Analysis of a New Asymmetric Biased-Flux Operation for an Inter-Modular Permanent Magnet Motor

Energies Pub Date : 2024-07-13 DOI:10.3390/en17143459
Mohammad Afrank, Mohammad Amirkhani, Ehsan Farmahini Farahani, M. Mirsalim, A. Khorsandi, Nick J. Baker
{"title":"Analysis of a New Asymmetric Biased-Flux Operation for an Inter-Modular Permanent Magnet Motor","authors":"Mohammad Afrank, Mohammad Amirkhani, Ehsan Farmahini Farahani, M. Mirsalim, A. Khorsandi, Nick J. Baker","doi":"10.3390/en17143459","DOIUrl":null,"url":null,"abstract":"Net zero and electrification targets are continuing to enforce a need for the development of high-performance electrical machines, increasingly based on the use of rare earth permanent magnets. Biased flux motors have the potential to overcome some of the disadvantages associated with more conventional electrical machines. Since their introduction, there has been a consistent trend towards new and improved topologies, all relying on the same principles of operation. In this paper, a new alternative operation is proposed where the magnetic flux density offset of each module is different. The resulting asymmetric biased excitations of the magnets leads to a flux concentration in the air gap. Placement of magnets in the slot-opening area is shown to produce a higher average torque at a higher power factor. It is mathematically shown that the conventional methods used to investigate the effect of each group of magnets separately cannot be used for the explanation of this operation principle. Therefore, it is necessary to simultaneously consider both groups of magnets in the magnetic equivalent circuit. Due to the use of magnets in these motors, thermal conditions are also investigated. Finally, a comprehensive comparison between several stator-situated-magnet motors is presented. The performance of the proposed motor is improved in terms of average torque, torque density, PM torque density, power factor, and overload capability. The torque density specifically has increased by 9%. Moreover, both motors have suitable thermal behaviour which confirms the validity of the demagnetization analysis.","PeriodicalId":504870,"journal":{"name":"Energies","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-07-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Energies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/en17143459","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Net zero and electrification targets are continuing to enforce a need for the development of high-performance electrical machines, increasingly based on the use of rare earth permanent magnets. Biased flux motors have the potential to overcome some of the disadvantages associated with more conventional electrical machines. Since their introduction, there has been a consistent trend towards new and improved topologies, all relying on the same principles of operation. In this paper, a new alternative operation is proposed where the magnetic flux density offset of each module is different. The resulting asymmetric biased excitations of the magnets leads to a flux concentration in the air gap. Placement of magnets in the slot-opening area is shown to produce a higher average torque at a higher power factor. It is mathematically shown that the conventional methods used to investigate the effect of each group of magnets separately cannot be used for the explanation of this operation principle. Therefore, it is necessary to simultaneously consider both groups of magnets in the magnetic equivalent circuit. Due to the use of magnets in these motors, thermal conditions are also investigated. Finally, a comprehensive comparison between several stator-situated-magnet motors is presented. The performance of the proposed motor is improved in terms of average torque, torque density, PM torque density, power factor, and overload capability. The torque density specifically has increased by 9%. Moreover, both motors have suitable thermal behaviour which confirms the validity of the demagnetization analysis.
模块间永磁电机的新型不对称偏置磁通运行分析
净零排放和电气化目标的实现不断要求人们开发高性能电机,而这些电机越来越多地以使用稀土永磁体为基础。偏磁通量电机有可能克服与传统电机相关的一些缺点。自问世以来,新的和改进的拓扑结构一直是大势所趋,但都依赖于相同的运行原理。本文提出了一种新的替代运行方式,即每个模块的磁通密度偏移不同。由此产生的磁铁非对称偏置激磁会导致磁通量集中在气隙中。在开槽区域放置磁铁可在更高的功率因数下产生更大的平均扭矩。数学证明,用于单独研究每组磁体影响的传统方法无法用于解释该运行原理。因此,有必要在磁性等效电路中同时考虑两组磁体。由于在这些电机中使用了磁铁,因此还对热条件进行了研究。最后,对几种定子定位磁铁电机进行了综合比较。建议的电机在平均转矩、转矩密度、永磁转矩密度、功率因数和过载能力方面的性能都有所提高。尤其是转矩密度提高了 9%。此外,两台电机都具有合适的热性能,这证实了退磁分析的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信