Cardiopulmonary Bypass in a Pediatric Patient with Factor XII Deficiency

Julie Fenske, Julie Tinius-Juliani, Cynthia Herrington
{"title":"Cardiopulmonary Bypass in a Pediatric Patient with Factor XII Deficiency","authors":"Julie Fenske, Julie Tinius-Juliani, Cynthia Herrington","doi":"10.1051/ject/2024021","DOIUrl":null,"url":null,"abstract":"Safe use of cardiopulmonary bypass (CPB) relies upon the ability to administer, monitor, and reverse anticoagulation. Although rare, the factor XII deficient patient creates a challenge for the perfusionist due to resultant complication in monitoring anticoagulation. There have been proposed strategies to aid in monitoring anticoagulation in the factor XII deficient patient, however documentation of successful monitoring during CPB is infrequent. With use of the Hemochron Signature Elite and ACT+ cartridges, CPB in a factor XII deficient 8-month-old was completed with predictable and reliable anticoagulation monitoring. This case report explores the current suggestions as to factor XII deficiency management with CPB.","PeriodicalId":506828,"journal":{"name":"The Journal of ExtraCorporeal Technology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of ExtraCorporeal Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1051/ject/2024021","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Safe use of cardiopulmonary bypass (CPB) relies upon the ability to administer, monitor, and reverse anticoagulation. Although rare, the factor XII deficient patient creates a challenge for the perfusionist due to resultant complication in monitoring anticoagulation. There have been proposed strategies to aid in monitoring anticoagulation in the factor XII deficient patient, however documentation of successful monitoring during CPB is infrequent. With use of the Hemochron Signature Elite and ACT+ cartridges, CPB in a factor XII deficient 8-month-old was completed with predictable and reliable anticoagulation monitoring. This case report explores the current suggestions as to factor XII deficiency management with CPB.
因子 XII 缺乏症儿科患者的心肺搭桥术
安全使用心肺旁路术(CPB)有赖于管理、监测和逆转抗凝的能力。XII 因子缺乏的患者虽然罕见,但却给灌注医师带来了挑战,因为这会导致监测抗凝的复杂性。有人提出了帮助 XII 因子缺乏患者监测抗凝的策略,但在 CPB 期间成功监测的记录并不多见。使用 Hemochron Signature Elite 和 ACT+ 血盒后,一名 XII 因子缺乏的 8 个月大婴儿在可预测和可靠的抗凝监测下完成了 CPB。本病例报告探讨了目前有关 CPB 时 XII 因子缺乏症管理的建议。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信