Five-year migration of uncemented femoral components in total knee arthroplasty with either highly cross-linked or conventional polyethylene inserts: a blinded randomized controlled trial using radiostereometric analysis.

IF 4.9 1区 医学 Q1 ORTHOPEDICS
Ruud de Ridder, Bart L Kaptein, Bart G Pijls, Rob G H H Nelissen, Herman H Kaptijn
{"title":"Five-year migration of uncemented femoral components in total knee arthroplasty with either highly cross-linked or conventional polyethylene inserts: a blinded randomized controlled trial using radiostereometric analysis.","authors":"Ruud de Ridder, Bart L Kaptein, Bart G Pijls, Rob G H H Nelissen, Herman H Kaptijn","doi":"10.1302/0301-620X.106B8.BJJ-2023-1429.R1","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>The aim of this study was to compare the migration of the femoral component, five years postoperatively, between patients with a highly cross-linked polyethylene (HXLPE) insert and those with a conventional polyethylene (PE) insert in an uncemented Triathlon fixed insert cruciate-retaining total knee arthroplasty (TKA). Secondary aims included clinical outcomes and patient-reported outcome measures (PROMs). We have previously reported the migration and outcome of the tibial components in these patients.</p><p><strong>Methods: </strong>A double-blinded randomized controlled trial was conducted including 96 TKAs. The migration of the femoral component was measured with radiostereometry (RSA) at three and six months and one, two, and five years postoperatively. PROMs were collected preoperatively and at all periods of follow-up.</p><p><strong>Results: </strong>There was no clinically relevant difference in terms of migration of the femoral component or PROMs between the HXLPE and PE groups. The mean difference in migration (maximum total point motion), five years postopeatively, was 0.04 mm (95% CI -0.06 to 0.16) in favour of the PE group.</p><p><strong>Conclusion: </strong>There was no clinically relevant difference in migration of the femoral component, for up to five years between the two groups. These findings will help to establish a benchmark for future studies on migration of femoral components in TKA.</p>","PeriodicalId":48944,"journal":{"name":"Bone & Joint Journal","volume":"106-B 8","pages":"826-833"},"PeriodicalIF":4.9000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bone & Joint Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1302/0301-620X.106B8.BJJ-2023-1429.R1","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
引用次数: 0

Abstract

Aims: The aim of this study was to compare the migration of the femoral component, five years postoperatively, between patients with a highly cross-linked polyethylene (HXLPE) insert and those with a conventional polyethylene (PE) insert in an uncemented Triathlon fixed insert cruciate-retaining total knee arthroplasty (TKA). Secondary aims included clinical outcomes and patient-reported outcome measures (PROMs). We have previously reported the migration and outcome of the tibial components in these patients.

Methods: A double-blinded randomized controlled trial was conducted including 96 TKAs. The migration of the femoral component was measured with radiostereometry (RSA) at three and six months and one, two, and five years postoperatively. PROMs were collected preoperatively and at all periods of follow-up.

Results: There was no clinically relevant difference in terms of migration of the femoral component or PROMs between the HXLPE and PE groups. The mean difference in migration (maximum total point motion), five years postopeatively, was 0.04 mm (95% CI -0.06 to 0.16) in favour of the PE group.

Conclusion: There was no clinically relevant difference in migration of the femoral component, for up to five years between the two groups. These findings will help to establish a benchmark for future studies on migration of femoral components in TKA.

全膝关节置换术中使用高交联或传统聚乙烯插入物的非骨水泥股骨组件的五年迁移:使用放射线立体计量分析的盲法随机对照试验。
目的:本研究旨在比较在非骨水泥Triathlon固定插入式十字固位全膝关节置换术(TKA)中使用高交联聚乙烯(HXLPE)插入物和使用传统聚乙烯(PE)插入物的患者在术后五年股骨组件的移位情况。次要目的包括临床结果和患者报告的结果测量(PROMs)。我们以前曾报道过这些患者胫骨组件的移位和结果:我们进行了一项双盲随机对照试验,包括 96 例 TKA。在术后三个月、六个月以及一年、两年和五年时,采用放射性立体测量法(RSA)测量股骨组件的移位情况。术前和所有随访期间均收集了PROM:结果:HXLPE组和PE组在股骨组件移位或PROM方面没有临床相关性差异。PE组术后五年的移位(最大总点运动)平均差异为0.04毫米(95% CI -0.06至0.16):结论:两组患者的股骨组件在五年内的移位没有临床相关性差异。这些发现将有助于为今后有关 TKA 中股骨组件移位的研究建立一个基准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Bone & Joint Journal
Bone & Joint Journal ORTHOPEDICS-SURGERY
CiteScore
9.40
自引率
10.90%
发文量
318
期刊介绍: We welcome original articles from any part of the world. The papers are assessed by members of the Editorial Board and our international panel of expert reviewers, then either accepted for publication or rejected by the Editor. We receive over 2000 submissions each year and accept about 250 for publication, many after revisions recommended by the reviewers, editors or statistical advisers. A decision usually takes between six and eight weeks. Each paper is assessed by two reviewers with a special interest in the subject covered by the paper, and also by members of the editorial team. Controversial papers will be discussed at a full meeting of the Editorial Board. Publication is between four and six months after acceptance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信