgical biopsy or skin-punch biopsy. There are limited reports of US-guided core biopsy of the nipple (US-CBN).
Objective: We report our nearly 3-year pilot experience with US-CBN at an academic breast imaging center.
Methods: An institutional review board-exempt and HIPAA-compliant retrospective review was performed. We assessed patient demographics, breast imaging characteristics, procedural data, pathology, and outcomes.
Results: Nine female patients aged 27 to 64 underwent US-CBN from January 2021 to October 2023. Initial imaging abnormalities included abnormal MRI enhancement, mammographic calcifications, and sonographic masses. After initial or second-look US, all imaging findings had sonographic correlates for biopsy specimens, the majority of which were sonographic masses (8/9). US-CBN was performed by 6 breast radiologists using a variety of devices. All biopsy specimen results were concordant with sonographic abnormalities, although 1 was considered discordant from the initial abnormality seen on MRI. There were no complications, and discomfort during the procedure was well-treated. Two patients (22%, 2/9) were diagnosed with malignancy.
Conclusion: This pilot study demonstrated that US-CBN can be performed by a breast radiologist for definitive diagnosis of suspicious nipple abnormalities seen on breast imaging, avoiding surgery, and maintaining nipple integrity. In our population, 22% (2/9) of US-CBNs revealed malignancy.