{"title":"Anthropomorphic abdominal aortic phantoms for computed tomography angiography","authors":"Anastasia V. Guseva, M. Kodenko","doi":"10.17816/dd626820","DOIUrl":null,"url":null,"abstract":"BACKGROUND: Anthropomorphic vascular test objects are an important tool for improving computed tomography angiography studies, as they allow avoiding the impact of radiation exposure on the patient. The presented work is a continuation of the research in the field of development and implementation of the system of pulse blood flow simulation of vessels for computed tomography angiography studies. Based on the results of successful validation of the experimental test bench using simplified test objects [1], the work on creation of anthropomorphic test objects of the abdominal aorta imitating normal and aneurysmatically dilated vessels was initiated and carried out. \nAIM: Creation of anthropomorphic test objects of the abdominal aorta from materials that simultaneously mimic the biomechanical and X-ray properties of the real vessel. \nMATERIALS AND METHODS: Publicly available computed tomography data of patients were selected to create anthropomorphic test objects [2]. 3D Slicer software was used to segment studies containing normal and aneurysmatically dilated abdominal aortic lumen. The models obtained during segmentation were processed using Autodesk Meshmixer computer-aided design system. Model preparation for printing was performed using Polygon X computer-aided design system. The models were printed from water-soluble plastic using Picaso X PRO 3D printer. The resulting model was used as the basis for creating a test object using the smearing method. In order to ensure uniform thickness of the vessel wall, a structure, which is a rotating frame with adjustable speed, was developed. A combination of silicone matrix and reinforcing threads was used as a tissueimitating material with the required X-ray and biomechanical properties [3]. \nRESULTS: Anthropomorphic test objects were made for cases of normal and aneurysmatically dilated abdominal aortic lumen in 1:3 and 1:1 scale. A technological process of material application was developed, which made it possible to obtain a uniform layer of material over the entire volume of the model. \nCONCLUSION: The results are intended for the development of computed tomography angiographyusing anthropomorphic test objects that allow taking into account the individual characteristics of the patient. Further development of the project involves testing of the obtained test objects within the framework of computed tomography angiography research using a device simulating pulse blood flow.","PeriodicalId":34831,"journal":{"name":"Digital Diagnostics","volume":"128 3","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Digital Diagnostics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17816/dd626820","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
BACKGROUND: Anthropomorphic vascular test objects are an important tool for improving computed tomography angiography studies, as they allow avoiding the impact of radiation exposure on the patient. The presented work is a continuation of the research in the field of development and implementation of the system of pulse blood flow simulation of vessels for computed tomography angiography studies. Based on the results of successful validation of the experimental test bench using simplified test objects [1], the work on creation of anthropomorphic test objects of the abdominal aorta imitating normal and aneurysmatically dilated vessels was initiated and carried out.
AIM: Creation of anthropomorphic test objects of the abdominal aorta from materials that simultaneously mimic the biomechanical and X-ray properties of the real vessel.
MATERIALS AND METHODS: Publicly available computed tomography data of patients were selected to create anthropomorphic test objects [2]. 3D Slicer software was used to segment studies containing normal and aneurysmatically dilated abdominal aortic lumen. The models obtained during segmentation were processed using Autodesk Meshmixer computer-aided design system. Model preparation for printing was performed using Polygon X computer-aided design system. The models were printed from water-soluble plastic using Picaso X PRO 3D printer. The resulting model was used as the basis for creating a test object using the smearing method. In order to ensure uniform thickness of the vessel wall, a structure, which is a rotating frame with adjustable speed, was developed. A combination of silicone matrix and reinforcing threads was used as a tissueimitating material with the required X-ray and biomechanical properties [3].
RESULTS: Anthropomorphic test objects were made for cases of normal and aneurysmatically dilated abdominal aortic lumen in 1:3 and 1:1 scale. A technological process of material application was developed, which made it possible to obtain a uniform layer of material over the entire volume of the model.
CONCLUSION: The results are intended for the development of computed tomography angiographyusing anthropomorphic test objects that allow taking into account the individual characteristics of the patient. Further development of the project involves testing of the obtained test objects within the framework of computed tomography angiography research using a device simulating pulse blood flow.
背景:拟人化血管测试对象是改进计算机断层扫描血管成像研究的重要工具,因为它们可以避免辐射对病人的影响。本文介绍的工作是计算机断层扫描血管成像研究中血管脉冲血流模拟系统开发和实施领域研究的继续。在使用简化测试对象成功验证实验测试台的结果[1]的基础上,开始并实施了仿造正常血管和动脉瘤扩张血管的腹主动脉拟人测试对象的创建工作。目的:用能同时模拟真实血管的生物力学和 X 射线特性的材料制作腹主动脉拟人化测试物体。材料和方法:选择公开的患者计算机断层扫描数据来创建拟人测试对象[2]。使用 3D Slicer 软件对包含正常和动脉瘤扩张腹主动脉管腔的研究进行分割。分割过程中获得的模型使用 Autodesk Meshmixer 计算机辅助设计系统进行处理。打印模型的准备工作使用 Polygon X 计算机辅助设计系统进行。使用 Picaso X PRO 三维打印机用水溶性塑料打印模型。生成的模型被用作使用涂抹法创建测试对象的基础。为了确保血管壁的厚度均匀一致,我们开发了一种结构,即一个速度可调的旋转框架。硅酮基质和加强线的组合被用作组织模拟材料,具有所需的 X 射线和生物力学特性[3]。结果:以 1:3 和 1:1 的比例为正常和动脉瘤扩张的腹主动脉管腔制作了拟人化的测试对象。开发了一种材料应用技术流程,从而可以在模型的整个体积上获得均匀的材料层。结论:该成果旨在利用拟人化测试对象开发计算机断层扫描血管成像技术,从而考虑到病人的个体特征。该项目的进一步发展包括在计算机断层扫描血管成像研究框架内使用模拟脉搏血流的设备对获得的测试对象进行测试。