{"title":"Dosiomics-based detection of dose distribution variations in helical tomotherapy for prostate cancer patients: influence of treatment plan parameters.","authors":"Marziyeh Mirzaeiyan, Ali Akhavan, Simin Hemati, Mahnaz Etehadtavakol, Alireza Amouheidari, Atoosa Adibi, Hossein Khanahmad, Zahra Sharifonnasabi, Parvaneh Shokrani","doi":"10.1007/s13246-024-01463-4","DOIUrl":null,"url":null,"abstract":"<p><p>The stability of dosiomics features (DFs) and dose-volume histogram (DVH) parameters for detecting disparities in helical tomotherapy planned dose distributions was assessed. Treatment plans of 18 prostate patients were recalculated using the followings: field width (WF) (2.5 vs. 5), pitch factor (PF) (0.433 vs. 0.444), and modulation factor (MF) (2.5 vs. 3). From each of the eight plans per patient, ninety-three original and 744 wavelet-based DFs were extracted, using 3D-Slicer software, across six regions including: target volume (PTV), pelvic lymph nodes (PTV-LN), PTV + PTV-LN (PTV-All), one cm rind around PTV-All (PTV-Ring), rectum, and bladder. For the resulting DFs and DVH parameters, the coefficient of variation (CV) was calculated, and using hierarchical clustering, the features were classified into low/high variability. The significance of parameters on instability was analyzed by a three-way analysis of variance. All DF's were stable in PTV, PTV-LN, and PTV-Ring (average CV ( <math> <mrow> <mover><mrow><mi>CV</mi></mrow> <mo>¯</mo></mover> <mrow><mo>)</mo></mrow> </mrow> </math> ≤ 0.36). Only one feature in the bladder ( <math> <mover><mrow><mi>CV</mi></mrow> <mo>¯</mo></mover> </math> = 0.9), rectum ( <math> <mover><mrow><mi>CV</mi></mrow> <mo>¯</mo></mover> </math> = 0.4), and PTV-All ( <math> <mover><mrow><mi>CV</mi></mrow> <mo>¯</mo></mover> </math> = 0.37) were considered unstable due to change in MF in the bladder and WF in the PTV-All. The value of <math> <mover><mrow><mi>CV</mi></mrow> <mo>¯</mo></mover> </math> for the wavelet features was much higher than that for the original features. Out of 225 unstable wavelet features, 84 features had <math> <mover><mrow><mi>CV</mi></mrow> <mo>¯</mo></mover> </math> ≥ 1. The CVs for all the DVHs remained very small ( <math> <mover><mrow><mi>CV</mi></mrow> <mo>¯</mo></mover> </math> < 0.06). This study highlights that the sensitivity of DFs to changes in tomotherapy planning parameters is influenced by the region and the DFs, particularly wavelet features, surpassing the effectiveness of DVHs.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-07-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s13246-024-01463-4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0
Abstract
The stability of dosiomics features (DFs) and dose-volume histogram (DVH) parameters for detecting disparities in helical tomotherapy planned dose distributions was assessed. Treatment plans of 18 prostate patients were recalculated using the followings: field width (WF) (2.5 vs. 5), pitch factor (PF) (0.433 vs. 0.444), and modulation factor (MF) (2.5 vs. 3). From each of the eight plans per patient, ninety-three original and 744 wavelet-based DFs were extracted, using 3D-Slicer software, across six regions including: target volume (PTV), pelvic lymph nodes (PTV-LN), PTV + PTV-LN (PTV-All), one cm rind around PTV-All (PTV-Ring), rectum, and bladder. For the resulting DFs and DVH parameters, the coefficient of variation (CV) was calculated, and using hierarchical clustering, the features were classified into low/high variability. The significance of parameters on instability was analyzed by a three-way analysis of variance. All DF's were stable in PTV, PTV-LN, and PTV-Ring (average CV ( ≤ 0.36). Only one feature in the bladder ( = 0.9), rectum ( = 0.4), and PTV-All ( = 0.37) were considered unstable due to change in MF in the bladder and WF in the PTV-All. The value of for the wavelet features was much higher than that for the original features. Out of 225 unstable wavelet features, 84 features had ≥ 1. The CVs for all the DVHs remained very small ( < 0.06). This study highlights that the sensitivity of DFs to changes in tomotherapy planning parameters is influenced by the region and the DFs, particularly wavelet features, surpassing the effectiveness of DVHs.