Separation and Validation of Comprehensive Impurities in Erythromycin Tablets by using Rp-HPLC method

GarimiTirumala Jyothesh Kumar, N Kumar, P. Sunil Reddy, B.S.A. Andrews
{"title":"Separation and Validation of Comprehensive Impurities in Erythromycin Tablets by using Rp-HPLC method","authors":"GarimiTirumala Jyothesh Kumar, N Kumar, P. Sunil Reddy, B.S.A. Andrews","doi":"10.47392/irjaem.2024.0321","DOIUrl":null,"url":null,"abstract":"In this study a simple, rapid, accurate and precise gradientRP-HPLC method has been developed and validated for the separation of impurities (IMP) in Erythromycin (ERT-A) tablets pharmaceutical dosage form. The chromatographic separation was carried out on WatersX-Terra RP 18 (250 mm x 4.6 mm I.D., 3.5 µm particle size) at 65°C was used for this separation. Mobile Phase-A consists of Buffersolution (35 g of di-potassium hydrogen phosphate in 1000mL of water, adjust the pH7.0with dilute o-phosphoric acid, filtered through 0.45 µm membrane filter) acetonitrile and water in ratio of 5:35:60 v/v/v respectively. Mobile Phase-B consists of a mixture of phosphate buffer pH 7.0, water and acetonitrile in ratio of 5:45:50 v/v/v respectively .The flow rate and injection volume was 1.0 mL/min and 100 μL respectively. The analysis was carried out under the gradient conditions as time (min)/A (v/v): B(v/v); T0/100:00, T45/100:00, T47/0:100, T63/0:100, T65/100:00, and T70/100:00. The wavelength was identified at 215 nm. The ERT-Adegrades under various circumstances. The degradation products were well resolved from the ERT peaks. This method was found to be linear.  The cumulative %RSD values are ;identified and found that they are within the range.  From the study concluded that the method is accurate, specific, selective, precise, robust, and useful during the process development and quality check in finished dosage form manufacturing.","PeriodicalId":517878,"journal":{"name":"International Research Journal on Advanced Engineering and Management (IRJAEM)","volume":"28 20","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Research Journal on Advanced Engineering and Management (IRJAEM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47392/irjaem.2024.0321","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In this study a simple, rapid, accurate and precise gradientRP-HPLC method has been developed and validated for the separation of impurities (IMP) in Erythromycin (ERT-A) tablets pharmaceutical dosage form. The chromatographic separation was carried out on WatersX-Terra RP 18 (250 mm x 4.6 mm I.D., 3.5 µm particle size) at 65°C was used for this separation. Mobile Phase-A consists of Buffersolution (35 g of di-potassium hydrogen phosphate in 1000mL of water, adjust the pH7.0with dilute o-phosphoric acid, filtered through 0.45 µm membrane filter) acetonitrile and water in ratio of 5:35:60 v/v/v respectively. Mobile Phase-B consists of a mixture of phosphate buffer pH 7.0, water and acetonitrile in ratio of 5:45:50 v/v/v respectively .The flow rate and injection volume was 1.0 mL/min and 100 μL respectively. The analysis was carried out under the gradient conditions as time (min)/A (v/v): B(v/v); T0/100:00, T45/100:00, T47/0:100, T63/0:100, T65/100:00, and T70/100:00. The wavelength was identified at 215 nm. The ERT-Adegrades under various circumstances. The degradation products were well resolved from the ERT peaks. This method was found to be linear.  The cumulative %RSD values are ;identified and found that they are within the range.  From the study concluded that the method is accurate, specific, selective, precise, robust, and useful during the process development and quality check in finished dosage form manufacturing.
利用 Rp-HPLC 方法分离和验证红霉素片中的综合杂质
本研究针对红霉素片剂(ERT-A)药物剂型中杂质(IMP)的分离,建立并验证了一种简单、快速、准确、精确的梯度 RP-HPLC 方法。色谱分离采用 WatersX-Terra RP 18 (250 mm x 4.6 mm I.D., 3.5 µm particle size),分离温度为 65°C。流动相 A 由缓冲溶液(35 克磷酸氢二钾溶于 1000 毫升水中,用稀磷酸调节 pH7.0,经 0.45 微米滤膜过滤)、乙腈和水组成,比例分别为 5:35:60 v/v/v。流动相-B 由 pH 值为 7.0 的磷酸盐缓冲液、水和乙腈的混合物组成,三者的比例分别为 5:45:50 v/v/v,流速和进样量分别为 1.0 mL/min 和 100 μL。分析在时间(分钟)/A(v/v)的梯度条件下进行:B(v/v);T0/100:00、T45/100:00、T47/0:100、T63/0:100、T65/100:00 和 T70/100:00。波长确定为 215 纳米。ERT 会在各种情况下降解。降解产物从 ERT 峰中很好地分离出来。该方法线性良好。 确定了累积 %RSD 值,发现它们都在范围之内。 研究认为,该方法准确、特异、选择性强、精确、稳健,在制剂成品的工艺开发和质量检查中非常有用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信