A comparison of target volumes drawn on arterial and venous phase scans during radiation therapy planning for patients with pancreatic cancer: the PANCRINJ study.

IF 3.3 2区 医学 Q2 ONCOLOGY
Fabien Zaidi, Paul Calame, Cédric Chevalier, Julie Henriques, Dewi Vernerey, Lucine Vuitton, Bruno Heyd, Christophe Borg, Jihane Boustani
{"title":"A comparison of target volumes drawn on arterial and venous phase scans during radiation therapy planning for patients with pancreatic cancer: the PANCRINJ study.","authors":"Fabien Zaidi, Paul Calame, Cédric Chevalier, Julie Henriques, Dewi Vernerey, Lucine Vuitton, Bruno Heyd, Christophe Borg, Jihane Boustani","doi":"10.1186/s13014-024-02477-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The planification of radiation therapy (RT) for pancreatic cancer (PC) requires a dosimetric computed tomography (CT) scan to define the gross tumor volume (GTV). The main objective of this study was to compare the inter-observer variability in RT planning between the arterial and the venous phases following intravenous contrast.</p><p><strong>Methods: </strong>PANCRINJ was a prospective monocentric study that included twenty patients with non-metastatic PC. Patients underwent a pre-therapeutic CT scan at the arterial and venous phases. The delineation of the GTV was performed by one radiologist (gold standard) and two senior radiation oncologists (operators). The primary objective was to compare the Jaccard conformity index (JCI) for the GTVs computed between the GS (gold standard) and the operators between the arterial and the venous phases with a Wilcoxon signed rank test for paired samples. The secondary endpoints were the geographical miss index (GMI), the kappa index, the intra-operator variability, and the dose-volume histograms between the arterial and venous phases.</p><p><strong>Results: </strong>The median JCI for the arterial and venous phases were 0.50 (range, 0.17-0.64) and 0.41 (range, 0.23-0.61) (p = 0.10) respectively. The median GS-GTV was statistically significantly smaller compared to the operators at the arterial (p < 0.0001) and venous phases (p < 0.001), respectively. The GMI were low with few tumors missed for all patients with a median GMI of 0.07 (range, 0-0.79) and 0.05 (range, 0-0.39) at the arterial and venous phases, respectively (p = 0.15). There was a moderate agreement between the radiation oncologists with a median kappa index of 0.52 (range 0.38-0.57) on the arterial phase, and 0.52 (range 0.36-0.57) on the venous phase (p = 0.08). The intra-observer variability for GTV delineation was lower at the venous phase than at the arterial phase for the two operators. There was no significant difference between the arterial and the venous phases regarding the dose-volume histogram for the operators.</p><p><strong>Conclusions: </strong>Our results showed inter- and intra-observer variability in delineating GTV for PC without significant differences between the arterial and the venous phases. The use of both phases should be encouraged. Our findings suggest the need to provide training for radiation oncologists in pancreatic imaging and to collaborate within a multidisciplinary team.</p>","PeriodicalId":49639,"journal":{"name":"Radiation Oncology","volume":null,"pages":null},"PeriodicalIF":3.3000,"publicationDate":"2024-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11251351/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation Oncology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s13014-024-02477-8","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The planification of radiation therapy (RT) for pancreatic cancer (PC) requires a dosimetric computed tomography (CT) scan to define the gross tumor volume (GTV). The main objective of this study was to compare the inter-observer variability in RT planning between the arterial and the venous phases following intravenous contrast.

Methods: PANCRINJ was a prospective monocentric study that included twenty patients with non-metastatic PC. Patients underwent a pre-therapeutic CT scan at the arterial and venous phases. The delineation of the GTV was performed by one radiologist (gold standard) and two senior radiation oncologists (operators). The primary objective was to compare the Jaccard conformity index (JCI) for the GTVs computed between the GS (gold standard) and the operators between the arterial and the venous phases with a Wilcoxon signed rank test for paired samples. The secondary endpoints were the geographical miss index (GMI), the kappa index, the intra-operator variability, and the dose-volume histograms between the arterial and venous phases.

Results: The median JCI for the arterial and venous phases were 0.50 (range, 0.17-0.64) and 0.41 (range, 0.23-0.61) (p = 0.10) respectively. The median GS-GTV was statistically significantly smaller compared to the operators at the arterial (p < 0.0001) and venous phases (p < 0.001), respectively. The GMI were low with few tumors missed for all patients with a median GMI of 0.07 (range, 0-0.79) and 0.05 (range, 0-0.39) at the arterial and venous phases, respectively (p = 0.15). There was a moderate agreement between the radiation oncologists with a median kappa index of 0.52 (range 0.38-0.57) on the arterial phase, and 0.52 (range 0.36-0.57) on the venous phase (p = 0.08). The intra-observer variability for GTV delineation was lower at the venous phase than at the arterial phase for the two operators. There was no significant difference between the arterial and the venous phases regarding the dose-volume histogram for the operators.

Conclusions: Our results showed inter- and intra-observer variability in delineating GTV for PC without significant differences between the arterial and the venous phases. The use of both phases should be encouraged. Our findings suggest the need to provide training for radiation oncologists in pancreatic imaging and to collaborate within a multidisciplinary team.

胰腺癌患者放疗计划中动脉和静脉相位扫描绘制靶体积的比较:PANCRINJ 研究。
背景:胰腺癌(PC)放射治疗(RT)计划的制定需要通过剂量测定计算机断层扫描(CT)来确定肿瘤总体积(GTV)。本研究的主要目的是比较静脉注射造影剂后动脉期和静脉期 RT 计划的观察者间变异性:PANCRINJ 是一项前瞻性单中心研究,共纳入 20 名非转移性 PC 患者。患者接受治疗前的动脉期和静脉期 CT 扫描。GTV的划分由一名放射科医生(金标准)和两名资深放射肿瘤科医生(操作者)共同完成。主要目的是通过配对样本的 Wilcoxon 符号秩检验,比较放射科医生(金标准)和操作者在动脉期和静脉期计算的 GTV 的 Jaccard 一致性指数(JCI)。次要终点是地理失误指数(GMI)、卡帕指数、操作员内部变异性以及动脉期和静脉期的剂量-体积直方图:动脉和静脉阶段的 JCI 中位数分别为 0.50(范围为 0.17-0.64)和 0.41(范围为 0.23-0.61)(p = 0.10)。与动脉期的操作者相比,GS-GTV 的中位数在统计学上明显更小(p 结论:GS-GTV 的中位数在统计学上明显更小):我们的研究结果表明,在划定 PC 的 GTV 时,观察者之间和观察者内部存在差异,但动脉期和静脉期之间无明显差异。应鼓励同时使用这两个阶段。我们的研究结果表明,有必要对放射肿瘤专家进行胰腺成像方面的培训,并在多学科团队中开展合作。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Radiation Oncology
Radiation Oncology ONCOLOGY-RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
CiteScore
6.50
自引率
2.80%
发文量
181
审稿时长
3-6 weeks
期刊介绍: Radiation Oncology encompasses all aspects of research that impacts on the treatment of cancer using radiation. It publishes findings in molecular and cellular radiation biology, radiation physics, radiation technology, and clinical oncology.
文献相关原料
公司名称 产品信息 采购帮参考价格
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信