Paradoxical generator impedance behavior during catheter ablation in a patient with severe polycythemia

IF 2.2 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS
Takayuki Sekihara MD, Tomoaki Nakano MD, Akira Yoshida MD, PhD, Takafumi Oka MD, PhD, Yasushi Sakata MD, PhD
{"title":"Paradoxical generator impedance behavior during catheter ablation in a patient with severe polycythemia","authors":"Takayuki Sekihara MD,&nbsp;Tomoaki Nakano MD,&nbsp;Akira Yoshida MD, PhD,&nbsp;Takafumi Oka MD, PhD,&nbsp;Yasushi Sakata MD, PhD","doi":"10.1002/joa3.13115","DOIUrl":null,"url":null,"abstract":"<p>An extremely high generator impedance in the blood pool can be observed in a patient with severe polycythemia. However, ablation can be performed safely as long as the generator impedance during contact with the myocardial tissue is within acceptable limits.\n <figure>\n <div><picture>\n <source></source></picture><p></p>\n </div>\n </figure></p>","PeriodicalId":15174,"journal":{"name":"Journal of Arrhythmia","volume":"40 4","pages":"1045-1048"},"PeriodicalIF":2.2000,"publicationDate":"2024-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/joa3.13115","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Arrhythmia","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/joa3.13115","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

An extremely high generator impedance in the blood pool can be observed in a patient with severe polycythemia. However, ablation can be performed safely as long as the generator impedance during contact with the myocardial tissue is within acceptable limits.

Abstract Image

一名重度多血症患者在导管消融过程中出现的反常发电机阻抗行为
在严重多血症患者的血池中可观察到极高的发生器阻抗。不过,只要发生器与心肌组织接触时的阻抗在可接受的范围内,消融手术就可以安全进行。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Arrhythmia
Journal of Arrhythmia CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
2.90
自引率
10.00%
发文量
127
审稿时长
45 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信