Can a negative d-dimer rule out pulmonary embolism in patients with COVID-19?

Erin L. Simon , Mary Bozsik , Micaela Abbomerato , Caroline Mangira , Jessica Krizo
{"title":"Can a negative d-dimer rule out pulmonary embolism in patients with COVID-19?","authors":"Erin L. Simon ,&nbsp;Mary Bozsik ,&nbsp;Micaela Abbomerato ,&nbsp;Caroline Mangira ,&nbsp;Jessica Krizo","doi":"10.1016/j.jemrpt.2024.100100","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Globally, there have been more than 771 million confirmed cases of COVID-19 and more than 6.9 million deaths. The relationship between Covid-19 and pulmonary embolism (PE) has been well-established.</p></div><div><h3>Objectives</h3><p>We evaluated the correlation between normal D-dimer levels and negative findings on computed tomography pulmonary angiogram (CTPA) to assess its predictive value. Additionally, we determined the sensitivity and specificity of a D-dimer in COVID-19 (+) patients.</p></div><div><h3>Methods</h3><p>This was a retrospective cohort study of all adult patients presenting to one of 17 EDs within a large integrated healthcare system between March 1, 2020, and December 31, 2021, who were diagnosed with COVID-19 and had a D-dimer and CTPA as part of their clinical workup. This study includes EDs in urban, suburban, and rural areas. Sensitivity and specificity were calculated to assess the performance of D-dimer tests in discriminating those with and without PE. Multiple logistic regression was used to assess the effect of D-dimer test results in predicting PE.</p></div><div><h3>Results</h3><p>A total of 3133 patients were included in this study (Fig. 1). Of 3133 patients, 2846 (91 ​%) had an abnormal D-dimer, and 287 (9 ​%) had a normal D-dimer. In the group with the abnormal D-dimer, 145 (5 ​%) had a PE on CTPA. In the group with the normal D-dimer, 285 (99.3 ​%) patients did not have a PE on CTPA. The sensitivity of D-dimer in this population was 98.6 ​%, and the specificity was 9.5 ​%. Patients with abnormal D-dimer levels were 7.86 times more likely to have a PE.</p></div><div><h3>Conclusion</h3><p>In conclusion, our study found that PE could be safely excluded for COVID-19 (+) patients with a normal or age-adjusted D-dimer.</p></div>","PeriodicalId":73546,"journal":{"name":"JEM reports","volume":"3 3","pages":"Article 100100"},"PeriodicalIF":0.0000,"publicationDate":"2024-07-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2773232024000300/pdfft?md5=2ad8744c999457e51c3658c1dfac18a3&pid=1-s2.0-S2773232024000300-main.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JEM reports","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2773232024000300","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background

Globally, there have been more than 771 million confirmed cases of COVID-19 and more than 6.9 million deaths. The relationship between Covid-19 and pulmonary embolism (PE) has been well-established.

Objectives

We evaluated the correlation between normal D-dimer levels and negative findings on computed tomography pulmonary angiogram (CTPA) to assess its predictive value. Additionally, we determined the sensitivity and specificity of a D-dimer in COVID-19 (+) patients.

Methods

This was a retrospective cohort study of all adult patients presenting to one of 17 EDs within a large integrated healthcare system between March 1, 2020, and December 31, 2021, who were diagnosed with COVID-19 and had a D-dimer and CTPA as part of their clinical workup. This study includes EDs in urban, suburban, and rural areas. Sensitivity and specificity were calculated to assess the performance of D-dimer tests in discriminating those with and without PE. Multiple logistic regression was used to assess the effect of D-dimer test results in predicting PE.

Results

A total of 3133 patients were included in this study (Fig. 1). Of 3133 patients, 2846 (91 ​%) had an abnormal D-dimer, and 287 (9 ​%) had a normal D-dimer. In the group with the abnormal D-dimer, 145 (5 ​%) had a PE on CTPA. In the group with the normal D-dimer, 285 (99.3 ​%) patients did not have a PE on CTPA. The sensitivity of D-dimer in this population was 98.6 ​%, and the specificity was 9.5 ​%. Patients with abnormal D-dimer levels were 7.86 times more likely to have a PE.

Conclusion

In conclusion, our study found that PE could be safely excluded for COVID-19 (+) patients with a normal or age-adjusted D-dimer.

d 二聚体阴性能否排除 COVID-19 患者的肺栓塞?
背景全球已确诊的 COVID-19 病例超过 7.71 亿例,死亡人数超过 690 万。我们评估了 D-二聚体水平正常与计算机断层扫描肺血管造影(CTPA)阴性结果之间的相关性,以评估其预测价值。此外,我们还确定了 D-二聚体在 COVID-19 (+) 患者中的敏感性和特异性。方法这是一项回顾性队列研究,研究对象是 2020 年 3 月 1 日至 2021 年 12 月 31 日期间在大型综合医疗系统内的 17 家急诊室之一就诊的所有成年患者,这些患者被诊断为 COVID-19,并在临床检查中进行了 D-二聚体和 CTPA 检查。这项研究包括城市、郊区和农村地区的急诊室。通过计算灵敏度和特异性来评估 D-二聚体检测在区分 PE 患者和非 PE 患者方面的性能。本研究共纳入了 3133 名患者(图 1)。在3133名患者中,2846人(91%)D-二聚体异常,287人(9%)D-二聚体正常。在 D-二聚体异常组中,145 人(5%)在 CTPA 检查中出现 PE。在 D-二聚体正常组中,有 285 名患者(99.3%)在 CTPA 检查中没有出现 PE。在这一人群中,D-二聚体的敏感性为 98.6%,特异性为 9.5%。总之,我们的研究发现,D-二聚体正常或经年龄调整的 COVID-19 (+) 患者可以安全地排除 PE。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
JEM reports
JEM reports Emergency Medicine
自引率
0.00%
发文量
0
审稿时长
54 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信