{"title":"Analytical Solution and Energy Flow Analysis of a Vertical Vibration-Controlled System Using the Nonlinear Energy Sink","authors":"Decheng Lu, Peng Chen, Dingsong Zhou","doi":"10.1155/2024/5549289","DOIUrl":null,"url":null,"abstract":"<div>\n <p>The nonlinear energy sink (NES) has drawn increasing research attention in recent years. In this study, we investigated a novel disc spring-based vertical NES device capable of counterbalancing payload gravity and providing a combination of linear and cubic restoring forces. The vertical NES device is used to mitigate vibration responses in vertically flexible structures caused by human or machinery-induced actions. To simplify the NES controlled system, a two-degree-of-freedom model was used to account for harmonic forces acting on the primary structure. Using the complexification-averaging (CX-A) method, we obtained the frequency-amplitude solution and subsequently derived the force transmissibility (<i>T</i><sub>f</sub>). Parametric comparisons between the NES and traditional tuned mass damper (TMD)-controlled systems were performed by comparing the <i>T</i><sub>f</sub> curves and numerically verifying the theoretical solutions. Results confirmed the accuracy of the theoretical force transmissibility solutions and affirmed the advantage of the NES system by overcoming the limited operating frequency bandwidth of the traditional TMD system. The inclusion of a linear stiffness term in an NES system has been shown to enhance the vibration control performance within the resonant frequency bandwidth. In addition, the time history energy analysis for the NES and TMD systems was conducted. The energy flow analysis elucidated the broad operating bandwidth of the NES system. This finding suggests that the vibration energy flow to the attachment in the NES system is irreversible, thereby preventing amplification of the response in the primary structure, even when the system is mistuned.</p>\n </div>","PeriodicalId":49471,"journal":{"name":"Structural Control & Health Monitoring","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-07-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1155/2024/5549289","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Structural Control & Health Monitoring","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1155/2024/5549289","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
The nonlinear energy sink (NES) has drawn increasing research attention in recent years. In this study, we investigated a novel disc spring-based vertical NES device capable of counterbalancing payload gravity and providing a combination of linear and cubic restoring forces. The vertical NES device is used to mitigate vibration responses in vertically flexible structures caused by human or machinery-induced actions. To simplify the NES controlled system, a two-degree-of-freedom model was used to account for harmonic forces acting on the primary structure. Using the complexification-averaging (CX-A) method, we obtained the frequency-amplitude solution and subsequently derived the force transmissibility (Tf). Parametric comparisons between the NES and traditional tuned mass damper (TMD)-controlled systems were performed by comparing the Tf curves and numerically verifying the theoretical solutions. Results confirmed the accuracy of the theoretical force transmissibility solutions and affirmed the advantage of the NES system by overcoming the limited operating frequency bandwidth of the traditional TMD system. The inclusion of a linear stiffness term in an NES system has been shown to enhance the vibration control performance within the resonant frequency bandwidth. In addition, the time history energy analysis for the NES and TMD systems was conducted. The energy flow analysis elucidated the broad operating bandwidth of the NES system. This finding suggests that the vibration energy flow to the attachment in the NES system is irreversible, thereby preventing amplification of the response in the primary structure, even when the system is mistuned.
近年来,非线性能量汇(NES)引起了越来越多的研究关注。在本研究中,我们研究了一种基于碟形弹簧的新型垂直 NES 装置,该装置能够平衡有效载荷重力,并提供线性和立方恢复力组合。垂直 NES 装置可用于减轻垂直柔性结构中由人为或机械引起的振动响应。为了简化 NES 受控系统,使用了一个双自由度模型来考虑作用在主结构上的谐波力。我们使用复合平均(CX-A)方法获得了频率-振幅解,随后得出了力传递率(Tf)。通过比较 Tf 曲线和对理论解进行数值验证,我们对 NES 和传统的调谐质量阻尼器 (TMD) 控制系统进行了参数比较。结果证实了力传递理论解的准确性,并肯定了 NES 系统克服传统 TMD 系统有限工作频率带宽的优势。事实证明,在 NES 系统中加入线性刚度项可以提高共振频率带宽内的振动控制性能。此外,还对 NES 和 TMD 系统进行了时间历程能量分析。能量流分析阐明了 NES 系统宽广的工作带宽。这一发现表明,在 NES 系统中,流向附件的振动能量是不可逆的,因此即使在系统失谐的情况下,也能防止主结构的响应放大。
期刊介绍:
The Journal Structural Control and Health Monitoring encompasses all theoretical and technological aspects of structural control, structural health monitoring theory and smart materials and structures. The journal focuses on aerospace, civil, infrastructure and mechanical engineering applications.
Original contributions based on analytical, computational and experimental methods are solicited in three main areas: monitoring, control, and smart materials and structures, covering subjects such as system identification, health monitoring, health diagnostics, multi-functional materials, signal processing, sensor technology, passive, active and semi active control schemes and implementations, shape memory alloys, piezoelectrics and mechatronics.
Also of interest are actuator design, dynamic systems, dynamic stability, artificial intelligence tools, data acquisition, wireless communications, measurements, MEMS/NEMS sensors for local damage detection, optical fibre sensors for health monitoring, remote control of monitoring systems, sensor-logger combinations for mobile applications, corrosion sensors, scour indicators and experimental techniques.