Effects of a Novel, Inexpensive Device “Striker” On Spatio-Temporal GaitParameters in Individuals with Parkinson’s Disease

Gurpreet Singh, Adam Strizak, Lucy Simone, Alexandra Menigoz, Adesuwa N. Eguaze
{"title":"Effects of a Novel, Inexpensive Device “Striker” On Spatio-Temporal GaitParameters in Individuals with Parkinson’s Disease","authors":"Gurpreet Singh, Adam Strizak, Lucy Simone, Alexandra Menigoz, Adesuwa N. Eguaze","doi":"10.37506/kvmrtr73","DOIUrl":null,"url":null,"abstract":"Purpose: Problems with foot mechanics (insufficient heel strike) that are seen in individuals with Parkinson’s Disease (PD), result in landing with either the middle or front of the foot.  This altered pattern contributes to instability. Proper dorsiflexion of the foot resulting in heel strike can improve gait mechanics in PD, therefore the purpose of this research is to quantify the effects of a novel device on spatiotemporal gait parameters in individuals with PD.\nMethods: 11 individuals diagnosed with Parkinson’s disease (H & Y I -III) were recruited and screened using predetermined inclusion/exclusion criteria. Each participant wore a novel device, “Striker”. All participants were tested both with and without the device in a randomly chosen order during a Six Minute Walk Test and GAITRite Mat. A researcher developed a patient survey that was provided at the end of testing to assess feasibility and confidence using the “Striker”.\nResults: The Wilcoxon Sign Rank test was utilized to compare within-group differences indicating an improvement in cadence (p = 0.003) and the associated decline in gait velocity (p = 0.004) while using Striker.\nConclusion: Significant change in cadence, while using “Striker” was associated with better biomechanics of the foot, initiating with a heel strike, thus decreasing the number of steps taken to cover the same distance. Additionally, most of the post-research surveys provided positive qualitative feedback. “Striker” may be used to improve heel strikes to decrease fall risk in individuals with PD.","PeriodicalId":516273,"journal":{"name":"Indian Journal of Physiotherapy & Occupational Therapy - An International Journal","volume":"19 9","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Physiotherapy & Occupational Therapy - An International Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.37506/kvmrtr73","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: Problems with foot mechanics (insufficient heel strike) that are seen in individuals with Parkinson’s Disease (PD), result in landing with either the middle or front of the foot.  This altered pattern contributes to instability. Proper dorsiflexion of the foot resulting in heel strike can improve gait mechanics in PD, therefore the purpose of this research is to quantify the effects of a novel device on spatiotemporal gait parameters in individuals with PD. Methods: 11 individuals diagnosed with Parkinson’s disease (H & Y I -III) were recruited and screened using predetermined inclusion/exclusion criteria. Each participant wore a novel device, “Striker”. All participants were tested both with and without the device in a randomly chosen order during a Six Minute Walk Test and GAITRite Mat. A researcher developed a patient survey that was provided at the end of testing to assess feasibility and confidence using the “Striker”. Results: The Wilcoxon Sign Rank test was utilized to compare within-group differences indicating an improvement in cadence (p = 0.003) and the associated decline in gait velocity (p = 0.004) while using Striker. Conclusion: Significant change in cadence, while using “Striker” was associated with better biomechanics of the foot, initiating with a heel strike, thus decreasing the number of steps taken to cover the same distance. Additionally, most of the post-research surveys provided positive qualitative feedback. “Striker” may be used to improve heel strikes to decrease fall risk in individuals with PD.
新型廉价设备 "Striker "对帕金森病患者时空步态参数的影响
目的:帕金森病(PD)患者的足部力学(脚跟着地不足)问题会导致患者用足中部或足前部着地。 这种改变的模式会导致不稳定性。因此,本研究的目的是量化一种新型装置对帕金森病患者时空步态参数的影响。方法:招募 11 名被诊断患有帕金森病(H & Y I - III)的患者,并按照预先确定的纳入/排除标准进行筛选。每位参与者都佩戴了一种新型装置 "Striker"。在六分钟步行测试和 GAITRite Mat 测试中,所有参与者都按照随机选择的顺序接受了佩戴和不佩戴该装置的测试。研究人员编写了一份患者调查表,在测试结束时提供,以评估使用 "Striker "的可行性和信心:采用 Wilcoxon Sign Rank 检验比较组内差异,结果表明,在使用 Striker 时,步频有所改善(p = 0.003),步速有所下降(p = 0.004):结论:在使用 "Striker "时,步频的显著变化与脚部生物力学的改善有关,即以脚跟着地开始,从而减少了相同距离所需的步数。此外,大多数研究后调查都提供了积极的定性反馈。"Striker "可用于改善脚后跟着地,从而降低老年痴呆症患者跌倒的风险。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信