Timed up and go and 30-S chair-stand tests applied via video call are reliable and provide results similar to face-to-face assessment of older adults with different musculoskeletal conditions
{"title":"Timed up and go and 30-S chair-stand tests applied via video call are reliable and provide results similar to face-to-face assessment of older adults with different musculoskeletal conditions","authors":"Jane Fonseca Dias, Rosana Ferreira Sampaio, Pollyana Ruggio Tristão Borges, Juliana Melo Ocarino, Renan Alves Resende","doi":"10.1016/j.jbmt.2024.07.021","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Remote assessments are promising for coping with adverse situations, such as those imposed by the COVID-19 pandemic. Measurement properties must be specific to the characteristics of the population and the context in which the instruments are used.</p></div><div><h3>Purpose</h3><p><em>s</em>: 1) To evaluate the parallel reliability of the timed up and go (TUG) and 30-s chair-stand test (30CST) performed in-person and remotely and 2) to analyze the intra-rater, inter-rater, and test-retest reliability of these tests assessed remotely in older adults with different musculoskeletal conditions.</p></div><div><h3>Methods</h3><p>The sample included 50 older adults. Parallel reliability was determined by comparing in-person and remote data. Bland-Altman plots displayed differences between tests (TUG and 30CST) performed in-person and remotely, showing the mean scores of each participant. The intra-rater, inter-rater, and test-retest reliability for remote assessments were analyzed using the intraclass correlation coefficient (ICC) with a 95% confidence interval.</p></div><div><h3>Results</h3><p>Parallel reliability was high between in-person and remote assessments (ICC >0.82). Intra-rater, inter-rater, and test-retest reliability were very high for remote assessments (ICC >0.90). The minimal detectable change for the remote assessment of TUG (MDC <1.95) and 30CST (MDC <2.39) indicated adequate sensitivity. In both tests, the standard error of the measurement was acceptable (SEM% < 10%) and Bland-Altman limits of agreement were solid.</p></div><div><h3>Conclusions</h3><p>The remote assessment of TUG and 30CST in older adults with different musculoskeletal conditions was as reliable as those performed in person and may be considered when in-person assessments are impossible.</p></div>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-07-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1360859224003577","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Background
Remote assessments are promising for coping with adverse situations, such as those imposed by the COVID-19 pandemic. Measurement properties must be specific to the characteristics of the population and the context in which the instruments are used.
Purpose
s: 1) To evaluate the parallel reliability of the timed up and go (TUG) and 30-s chair-stand test (30CST) performed in-person and remotely and 2) to analyze the intra-rater, inter-rater, and test-retest reliability of these tests assessed remotely in older adults with different musculoskeletal conditions.
Methods
The sample included 50 older adults. Parallel reliability was determined by comparing in-person and remote data. Bland-Altman plots displayed differences between tests (TUG and 30CST) performed in-person and remotely, showing the mean scores of each participant. The intra-rater, inter-rater, and test-retest reliability for remote assessments were analyzed using the intraclass correlation coefficient (ICC) with a 95% confidence interval.
Results
Parallel reliability was high between in-person and remote assessments (ICC >0.82). Intra-rater, inter-rater, and test-retest reliability were very high for remote assessments (ICC >0.90). The minimal detectable change for the remote assessment of TUG (MDC <1.95) and 30CST (MDC <2.39) indicated adequate sensitivity. In both tests, the standard error of the measurement was acceptable (SEM% < 10%) and Bland-Altman limits of agreement were solid.
Conclusions
The remote assessment of TUG and 30CST in older adults with different musculoskeletal conditions was as reliable as those performed in person and may be considered when in-person assessments are impossible.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.