A New Convenient Method to Assess Antibiotic Resistance and Antimicrobial Efficacy against Pathogenic Clostridioides difficile Biofilms

Lingjun Xu, Bijay Gurung, Chris Gu, Shaohua Wang, Tingyue Gu
{"title":"A New Convenient Method to Assess Antibiotic Resistance and Antimicrobial Efficacy against Pathogenic Clostridioides difficile Biofilms","authors":"Lingjun Xu, Bijay Gurung, Chris Gu, Shaohua Wang, Tingyue Gu","doi":"10.3390/antibiotics13080728","DOIUrl":null,"url":null,"abstract":"Clostridioides difficile is a widely distributed anaerobic pathogen. C. difficile infection is a serious problem in healthcare. Its biofilms have been found to exhibit biocorrosivity, albeit very little, but sufficient for it to correlate with biofilm growth/health. This work demonstrated the use of a disposable electrochemical biofilm test kit using two solid-state electrodes (a 304 stainless steel working electrode, and a graphite counter electrode, which also served as the reference electrode) in a 10 mL serum vial. It was found that the C. difficile 630∆erm Adp-4 mutant had a minimum inhibitory concentration (MIC) for vancomycin twice that of the 630∆erm wild type strain in biofilm prevention (2 ppm vs. 1 ppm by mass) on 304 stainless steel. Glutaraldehyde, a commonly used hospital disinfectant, was found ineffective at 2% (w/w) for the prevention of C. difficile 630∆erm wild type biofilm formation, while tetrakis(hydroxymethyl)phosphonium sulfate (THPS) disinfectant was very effective at 100 ppm for both biofilm prevention and biofilm killing. These antimicrobial efficacy data were consistent with sessile cell count and biofilm imaging results. Furthermore, the test kit provided additional transient biocide treatment information. It showed that vancomycin killed C. difficile 630∆erm wild type biofilms in 2 d, while THPS only required minutes.","PeriodicalId":8151,"journal":{"name":"Antibiotics","volume":"56 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-08-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Antibiotics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/antibiotics13080728","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Clostridioides difficile is a widely distributed anaerobic pathogen. C. difficile infection is a serious problem in healthcare. Its biofilms have been found to exhibit biocorrosivity, albeit very little, but sufficient for it to correlate with biofilm growth/health. This work demonstrated the use of a disposable electrochemical biofilm test kit using two solid-state electrodes (a 304 stainless steel working electrode, and a graphite counter electrode, which also served as the reference electrode) in a 10 mL serum vial. It was found that the C. difficile 630∆erm Adp-4 mutant had a minimum inhibitory concentration (MIC) for vancomycin twice that of the 630∆erm wild type strain in biofilm prevention (2 ppm vs. 1 ppm by mass) on 304 stainless steel. Glutaraldehyde, a commonly used hospital disinfectant, was found ineffective at 2% (w/w) for the prevention of C. difficile 630∆erm wild type biofilm formation, while tetrakis(hydroxymethyl)phosphonium sulfate (THPS) disinfectant was very effective at 100 ppm for both biofilm prevention and biofilm killing. These antimicrobial efficacy data were consistent with sessile cell count and biofilm imaging results. Furthermore, the test kit provided additional transient biocide treatment information. It showed that vancomycin killed C. difficile 630∆erm wild type biofilms in 2 d, while THPS only required minutes.
评估抗生素耐药性和抗生素对致病性艰难梭菌生物膜疗效的便捷新方法
艰难梭菌是一种广泛分布的厌氧病原体。艰难梭菌感染是医疗保健领域的一个严重问题。研究发现,其生物膜具有生物腐蚀性,尽管很小,但足以与生物膜的生长/健康状况相关联。这项工作展示了在 10 毫升血清瓶中使用一次性电化学生物膜检测试剂盒,该试剂盒使用两个固态电极(一个 304 不锈钢工作电极和一个石墨对电极,后者也可用作参比电极)。结果发现,在 304 不锈钢上,艰难梭菌 630∆erm Adp-4 突变体对万古霉素的最低抑制浓度(MIC)是 630∆erm 野生型菌株在生物膜预防方面的两倍(按质量计算为 2 ppm 对 1 ppm)。医院常用的消毒剂戊二醛在 2%(w/w)浓度下对预防艰难梭菌 630∆erm 野生型生物膜形成无效,而四羟甲基硫酸磷(THPS)消毒剂在 100 ppm 浓度下对预防生物膜形成和杀灭生物膜都非常有效。这些抗菌效果数据与无柄细胞计数和生物膜成像结果一致。此外,测试套件还提供了更多瞬时杀菌剂处理信息。它显示万古霉素能在 2 天内杀死艰难梭菌 630 Δerm 野生型生物膜,而 THPS 只需要几分钟。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信