{"title":"Mathematical model of a three-stage vacuum ejector system","authors":"R. Matysko","doi":"10.24425/ather.2024.150876","DOIUrl":null,"url":null,"abstract":"This paper presents a mathematical model of a vapour vacuum system, which is a crucial component of steam power plants of critical importance for energy efficiency. This system consists of three stages, with each stage containing a steam ejector and a gas phase separator in the form of an interstage heat exchanger. The primary purpose of this system is to remove inert gases and maintain the appropriate level of vacuum in the power plant condenser. The presented mathematical model can be used to analyse the operation of the vacuum system in a steady state. Preliminary pressure calculations in various components of the vacuum system show the influence of additional measurement orifice resistance on the vacuum drop in the condenser, which can reduce the efficiency of the entire energy system. It is worth noting that the presented model can be used as a tool for analysing elements of the vacuum system in energy systems.","PeriodicalId":0,"journal":{"name":"","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"2024-07-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24425/ather.2024.150876","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
This paper presents a mathematical model of a vapour vacuum system, which is a crucial component of steam power plants of critical importance for energy efficiency. This system consists of three stages, with each stage containing a steam ejector and a gas phase separator in the form of an interstage heat exchanger. The primary purpose of this system is to remove inert gases and maintain the appropriate level of vacuum in the power plant condenser. The presented mathematical model can be used to analyse the operation of the vacuum system in a steady state. Preliminary pressure calculations in various components of the vacuum system show the influence of additional measurement orifice resistance on the vacuum drop in the condenser, which can reduce the efficiency of the entire energy system. It is worth noting that the presented model can be used as a tool for analysing elements of the vacuum system in energy systems.