{"title":"Correction to ‘Serum neurofilament light chain measurements following nerve trauma’","authors":"","doi":"10.1111/jns.12642","DOIUrl":null,"url":null,"abstract":"<p>Wilcox M, Rayner MLD, Guillemot-Legris O, Platt I, Brown H, Quick T, Phillips JB Serum neurofilament light chain measurements following nerve trauma. J Peripher Nerv Syst. 2023;28(3):500–507. doi:10.1111/jns.12576</p><p>There was an error in the analysis of serum NfL data that resulted in the values in Figure 1, Table 1 and Results being expressed incorrectly as 40-fold lower than their correct concentration. The ‘Serum NfL analysis’ section of the Methods should read ‘Serum NfL concentration was measured using the Simoa HD-X Analyser (Quanterix, Billerica, MA) with a Neurology 4-plex B kit (item number: 103345). All samples were randomised across the plates and run in duplicate. All samples measured were above the lower limit of detection (0.0962 pg/mL) with a mean coefficient of variation of 13.2% between duplicates. Intra- and inter-plate coefficients of variation, monitored using 2-4 pooled human internal control samples across each plate, were <10%’. not ‘NfL levels in serum were measured using a SIMOA® SR-X analyser (Quanterix Corporation, Massachusetts) with a SIMOA® NF-light Advantage (SR-X) Kit (Quanterix, No. 103400) according to protocols well described elsewhere (O'Brien, et al., 2021). All samples were run in duplicate and analysers were blinded to the experimental conditions. All samples measured above the lower limit of detection (0.038 pg/mL) with a mean coefficient of variation of 9.15% between duplicates. Furthermore, two control samples were run on each place with a mean coefficient of variation of 6.90%’.</p><p>New versions of Figure 1 and Table 1 have been provided. In addition, the second line of the Results section should read 20.33 ± 8.98 pg/mL rather than 0.50 ± 0.2 pg/mL. The third line of the Discussion section should read 20 pg/mL rather than 0.50 pg/mL.</p><p>We apologise for this error.</p>","PeriodicalId":17451,"journal":{"name":"Journal of the Peripheral Nervous System","volume":"29 3","pages":"376-377"},"PeriodicalIF":3.9000,"publicationDate":"2024-07-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/jns.12642","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Peripheral Nervous System","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/jns.12642","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Wilcox M, Rayner MLD, Guillemot-Legris O, Platt I, Brown H, Quick T, Phillips JB Serum neurofilament light chain measurements following nerve trauma. J Peripher Nerv Syst. 2023;28(3):500–507. doi:10.1111/jns.12576
There was an error in the analysis of serum NfL data that resulted in the values in Figure 1, Table 1 and Results being expressed incorrectly as 40-fold lower than their correct concentration. The ‘Serum NfL analysis’ section of the Methods should read ‘Serum NfL concentration was measured using the Simoa HD-X Analyser (Quanterix, Billerica, MA) with a Neurology 4-plex B kit (item number: 103345). All samples were randomised across the plates and run in duplicate. All samples measured were above the lower limit of detection (0.0962 pg/mL) with a mean coefficient of variation of 13.2% between duplicates. Intra- and inter-plate coefficients of variation, monitored using 2-4 pooled human internal control samples across each plate, were <10%’. not ‘NfL levels in serum were measured using a SIMOA® SR-X analyser (Quanterix Corporation, Massachusetts) with a SIMOA® NF-light Advantage (SR-X) Kit (Quanterix, No. 103400) according to protocols well described elsewhere (O'Brien, et al., 2021). All samples were run in duplicate and analysers were blinded to the experimental conditions. All samples measured above the lower limit of detection (0.038 pg/mL) with a mean coefficient of variation of 9.15% between duplicates. Furthermore, two control samples were run on each place with a mean coefficient of variation of 6.90%’.
New versions of Figure 1 and Table 1 have been provided. In addition, the second line of the Results section should read 20.33 ± 8.98 pg/mL rather than 0.50 ± 0.2 pg/mL. The third line of the Discussion section should read 20 pg/mL rather than 0.50 pg/mL.
期刊介绍:
The Journal of the Peripheral Nervous System is the official journal of the Peripheral Nerve Society. Founded in 1996, it is the scientific journal of choice for clinicians, clinical scientists and basic neuroscientists interested in all aspects of biology and clinical research of peripheral nervous system disorders.
The Journal of the Peripheral Nervous System is a peer-reviewed journal that publishes high quality articles on cell and molecular biology, genomics, neuropathic pain, clinical research, trials, and unique case reports on inherited and acquired peripheral neuropathies.
Original articles are organized according to the topic in one of four specific areas: Mechanisms of Disease, Genetics, Clinical Research, and Clinical Trials.
The journal also publishes regular review papers on hot topics and Special Issues on basic, clinical, or assembled research in the field of peripheral nervous system disorders. Authors interested in contributing a review-type article or a Special Issue should contact the Editorial Office to discuss the scope of the proposed article with the Editor-in-Chief.