Utility of an Externalized Temporary Transvenous Implantable Cardioverter-defibrillator System in the Setting of Ventricular Tachycardia Storm and Concurrent Device Infection Requiring Extraction.

Q3 Medicine
Journal of Innovations in Cardiac Rhythm Management Pub Date : 2024-07-15 eCollection Date: 2024-07-01 DOI:10.19102/icrm.2024.15071
Ronuk M Modi, Marianna Lozano Cruz Marquez, Shu Yang, Robert N D'Angelo, Timothy R Maher, Bahij Kreidieh, Nicholas O Palmeri, Hans F Stabenau, Dana Goldense, Emily Wacks, Patricia Tung, Andre d'Avila, Jonathan Waks, Peter Zimetbaum, Andrew H Locke
{"title":"Utility of an Externalized Temporary Transvenous Implantable Cardioverter-defibrillator System in the Setting of Ventricular Tachycardia Storm and Concurrent Device Infection Requiring Extraction.","authors":"Ronuk M Modi, Marianna Lozano Cruz Marquez, Shu Yang, Robert N D'Angelo, Timothy R Maher, Bahij Kreidieh, Nicholas O Palmeri, Hans F Stabenau, Dana Goldense, Emily Wacks, Patricia Tung, Andre d'Avila, Jonathan Waks, Peter Zimetbaum, Andrew H Locke","doi":"10.19102/icrm.2024.15071","DOIUrl":null,"url":null,"abstract":"<p><p>With the expanding use of cardiac implantable electronic device (CIED) therapy, intravascular device infections are becoming more common. In the case of transvenous implantable cardioverter-defibrillator (ICD) infections requiring extraction for bacterial clearance, there remains no standard method to deliver temporary ICD therapy following device removal. We present a case of persistent bacteremia complicated by monomorphic ventricular tachycardia (VT) electrical storm where biventricular ICD system extraction was performed and a temporary transvenous dual-coil lead with an externalized ICD generator was used to treat VT episodes prior to the re-implantation of a new permanent system. This case demonstrates the utility of a temporary externalized transvenous ICD system in the successful detection and pace-termination of VT, thereby reducing episodes of painful and potentially harmful external defibrillator shocks during the treatment of CIED infection.</p>","PeriodicalId":36299,"journal":{"name":"Journal of Innovations in Cardiac Rhythm Management","volume":"15 7","pages":"5930-5934"},"PeriodicalIF":0.0000,"publicationDate":"2024-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11238887/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Innovations in Cardiac Rhythm Management","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.19102/icrm.2024.15071","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

With the expanding use of cardiac implantable electronic device (CIED) therapy, intravascular device infections are becoming more common. In the case of transvenous implantable cardioverter-defibrillator (ICD) infections requiring extraction for bacterial clearance, there remains no standard method to deliver temporary ICD therapy following device removal. We present a case of persistent bacteremia complicated by monomorphic ventricular tachycardia (VT) electrical storm where biventricular ICD system extraction was performed and a temporary transvenous dual-coil lead with an externalized ICD generator was used to treat VT episodes prior to the re-implantation of a new permanent system. This case demonstrates the utility of a temporary externalized transvenous ICD system in the successful detection and pace-termination of VT, thereby reducing episodes of painful and potentially harmful external defibrillator shocks during the treatment of CIED infection.

外置临时经静脉植入式心律转复除颤器系统在室性心动过速风暴和需要拔除的并发设备感染情况下的实用性。
随着心脏植入式电子设备(CIED)治疗应用的不断扩大,血管内设备感染变得越来越常见。在经静脉植入式心律转复除颤器(ICD)感染需要拔除以清除细菌的情况下,目前仍没有标准方法在设备拔除后提供临时 ICD 治疗。我们介绍了一例持续性菌血症并发单形室速(VT)电风暴的病例,在该病例中,我们对双心室 ICD 系统进行了摘除,并在重新植入新的永久性系统之前,使用带有外置 ICD 发生器的临时经静脉双线圈导联治疗 VT 发作。该病例证明了临时外置经静脉 ICD 系统在成功检测和终止 VT 方面的作用,从而减少了在治疗 CIED 感染期间外部除颤器冲击带来的痛苦和潜在危害。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Innovations in Cardiac Rhythm Management
Journal of Innovations in Cardiac Rhythm Management Medicine-Cardiology and Cardiovascular Medicine
CiteScore
1.50
自引率
0.00%
发文量
70
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信