Learning Curve in Two-Port Laparoscopic Gastropexy Using FlexDex

Animals Pub Date : 2024-07-09 DOI:10.3390/ani14142016
Federico Massari, Gary Matthew Martin Kelly
{"title":"Learning Curve in Two-Port Laparoscopic Gastropexy Using FlexDex","authors":"Federico Massari, Gary Matthew Martin Kelly","doi":"10.3390/ani14142016","DOIUrl":null,"url":null,"abstract":"Objectives: Keyhole gastropexy is becoming increasingly popular, and the new development facilitates shorter surgical times. This paper reports on the learning curve in two-port laparoscopic gastropexy using FlexDex in a specialist’s hands. FlexDex is a novel tool combining aspects of robotic surgery without requiring an expensive robot theatre setting. Methods: Cohort of 16 dogs >25 kg and at high risk of gastric volvulus and dilatation (GDV) undergoing elective laparoscopic gastropexy were enrolled in the study consecutively from 5/2022 to 9/2023. All patients were operated on by one surgeon (FM), and surgical time was recorded to assess learning curve. Competence was defined as plateauing surgical time. Detailed follow-up at 1 day, 7 days, 14 days, 2 months, 6 months, and long-term was recorded for success rate and complications. Ultrasound examination was scheduled at 4–6-month review to confirm lasting success of the gastropexy. Results: All 16 patients were operated on successfully without any significant complications, as confirmed on the ultrasound. The surgical time of laparoscopic gastropexy reduced from 52 to 14 min (reduction of 38 min/73%) and reached plateau after the 12th case of the 16, making it a very steep learning curve in specialist hands. There were no serious complications, and success rate was 100% at the 6-month ultrasound assessment. Clinical Significance: This is the first paper to report on the learning curve with the FlexDex device in a two-port laparoscopic gastropexy setting. It effectively halves the operating time to 30 min, making the surgery safer for the patient and more cost-efficient, without compromising the result.","PeriodicalId":502248,"journal":{"name":"Animals","volume":"101 22","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Animals","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/ani14142016","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: Keyhole gastropexy is becoming increasingly popular, and the new development facilitates shorter surgical times. This paper reports on the learning curve in two-port laparoscopic gastropexy using FlexDex in a specialist’s hands. FlexDex is a novel tool combining aspects of robotic surgery without requiring an expensive robot theatre setting. Methods: Cohort of 16 dogs >25 kg and at high risk of gastric volvulus and dilatation (GDV) undergoing elective laparoscopic gastropexy were enrolled in the study consecutively from 5/2022 to 9/2023. All patients were operated on by one surgeon (FM), and surgical time was recorded to assess learning curve. Competence was defined as plateauing surgical time. Detailed follow-up at 1 day, 7 days, 14 days, 2 months, 6 months, and long-term was recorded for success rate and complications. Ultrasound examination was scheduled at 4–6-month review to confirm lasting success of the gastropexy. Results: All 16 patients were operated on successfully without any significant complications, as confirmed on the ultrasound. The surgical time of laparoscopic gastropexy reduced from 52 to 14 min (reduction of 38 min/73%) and reached plateau after the 12th case of the 16, making it a very steep learning curve in specialist hands. There were no serious complications, and success rate was 100% at the 6-month ultrasound assessment. Clinical Significance: This is the first paper to report on the learning curve with the FlexDex device in a two-port laparoscopic gastropexy setting. It effectively halves the operating time to 30 min, making the surgery safer for the patient and more cost-efficient, without compromising the result.
使用 FlexDex 的双孔腹腔镜胃切除术学习曲线
目的:锁孔胃切除术越来越受欢迎,新技术的发展有助于缩短手术时间。本文报告了专家使用 FlexDex 进行双孔腹腔镜胃切除术的学习曲线。FlexDex 是一种结合了机器人手术各个方面的新型工具,无需昂贵的机器人手术室环境。手术方法在 2022 年 5 月至 2023 年 9 月期间,连续招募了 16 只体重大于 25 千克、有胃扩张(GDV)高风险的犬只接受择期腹腔镜胃切除术。所有患者均由一名外科医生(FM)进行手术,并记录手术时间以评估学习曲线。手术时间趋于平稳即为合格。详细记录了 1 天、7 天、14 天、2 个月、6 个月和长期随访的成功率和并发症。计划在 4-6 个月复查时进行超声波检查,以确认胃切除术的持久成功。结果:经超声波检查证实,16 名患者均成功完成手术,无任何明显并发症。腹腔镜胃切除术的手术时间从 52 分钟缩短至 14 分钟(缩短了 38 分钟/73%),在 16 例患者中的第 12 例后达到高峰,因此在专家手中,这是一个非常陡峭的学习曲线。没有出现严重的并发症,在 6 个月的超声波评估中,成功率为 100%。临床意义:这是第一篇报告双孔腹腔镜胃镜下 FlexDex 装置学习曲线的论文。它有效地将手术时间减半至 30 分钟,使手术对患者更安全、更经济,同时不影响手术效果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信