Turn-Over Technique for Inserting and Stabilizing Guiding Sheath without Straightening It during Carotid Artery Stenting via Trans-Brachial Approach in Cases with Severe Vascular Access Conditions.

Journal of neuroendovascular therapy Pub Date : 2024-01-01 Epub Date: 2024-06-07 DOI:10.5797/jnet.tn.2024-0017
Yuki Kato, Kentaro Yamashita, Tomohiro Iida, Kodai Uematsu, Tatsuya Kuroda, Satoru Murase
{"title":"Turn-Over Technique for Inserting and Stabilizing Guiding Sheath without Straightening It during Carotid Artery Stenting via Trans-Brachial Approach in Cases with Severe Vascular Access Conditions.","authors":"Yuki Kato, Kentaro Yamashita, Tomohiro Iida, Kodai Uematsu, Tatsuya Kuroda, Satoru Murase","doi":"10.5797/jnet.tn.2024-0017","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>In cases of severe atherosclerosis or tortuous arteries, inserting the guiding sheath into the target vessel is challenging. Here, we present the turn-over technique for inserting and stabilizing the guiding sheath without straightening it during carotid artery stenting (CAS).</p><p><strong>Case presentation: </strong>Two patients with severe left internal carotid artery stenosis underwent CAS via the trans-brachial approach. Although inserting the guiding sheath into the common carotid artery using conventional techniques was challenging, we succeeded in inserting it into the target vessel using the \"turn-over technique.\" At first, the guidewire was U-turned just above the aortic valve and inserted into the left external carotid artery. The inner catheter and guiding sheath were then followed along the guidewire to the left common carotid artery, and the guidewire and inner catheter were removed. The guiding sheath was stable in a U-turned position, and straightening the guiding sheath was difficult. Devices such as stents and balloons could be delivered without problems, and CAS was completed with the guiding sheath in a U-turned position.</p><p><strong>Conclusion: </strong>The turn-over technique for inserting and stabilizing the guiding sheath for CAS via the trans-brachial approach is an option in cases of difficult catheter access due to atherosclerosis or tortuous arteries.</p>","PeriodicalId":73856,"journal":{"name":"Journal of neuroendovascular therapy","volume":"18 7","pages":"203-206"},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11260518/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of neuroendovascular therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5797/jnet.tn.2024-0017","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/7 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: In cases of severe atherosclerosis or tortuous arteries, inserting the guiding sheath into the target vessel is challenging. Here, we present the turn-over technique for inserting and stabilizing the guiding sheath without straightening it during carotid artery stenting (CAS).

Case presentation: Two patients with severe left internal carotid artery stenosis underwent CAS via the trans-brachial approach. Although inserting the guiding sheath into the common carotid artery using conventional techniques was challenging, we succeeded in inserting it into the target vessel using the "turn-over technique." At first, the guidewire was U-turned just above the aortic valve and inserted into the left external carotid artery. The inner catheter and guiding sheath were then followed along the guidewire to the left common carotid artery, and the guidewire and inner catheter were removed. The guiding sheath was stable in a U-turned position, and straightening the guiding sheath was difficult. Devices such as stents and balloons could be delivered without problems, and CAS was completed with the guiding sheath in a U-turned position.

Conclusion: The turn-over technique for inserting and stabilizing the guiding sheath for CAS via the trans-brachial approach is an option in cases of difficult catheter access due to atherosclerosis or tortuous arteries.

在严重血管通路条件下通过经肱骨入路进行颈动脉支架植入术时无需拉直导引鞘即可插入和稳定导引鞘的翻转技术
目的:在动脉粥样硬化严重或动脉迂曲的情况下,将引导鞘插入靶血管具有挑战性。在此,我们介绍在颈动脉支架植入术(CAS)中无需拉直导引鞘即可插入并稳定导引鞘的翻转技术:病例介绍:两名左侧颈内动脉严重狭窄的患者通过经肱骨入路接受了 CAS 手术。虽然使用传统技术将导引鞘插入颈总动脉具有挑战性,但我们使用 "翻转技术 "成功地将导引鞘插入了靶血管。首先,将导丝在主动脉瓣上方 U 形翻转,然后插入左侧颈外动脉。然后,内导管和引导鞘沿着导丝到达左侧颈总动脉,并移除导丝和内导管。导引鞘以 U 形翻转的姿势保持稳定,很难将导引鞘拉直。支架和球囊等设备可以顺利送入,CAS也在导引鞘处于U形翻转位置时完成:结论:对于动脉粥样硬化或动脉迂曲导致导管难以进入的病例,经肱骨入路插入并稳定导引鞘的翻转技术是一种选择。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信